X25-MIB
144 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1978 | Nodengcan | |||
| 1.3.6.1.4.1.1978.2 | Nodetiger | |||
| 1.3.6.1.4.1.1978.2.14 | Nodex25MIB | |||
| 1.3.6.1.4.1.1978.2.14.1 | Nodex25L3 | |||
| 1.3.6.1.4.1.1978.2.14.1.1 | Tablex25AdmnTable | not-accessible | mandatory | This table contains configuration, channel assignments and statistics for an X.25 Packet Level Entity (PLE). The values are as last set by the administrator an… |
| 1.3.6.1.4.1.1978.2.14.1.1.1 | Rowx25AdmnEntry | not-accessible | mandatory | Entries of x25AdmnTable. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.1 | Columnx25AdmnIndex | read-write | mandatory | The ifIndex value for the X.25 Interface. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.2 | Columnx25AdmnInterfaceMode | read-write | mandatory | Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.3 | Columnx25AdmnPacketSequencing | read-write | mandatory | The modulus of the packet sequence number space. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.4 | Columnx25AdmnRestartTimer | read-write | mandatory | The T20 restart timer in milliseconds. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.5 | Columnx25AdmnCallTimer | read-write | mandatory | The T21 Call timer in milliseconds. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.6 | Columnx25AdmnResetTimer | read-write | mandatory | The T22 Reset timer in milliseconds. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.7 | Columnx25AdmnClearTimer | read-write | mandatory | The T23 Clear timer in milliseconds. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.8 | Columnx25AdmnWindowTimer | read-write | mandatory | The T24 window status transmission timer in milliseconds. A value of 0 indicates no window timer in use. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.9 | Columnx25AdmnDataRxmtTimer | read-write | mandatory | The T25 data retransmission timer in milliseconds. A value of 0 indicates no data retransmission timer in use. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.10 | Columnx25AdmnInterruptTimer | read-write | mandatory | The T26 interrupt timer in milliseconds. A value of 0 indicates no interrupt timer in use. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.11 | Columnx25AdmnRejectTimer | read-write | mandatory | The T27 Reject retransmission timer in milliseconds. A value of 0 indicates no reject timer in use. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.12 | Columnx25AdmnRegistrationRequestTimer | read-write | mandatory | The T28 registration timer in milliseconds. A value of 0 indicates no registration timer in use. UNITS: milliseconds |
| 1.3.6.1.4.1.1978.2.14.1.1.1.13 | Columnx25AdmnRestartCount | read-write | mandatory | The R20 restart retransmission count. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.14 | Columnx25AdmnResetCount | read-write | mandatory | The r22 Reset retransmission count. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.15 | Columnx25AdmnClearCount | read-write | mandatory | The r23 Clear retransmission count. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.16 | Columnx25AdmnDataRxmtCount | read-write | mandatory | The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.17 | Columnx25AdmnRejectCount | read-write | mandatory | The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.18 | Columnx25AdmnRegistrationRequestCount | read-write | mandatory | The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.19 | Columnx25AdmnNumberPVCs | read-write | mandatory | The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number. Set to 0 for no PVCs. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.20 | Columnx25AdmnDefCallParamId | read-write | mandatory | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.21 | Columnx25AdmnProtocolVersionSupported | read-write | mandatory | Identifies the version of the X.25 protocol this interface should support. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.22 | Columnx25AdmnRegistrationMode | read-write | mandatory | Defines how registration exchanges are handled. A value of auto indicates that the DTE always sends empty request at connection time and that a DCE automatical… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.23 | Columnx25AdmnDiagnosticMode | read-write | mandatory | Controls the generation of diagnostic packets. A value of standard means send diagnostics if configured as a DCE only, as per CCITT specification. A value of o… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.24 | Columnx25AdmnInterruptSize | read-write | mandatory | Defines the maximum user data size in interrupt packets. Use 1 for networks compliant with 1980 CCITT recommendation and before, use 32 for 1984 and later comp… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.25 | Columnx25AdmnMaxTxWindow | read-write | mandatory | Specifies the maximum transmit window size that can be negotiated. 1 through 7 for modulo 8. 1 through 128 for modulo 128. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.26 | Columnx25AdmnMaxRxWindow | read-write | mandatory | Specifies the maximum receive window size that can be negotiated. 1 through 7 for modulo 8. 1 through 128 for modulo 128. