MIB Viewer

OPTIX-RTN-MIMO-MGR-MIB

108 objects
This module is used to configure and query IF board related parameters required in radio link configuration and preventive maintenance, including the IF board modulation mode, bandwidth, AM management, and link identifier.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.4.40.6IdentityoptixRtnMimoParaMgrThis module is used to configure and query IF board related parameters required in radio link configuration and preventive maintenance, including the IF board …
1.3.6.1.2.1.10.4.40.6.10NodeoptixRtnMimoPara
1.3.6.1.2.1.10.4.40.6.10.240TableoptixRtnMimo4P4GroupTablenot-accessiblecurrentIndicates the MIMO work group
1.3.6.1.2.1.10.4.40.6.10.240.1RowoptixRtnMimo4P4GroupEntrynot-accessiblecurrentIndicates the MIMO work group
1.3.6.1.2.1.10.4.40.6.10.240.1.1ColumnoptixRtnGroupIDnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.2ColumnoptixRtnGroupTyperead-createcurrentIndicates the MIMO work group type
1.3.6.1.2.1.10.4.40.6.10.240.1.3ColumnoptixRtnNePos4P1read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.240.1.4ColumnoptixRtnBoardID4P1read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.5ColumnoptixRtnSubCardID4P1read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.6ColumnoptixRtnPortID4P1read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.7ColumnoptixRtnPolar4P1read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.240.1.8ColumnoptixRtnNePos4P2read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.240.1.9ColumnoptixRtnBoardID4P2read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.10ColumnoptixRtnSubCardID4P2read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.11ColumnoptixRtnPortID4P2read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.12ColumnoptixRtnPolar4P2read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.240.1.13ColumnoptixRtnNePos4P3read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.240.1.14ColumnoptixRtnBoardID4P3read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.15ColumnoptixRtnSubCardID4P3read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.16ColumnoptixRtnPortID4P3read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.17ColumnoptixRtnPolar4P3read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.240.1.18ColumnoptixRtnNePos4P4read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.240.1.19ColumnoptixRtnBoardID4P4read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.20ColumnoptixRtnSubCardID4P4read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.21ColumnoptixRtnPortID4P4read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.240.1.22ColumnoptixRtnPolar4P4read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.240.1.23ColumnoptixRtnMimoIfDelAdjNePgread-createcurrentIndicates whether to delete configurations of the adjacent NE. 0: false 1: true
1.3.6.1.2.1.10.4.40.6.10.250TableoptixRtnMimo2P2GroupTablenot-accessiblecurrentIndicates the MIMO work group
1.3.6.1.2.1.10.4.40.6.10.250.1RowoptixRtnMimo2P2GroupEntrynot-accessiblecurrentIndicates the MIMO work group
1.3.6.1.2.1.10.4.40.6.10.250.1.1ColumnoptixRtn2P2GroupIDnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.2ColumnoptixRtn2P2GroupTyperead-createcurrentIndicates the MIMO work group type
1.3.6.1.2.1.10.4.40.6.10.250.1.3ColumnoptixRtnNePos2P1read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.250.1.4ColumnoptixRtnBoardID2P1read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.5ColumnoptixRtnSubCardID2P1read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.6ColumnoptixRtnPortID2P1read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.7ColumnoptixRtnPolar2P1read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.250.1.8ColumnoptixRtnNePos2P2read-createcurrentIndicates the local or peer end. 1: local 2: neighbour
1.3.6.1.2.1.10.4.40.6.10.250.1.9ColumnoptixRtnBoardID2P2read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.10ColumnoptixRtnSubCardID2P2read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.11ColumnoptixRtnPortID2P2read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.250.1.12ColumnoptixRtnPolar2P2read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.250.1.13ColumnoptixRtnIfDelAdjNePgread-createcurrentIndicates whether to delete configurations of the adjacent NE. 0: false 1: true
1.3.6.1.2.1.10.4.40.6.10.260TableoptixRtnMimoOduTablenot-accessiblecurrentIndicates the configuration for ODUs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.260.1RowoptixRtnMimoOduEntrynot-accessiblecurrentIndicates the configuration for ODUs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.260.1.1ColumnoptixRtnMimoGroupNumnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.260.1.2ColumnoptixRtnMimoOduMaxTSLread-createcurrentIndicates the maximum transmit power of an ODU.
1.3.6.1.2.1.10.4.40.6.10.260.1.3ColumnoptixRtnMimoOduTxFreqread-createcurrentIndicates the transmit frequency in the unit of KHz.
1.3.6.1.2.1.10.4.40.6.10.260.1.4ColumnoptixRtnMimoOduTxPowerread-createcurrentIndicates the transmit power of the ODU.
