OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.23.1Nodegx2LitepsDescriptor
1.3.6.1.4.1.1166.6.1.2.23.1NodetrapLitepsConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.23.2Tablegx2LitepsAnalogTablenot-accessiblemandatoryThis table contains gx2Liteps specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.23.2NodetrapLitepsConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.23.2.1Rowgx2LitepsAnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.23.2.1.1Columngx2LitepsAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.23.2.1.2Columnlitepslabel12Voltread-onlyoptionalThe value of this object provides the label of the 12 Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.3Columnlitepsuom12Voltread-onlyoptionalThe value of this object provides the unit of measure of the 12 Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.4ColumnlitepsmajorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.23.2.1.5ColumnlitepsmajorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.6ColumnlitepsminorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.23.2.1.7ColumnlitepsminorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.8ColumnlitepscurrentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bi…
1.3.6.1.4.1.1166.6.1.2.23.2.1.9ColumnlitepsstateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
1.3.6.1.4.1.1166.6.1.2.23.2.1.10ColumnlitepsminValue12Voltread-onlymandatoryThe value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.23.2.1.11ColumnlitepsmaxValue12Voltread-onlymandatoryThe value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.23.2.1.12ColumnlitepsalarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12 Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.13Columnlitepslabel5Voltread-onlyoptionalThe value of this object provides the label of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.14Columnlitepsuom5Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 5 Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.15ColumnlitepsmajorHigh5Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.16ColumnlitepsmajorLow5Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.17ColumnlitepsminorHigh5Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.18ColumnlitepsminorLow5Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.19ColumnlitepscurrentValue5Voltread-onlymandatoryThe value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit…
1.3.6.1.4.1.1166.6.1.2.23.2.1.20ColumnlitepsstateFlag5Voltread-onlymandatoryThe value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.23.2.1.21ColumnlitepsminValue5Voltread-onlymandatoryThe value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.22ColumnlitepsmaxValue5Voltread-onlymandatoryThe value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.23.2.1.23ColumnlitepsalarmState5Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 5 Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.24Columnlitepslabel3Voltread-onlyoptionalThe value of this object provides the label of the 3 Anode Volt Analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.25Columnlitepsuom3Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.2.1.26ColumnlitepsmajorHigh3Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.23.2.1.27ColumnlitepsmajorLow3Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.23.2.1.28ColumnlitepsminorHigh3Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.23.2.1.29ColumnlitepsminorLow3Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.23.2.1.30ColumnlitepscurrentValue3Voltread-onlymandatoryThe value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.23.2.1.31ColumnlitepsstateFlag3Voltread-onlymandatoryThe value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.23.2.1.32ColumnlitepsminValue3Voltread-onlymandatoryThe value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.23.2.1.33ColumnlitepsmaxValue3Voltread-onlymandatoryThe value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.23.2.1.34ColumnlitepsalarmState3Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter.
1.3.6.1.4.1.1166.6.1.2.23.3Tablegx2LitepsStatusTablenot-accessiblemandatoryThis table contains gx2Liteps specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.23.3NodetrapLitepsFanCurrent1This trap is issued when Fan 1 is in an alarm condition.
1.3.6.1.4.1.1166.6.1.2.23.3.2Rowgx2LitepsStatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.23.3.2.1Columngx2LitepsStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.23.3.2.2ColumnlitepslabelFan1Statusread-onlyoptionalThe value of this object provides the label of the Fan 1 Status parameter.
1.3.6.1.4.1.1166.6.1.2.23.3.2.3ColumnlitepsvalueFan1Statusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.23.3.2.4ColumnlitepsstateflagFan1Statusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.23.3.2.5ColumnlitepslabelFan2Statusread-onlyoptionalThe value of this object provides the label of the Fan 2 Status parameter.
1.3.6.1.4.1.1166.6.1.2.23.3.2.6ColumnlitepsvalueFan2Statusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.23.3.2.7ColumnlitepsstateflagFan2Statusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.23.4NodetrapLitepsFanCurrent2This trap is issued when Fan 2 is in an alarm condition.
1.3.6.1.4.1.1166.6.1.2.23.5NodetrapLiteps12VoltThis trap is issued when the 12 Volts is in an alarm condition.
1.3.6.1.4.1.1166.6.1.2.23.6NodetrapLiteps5VoltThis trap is issued when the 5.1 Volts is in an alarm condition.
1.3.6.1.4.1.1166.6.1.2.23.7NodetrapLiteps3VoltThis trap is issued when the 3.7 Volts is in an alarm condition.