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.27 | Columnx25AdmnFacilityLength | read-write | mandatory | Defines the maximum length of the Facility field. Use 63 for 1980 or earlier complience. Use 109 for 1984 and later compliant networks. Other value are used on… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.28 | Columnx25AdmnCallDataSize | read-write | mandatory | Defines the maximum length of the user data in call request/indication packets when fast select not used. Use 16 for CCITT complience. Other value are used onl… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.29 | Columnx25AdmnFastSelectCallDataSize | read-write | mandatory | Defines the maximum length of the user data in call request/indication packets when fast select is used. Use 128 for CCITT complience. Other value are used onl… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.30 | Columnx25AdmnExtendedClear | read-write | mandatory | Controls support for extended clear format (allow addresses and facilities in clear/clear cf packets). A value of on means that the extended clear format is su… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.31 | Columnx25AdmnCause | read-write | mandatory | Controls how a cause field from the user is converted. A value of asis means send the user cause as is. A value of ccitt-80 means convert to 1980 format (clear… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.32 | Columnx25AdmnABit | read-write | mandatory | x25AdmnABit defines how long addresses, (up to 17 digits,) are handled. A value of on, means always use the long address format. A value of off, means always u… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.33 | Columnx25AdmnRRTrigger | read-write | mandatory | This defines when the frame level sends RR. 0: Only send RR when the window is full. Very inefficient as it always causes the remote to enter flow control situ… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.34 | Columnx25AdmnRRTimer | read-write | mandatory | This x25AdmnRRTimer only causes the transmission of an RR Packet when there are outstanding packets to acknowledge to the remote. When the transmission of RR p… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.35 | Columnx25AdmnRRPiggy | read-write | mandatory | This specifies whether the frame level can 'piggyback' acknowledgements in I frames. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.36 | Columnx25AdmnTxRejectMode | read-write | mandatory | Defines how packet level handles the reception of out of sequence data packets. A value of reset will reset the virtual circuit. A value of rejectReset will se… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.37 | Columnx25AdmnRxRejectMode | read-write | mandatory | Defines how packet level handles the reception of reject packets. A value of reset will reset the virtual circuit. A value of retxReset will retransmit packets… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.38 | Columnx25AdmnDBit | read-write | mandatory | Defines how packet level handles the D bit. A value of no indicates that the use of the D bit not allowed. A value of ok indicates that the use of the D bit is… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.39 | Columnx25AdmnR28Action | read-write | mandatory | Selects the packet level action after R28 expirations of the registration timer T28. A value of fail means the link is considered as non operational and is dis… |
| 1.3.6.1.4.1.1978.2.14.1.1.1.40 | Columnx25ChannelLIC | read-write | mandatory | Lowest Incoming channel. A value of 0 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.41 | Columnx25ChannelHIC | read-write | mandatory | Highest Incoming channel. A value of 4095 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.42 | Columnx25ChannelLTC | read-write | mandatory | Lowest Two-way channel. A value of 0 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.43 | Columnx25ChannelHTC | read-write | mandatory | Highest Two-way channel. A value of 0 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.44 | Columnx25ChannelLOC | read-write | mandatory | Lowest outgoing channel. A value of 0 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.45 | Columnx25ChannelHOC | read-write | mandatory | Highest outgoing channel. A value of 0 indicates that no LCN is available. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.46 | Columnx25StatInCalls | read-only | mandatory | The number of Call Request/Indication packets received. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.47 | Columnx25StatInCallRefusals | read-only | mandatory | The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast … |
| 1.3.6.1.4.1.1978.2.14.1.1.1.48 | Columnx25StatInProviderInitiatedClears | read-only | mandatory | The number of Clear Request/Indication packets sent. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.49 | Columnx25StatInRemotelyInitiatedResets | read-only | mandatory | The number of Reset Request/Indication packets received. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.50 | Columnx25StatInProviderInitiatedResets | read-only | mandatory | The number of Reset Request/Indication packets sent. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.51 | Columnx25StatInRestarts | read-only | mandatory | The number of Restart Request/Indication packets received. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.52 | Columnx25StatInDataPackets | read-only | mandatory | The number of data packets received. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.53 | Columnx25StatInAccusedOfProtocolErrors | read-only | mandatory | The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.54 | Columnx25StatInInterrupts | read-only | mandatory | The number of interrupt packets received by the PLE or over the PVC/VC. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.55 | Columnx25StatOutCallAttempts | read-only | mandatory | The number of calls attempted. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.56 | Columnx25StatOutCallFailures | read-only | mandatory | The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.57 | Columnx25StatOutInterrupts | read-only | mandatory | The number of interrupt packets send by the PLE or over the PVC/VC. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.58 | Columnx25StatOutDataPackets | read-only | mandatory | The number of data packets sent by this PLE. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.59 | Columnx25StatPVCCircuits | read-only | mandatory | The number of active PVC circuits. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.60 | Columnx25StatSVCCircuits | read-only | mandatory | The number of active SVC Circuits. This includes call indications received but not yet acknowledged. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.61 | Columnx25StatRestartTimeouts | read-only | mandatory | The number of times the T20 restart timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.62 | Columnx25StatCallTimeouts | read-only | mandatory | The number of times the T21 call timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.63 | Columnx25StatResetTimeouts | read-only | mandatory | The number of times the T22 reset timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.64 | Columnx25StatClearTimeouts | read-only | mandatory | The number of times the T23 clear timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.65 | Columnx25StatDataRxmtTimeouts | read-only | mandatory | The number of times the T25 data timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.66 | Columnx25StatInterruptTimeouts | read-only | mandatory | The number of times the T26 interrupt timer expired. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.67 | Columnx25StatRetryCountExceededs | read-only | mandatory | The number of times a retry counter was exhausted. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.68 | Columnx25StatClearCountExceededs | read-only | mandatory | The number of times the R23 clear count was exceeded. |
| 1.3.6.1.4.1.1978.2.14.1.1.1.69 | Columnx25AdminTrapControl | read-write | mandatory | If enabled, it allows the system to generate x25Restart and x25VC traps |
| 1.3.6.1.4.1.1978.2.14.1.2 | Tablex25CircuitTable | not-accessible | mandatory | These objects contain general information about a specific circuit of an X.25 PLE. |
| 1.3.6.1.4.1.1978.2.14.1.2.1 | Rowx25CircuitEntry | not-accessible | mandatory | Entries of x25CircuitTable. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.1 | Columnx25CircuitIndex | read-only | mandatory | The ifIndex value for the X.25 Interface. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.2 | Columnx25CircuitChannel | read-only | mandatory | The channel number for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.3 | Columnx25CircuitStatus | read-only | mandatory | This object reports the current status of the circuit. 'Network' refers to the X.25 network below this module. 'User Application' refers to the software module… |
| 1.3.6.1.4.1.1978.2.14.1.2.1.4 | Columnx25CircuitEstablishTime | read-only | mandatory | The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs… |
| 1.3.6.1.4.1.1978.2.14.1.2.1.5 | Columnx25CircuitDirection | read-only | mandatory | The direction of the call that established this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.6 | Columnx25CircuitInOctets | read-only | mandatory | The number of octets of user data delivered to upper layer. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.7 | Columnx25CircuitInPdus | read-only | mandatory | The number of PDUs received for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.8 | Columnx25CircuitInRemotelyInitiatedResets | read-only | mandatory | The number of Resets received for this circuit with cause code of DTE initiated. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.9 | Columnx25CircuitInProviderInitiatedResets | read-only | mandatory | The number of Resets received for this circuit with cause code other than DTE initiated. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.10 | Columnx25CircuitInInterrupts | read-only | mandatory | The number of interrupt packets received for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.11 | Columnx25CircuitOutOctets | read-only | mandatory | The number of octets of user data sent for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.12 | Columnx25CircuitOutPdus | read-only | mandatory | The number of PDUs sent for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.13 | Columnx25CircuitOutInterrupts | read-only | mandatory | The number of interrupt packets sent on this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.14 | Columnx25CircuitDataRetransmissionTimeouts | read-only | mandatory | The number of times the T25 data retransmission timer expired for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.15 | Columnx25CircuitResetTimeouts | read-only | mandatory | The number of times the T22 reset timer expired for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.16 | Columnx25CircuitInterruptTimeouts | read-only | mandatory | The number of times the T26 Interrupt timer expired for this circuit. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.17 | Columnx25CircuitCallParamId | read-only | mandatory | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The ent… |
| 1.3.6.1.4.1.1978.2.14.1.2.1.18 | Columnx25CircuitCalledAddress | read-only | mandatory | The Called X.121 Address in the Incoming or Outgoing Call packets. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.19 | Columnx25CircuitCallingAddress | read-only | mandatory | The Calling X.121 Address in the Incoming or Outgoing Call packets. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.20 | Columnx25CircuitOriginallyCalledAddress | read-only | mandatory | For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it … |
| 1.3.6.1.4.1.1978.2.14.1.2.1.21 | Columnx25CircuitDescr | read-write | mandatory | A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of… |
| 1.3.6.1.4.1.1978.2.14.1.2.1.22 | Columnx25CircuitRNRReceive | read-only | mandatory | This element shows whether a receive RNR (from the network) condition exits. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.23 | Columnx25CircuitRNRSent | read-only | mandatory | This element shows whether a sent RNR (to the network) condition exits. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.24 | Columnx25CircuitTrapType | read-only | mandatory | The type of event that caused the trap to occur. reset - generated whenever that packet type is sent or received. clear - generated whenever that packet type i… |
| 1.3.6.1.4.1.1978.2.14.1.2.1.25 | Columnx25CircuitTrapCause | read-only | mandatory | The cause field of the message that caused the trap to occur. |
| 1.3.6.1.4.1.1978.2.14.1.2.1.26 | Columnx25CircuitTrapDiagnostic | read-only | mandatory | The diagnostic field of the message that caused the trap to occur. |
| 1.3.6.1.4.1.1978.2.14.1.3 | Tablex25CallParmTable | not-accessible | mandatory | These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of thes… |