1.3.6.1.2.1.10.4.40.6.10.260.1.5ColumnoptixRtnMimoOduWorkStateread-createcurrentIndicates whether the ODU is muted or unmated.
1.3.6.1.2.1.10.4.40.6.10.260.1.6ColumnoptixRtnMimoOduTRSpacingread-createcurrentIndicates the T/R spacing for the ODU.
1.3.6.1.2.1.10.4.40.6.10.270TableoptixRtnMimoIfAtribTablenot-accessiblecurrentIndicates the configuration for a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.270.1RowoptixRtnMimoIfAtribEntrynot-accessiblecurrentIndicates the configuration for a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.270.1.1ColumnoptixRtnMimoGPIndexnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.270.1.2ColumnoptixRtnMimoBandWidthread-createcurrentIndicates the channel bandwidth.
1.3.6.1.2.1.10.4.40.6.10.270.1.3ColumnoptixRtnMimoAcmEnread-createcurrentIndicates whether the ACM function is enabled. 0: disable 1: enable default:enable
1.3.6.1.2.1.10.4.40.6.10.270.1.4ColumnoptixRtnMimoBottomModread-createcurrentIndicates the guaranteed-capacity mode.
1.3.6.1.2.1.10.4.40.6.10.270.1.5ColumnoptixRtnMimoPeakModread-createcurrentIndicates the full-capacity mode.
1.3.6.1.2.1.10.4.40.6.10.270.1.6ColumnoptixRtnMimoManualModread-createcurrentIndicate the manually-specified-capacity mode.
1.3.6.1.2.1.10.4.40.6.10.270.1.7ColumnoptixRtnMimoAtpcEnread-createcurrentIndicates whether the ATPC function is enabled in a MIMO work group. 0: Disable 1: Enable
1.3.6.1.2.1.10.4.40.6.10.290TableoptixRtnMimoXPITablenot-accessiblecurrentIndicates to query the XPI value
1.3.6.1.2.1.10.4.40.6.10.290.1RowoptixRtnMimoXPIEntrynot-accessiblecurrentIndicates to query the XPI value
1.3.6.1.2.1.10.4.40.6.10.290.1.1ColumnoptixRtnXPIBoardIDread-writecurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.290.1.2ColumnoptixRtnOffsideNeIDread-writecurrentIndicates the peer NE ID.
1.3.6.1.2.1.10.4.40.6.10.290.1.3ColumnoptixRtnOffsideNeBidread-writecurrentIndicates the slot ID of a board on the peer NE.
1.3.6.1.2.1.10.4.40.6.10.290.1.4ColumnoptixRtnXPIValueread-onlycurrentIndicates the XPI value
1.3.6.1.2.1.10.4.40.6.10.300TableoptixRtnMimo2P2SyncCfgTablenot-accessiblecurrentIndicates to synchronize MIMO configurations of the local NE to the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.300.1RowoptixRtnMimo2P2SyncCfgEntrynot-accessiblecurrentIndicates to synchronize MIMO configurations of the local NE to the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.300.1.1ColumnoptixRtn2P2SyncCfgGroupIDnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.300.1.2ColumnoptixRtnSyncCfgBoardIDread-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.300.1.3ColumnoptixRtnSyncCfgSubCardIDread-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.300.1.4ColumnoptixRtnSyncCfgPortIDread-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.300.1.5ColumnoptixRtnSyncCfgPolarread-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.310TableoptixRtnMimo4P4SyncCfgTablenot-accessiblecurrentIndicates to synchronize MIMO configurations of the local NE to the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.310.1RowoptixRtnMimo4P4SyncCfgEntrynot-accessiblecurrentIndicates to synchronize MIMO configurations of the local NE to the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.310.1.1ColumnoptixRtn4P4SyncCfgGroupIDnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.2ColumnoptixRtnSyncCfgBoardID2P1read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.3ColumnoptixRtnSyncCfgSubCardID2P1read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.4ColumnoptixRtnSyncCfgPortID2P1read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.5ColumnoptixRtnSyncCfgPolar2P1read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.310.1.6ColumnoptixRtnSyncCfgBoardID2P2read-createcurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.7ColumnoptixRtnSyncCfgSubCardID2P2read-createcurrentIndicates the subboard ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.8ColumnoptixRtnSyncCfgPortID2P2read-createcurrentIndicates the port ID.
