MIB Viewer
MIB Viewer Desktop New

erpsInstanceHoldoffTimer

OBJECT-TYPE
1.3.6.1.4.1.259.10.1.51.1.62.9.1.8
Access
read-create
Status
current
Sub-identifiers
0
Configures the value of the holdoff timer which is used to prevent reporting error event immediately to protection switching if the provisioned holdoff timer value is non-zero. The range is in 100 ms steps between 0 and 10 seconds, with a default value of 0 ms.
Integer32 (0..10000)