| 1.3.6.1.4.1.1978.2.14.1.3.1 | Rowx25CallParmEntry | not-accessible | mandatory | Entries of x25CallParmTable. |
| 1.3.6.1.4.1.1978.2.14.1.3.1.1 | Columnx25CallParmIndex | read-write | mandatory | A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossi… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.2 | Columnx25CallParmStatus | read-write | mandatory | The status of this call parameter entry. See RFC 1271 for details of usage. |
| 1.3.6.1.4.1.1978.2.14.1.3.1.3 | Columnx25CallParmRefCount | read-write | mandatory | The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value o… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.4 | Columnx25CallParmInPacketSize | read-write | mandatory | The default receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a de… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.5 | Columnx25CallParmOutPacketSize | read-write | mandatory | The default transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.6 | Columnx25CallParmInWindowSize | read-write | mandatory | The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| 1.3.6.1.4.1.1978.2.14.1.3.1.7 | Columnx25CallParmOutWindowSize | read-write | mandatory | The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| 1.3.6.1.4.1.1978.2.14.1.3.1.8 | Columnx25CallParmAcceptReverseCharging | read-write | mandatory | An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of alwaysRefuse is … |
| 1.3.6.1.4.1.1978.2.14.1.3.1.9 | Columnx25CallParmProposeReverseCharging | read-write | mandatory | An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.10 | Columnx25CallParmFastSelect | read-write | mandatory | Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means alwaysReject.… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.11 | Columnx25CallParmInThruPutClasSize | read-write | mandatory | The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.12 | Columnx25CallParmOutThruPutClasSize | read-write | mandatory | The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tc… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.13 | Columnx25CallParmCug | read-write | mandatory | The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility request… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.14 | Columnx25CallParmCugoa | read-write | mandatory | The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three cont… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.15 | Columnx25CallParmBcug | read-write | mandatory | The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characte… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.16 | Columnx25CallParmNui | read-write | mandatory | The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero leng… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.17 | Columnx25CallParmChargingInfo | read-write | mandatory | The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use no… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.18 | Columnx25CallParmRpoa | read-write | mandatory | The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 char… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.19 | Columnx25CallParmTrnstDly | read-write | mandatory | The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (t… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.20 | Columnx25CallParmCallingExt | read-write | mandatory | The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be con… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.21 | Columnx25CallParmCalledExt | read-write | mandatory | The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be conv… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.22 | Columnx25CallParmInMinThuPutCls | read-write | mandatory | The minimum input throughput Class. A value of 17 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 16 indi… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.23 | Columnx25CallParmOutMinThuPutCls | read-write | mandatory | The minimum output throughput Class. A value of 17 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 16 ind… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.24 | Columnx25CallParmEndTrnsDly | read-write | mandatory | The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.25 | Columnx25CallParmPriority | read-write | mandatory | The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requeste… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.26 | Columnx25CallParmProtection | read-write | mandatory | A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the p… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.27 | Columnx25CallParmExptData | read-write | mandatory | The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not ha… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.28 | Columnx25CallParmUserData | read-write | mandatory | The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.29 | Columnx25CallParmCallingNetworkFacilities | read-write | mandatory | The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.30 | Columnx25CallParmCalledNetworkFacilities | read-write | mandatory | The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code.… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.31 | Columnx25CallParmInMaxPktSize | read-write | mandatory | The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a de… |
| 1.3.6.1.4.1.1978.2.14.1.3.1.32 | Columnx25CallParmOutMaxPktSize | read-write | mandatory | The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means… |
| 1.3.6.1.4.1.1978.2.14.2 | Nodex25Traps | |||
| 1.3.6.1.4.1.1978.2.14.2.1 | Nodex25L3Traps | |||
| 1.3.6.1.4.1.1978.2.14.2.1.1 | Nodex25Restart | This trap means the X.25 PLE completed a link restart packet has been sent and: a) a restart packet was received (Restart Collision) b) a restart confirm packe… | ||
| 1.3.6.1.4.1.1978.2.14.2.1.2 | Nodex25VC | Sent if a virtual circuit needs to send a trap for one of its reasons listed in x25CircuitTrapType. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| InterfaceIndex | INTEGER | ||
| X121Address | OCTET STRING (SIZE(0..20)) | ||
| X25CallParamIndex | INTEGER |