1.3.6.1.2.1.10.4.40.6.10.310.1.9ColumnoptixRtnSyncCfgPolar2P2read-createcurrentIndicates the polarization direction. 1: h1 2: v1 3: h2 4: v2
1.3.6.1.2.1.10.4.40.6.10.320TableoptixRtnMimoAdjoinNeinfoTablenot-accessiblecurrentIndicates to query the cascading NEs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.320.1RowoptixRtnMimoAdjoinNeinfoEntrynot-accessiblecurrentIndicates to query the cascading NEs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.320.1.1ColumnoptixRtnMimoNeighbourNeIDread-onlycurrentIndicates the ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.320.1.2ColumnoptixRtnMimoNeighbourNENameread-onlycurrentIndicates the name of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.320.1.3ColumnoptixRtnMimoNeighbourNEBoardTyperead-onlycurrentIndicates board type of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321TableoptixRtnMimoAdjoinExtNeinfoTablenot-accessiblecurrentIndicates to query the cascading NEs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.321.1RowoptixRtnMimoAdjoinExtNeinfoEntrynot-accessiblecurrentIndicates to query the cascading NEs in a MIMO work group
1.3.6.1.2.1.10.4.40.6.10.321.1.1ColumnoptixRtnMimoGroupIDnot-accessiblecurrentIndicates the MIMO work group ID.
1.3.6.1.2.1.10.4.40.6.10.321.1.2ColumnoptixRtnMimoNeBoardIDread-onlycurrentIndicates the slot ID of the NE
1.3.6.1.2.1.10.4.40.6.10.321.1.3ColumnoptixRtnMimoNeSubCardIDread-onlycurrentIndicates the subboard ID of the NE
1.3.6.1.2.1.10.4.40.6.10.321.1.4ColumnoptixRtnMimoNePortIDread-onlycurrentIndicates the port ID of the NE
1.3.6.1.2.1.10.4.40.6.10.321.1.5ColumnoptixRtnMimoNeighbourNeIdread-onlycurrentIndicates the ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.6ColumnoptixRtnMimoNeighbourNeNameread-onlycurrentIndicates the name of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.7ColumnoptixRtnMimoNeighbourNeBoardTyperead-onlycurrentIndicates board type of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.8ColumnoptixRtnMimoNeighbourNeADJIDread-onlycurrentIndicates the mimo ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.9ColumnoptixRtnMimoNeighbourNeBoardIDread-onlycurrentIndicates the slot ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.10ColumnoptixRtnMimoNeighbourNeSubCardIDread-onlycurrentIndicates the subboard ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.321.1.11ColumnoptixRtnMimoNeighbourNePortIDread-onlycurrentIndicates the port ID of the adjacent NE
1.3.6.1.2.1.10.4.40.6.10.330TableoptixRtnMimoXPIExtTablenot-accessiblecurrentIndicates to query the XPI value
1.3.6.1.2.1.10.4.40.6.10.330.1RowoptixRtnMimoXPIExtEntrynot-accessiblecurrentIndicates to query the XPI value
1.3.6.1.2.1.10.4.40.6.10.330.1.1ColumnoptixRtnXPIExtBoardIDIndexnot-accessiblecurrentIndicates the slot ID.
1.3.6.1.2.1.10.4.40.6.10.330.1.2ColumnoptixRtnXPIValueExtread-onlycurrentIndicates the XPI Ext value
Type Definitions
NameSyntaxStatusDescription
OPTIXRtnBoardTypeINTEGER { shxa2(2454), shuf3(2484), v1shua2(3343), mxuf4(3344), sxa3(3372), dmc5a(3415), dmc4b(3416), mxui5(3442) }currentDescribes the board type of peer NE,shxa2: 2454,shuf3: 2484,v1shua2: 3343,mxuf4: 3344,sxa3: 3372,dmc5a: 3415,dmc4b: 3416,mxui5: 3442
OPTIXRtnMimoBandWidthTypeINTEGER { bw28M(4), bw40M(5), bw56M(6), bw28MACCP(31), bw56MACCP(32), }currentIndicates the IF bandwidth supported by MIMO.
OPTIXRtnModulateModeTypeINTEGER { modeClear(0), modeQPSK(1), mode16QAM(2), mode32QAM(3), mode64QAM(4), mode128QAM(5), mode256QAM(6), mode512QAM(7), mode1024QAM(8), modeQPSKSTRONG(9), mode16QAMSTRONG(10), mode1024QAMLIGHT(12), mode2048QAM(13), mode4096QAM(20), modeNULL(-1) }currentDescribes the modulation mode supported by an IF board. Values: 1: QPSK 2: 16QAM 3: 32QAM 4: 64QAM 5: 128QAM 6: 256QAM 22: BPSK250M 23: BPSK500M 24: BPSK750M 25: BPSK1000M 26: BPSK1500M 27: BPSK2000M -1: null