MIB Viewer
MIB Viewer Desktop New

SWITCH-CPUPRO-MIB

15 objects
The MIB module is for configuration of Cpu Protection feature.
Imported Objects
RAISECOM-BASE-MIBiscomSwitch
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SWITCH-TCEnableVar
OIDNameAccessStatusDescription
1.3.6.1.4.1.8886.6.1.60IdentityrcCpuProThe MIB module is for configuration of Cpu Protection feature.
1.3.6.1.4.1.8886.6.1.60.1NodercCpuProGroup
1.3.6.1.4.1.8886.6.1.60.1.1TablercCpuProPortTablenot-accessiblecurrentA table provides the status of the cpu protection in per port.
1.3.6.1.4.1.8886.6.1.60.1.1.1RowrcCpuProPortEntrynot-accessiblecurrentTable entry for cpu protection status in per port.
1.3.6.1.4.1.8886.6.1.60.1.1.1.1ColumnrcCpuProPortIndexnot-accessiblecurrentAn index that uniquely identifies a configuration about cpu pro. Eg:for iscom2826/2826e,the value range is from 1 to 26, for iscom2812gf, from 1 to 12, for isc…
1.3.6.1.4.1.8886.6.1.60.1.1.1.2ColumnrcCpuProPortPacketEnableread-writecurrentEnable or disable cpu pro for arp, bpdu or icmp flood for the port
1.3.6.1.4.1.8886.6.1.60.1.1.1.3ColumnrcCpuProPortPacketAttackStatusread-onlycurrentThis object specifies if the packet is attacking the cpu.
1.3.6.1.4.1.8886.6.1.60.1.1.1.4ColumnrcCpuProPortPacketAttackedCountread-onlycurrentThis object specifies the totle number of special packet attacked the cpu.
1.3.6.1.4.1.8886.6.1.60.1.2TablercCpuProPacketTablenot-accessiblecurrentA table provides the mechanism to control cpu protection with per packet type.
1.3.6.1.4.1.8886.6.1.60.1.2.1RowrcCpuProPacketEntrynot-accessiblecurrentTable entry for cpu protection config based on port.
1.3.6.1.4.1.8886.6.1.60.1.2.1.1ColumnrcCpuProPacketIndexread-onlycurrentThis object specifies which packet type the entry information belongs to, under the port.
1.3.6.1.4.1.8886.6.1.60.1.2.1.2ColumnrcCpuProPacketIntervalread-writecurrentThis object specifies the sample interval for special packet.
1.3.6.1.4.1.8886.6.1.60.1.2.1.3ColumnrcCpuProPacketHighread-writecurrentIf the number of packets received exceeds the high threshold value, the relative packet will be denied.
1.3.6.1.4.1.8886.6.1.60.1.2.1.4ColumnrcCpuProPacketLowread-writecurrentAfter the cpu was attacked, If the number of packets received is under the low threshold value, the relative packet will be received not denied.
1.3.6.1.4.1.8886.6.1.60.1.2.1.5ColumnrcCpuProPacketActionread-onlycurrentThis object specifies which atction the CPUpro will take after be attacked.