MIB Viewer
MIB Viewer Desktop New

fsDPnacPeriodicSyncTime

OBJECT-TYPE
1.3.6.1.4.1.2076.64.6.2
Access
read-write
Status
current
Sub-identifiers
0
This object configures the D-PNAC periodic sync timer. This periodic sync timer is used to configure the transmission interval of D-PNAC periodic-sync PDUs. The configured value of this timer is applicable only from the next start/re-start of the timer. In master node, this timer expiry is used to identify the slave down and remove the slave node information. This runs individually in each D-PNAC node. If this object is configured with a value of '0', then no periodic-sync messages will be sent from that D-PNAC node. The periodic sync timer has a period from 0 to 300 seconds, configurable in units of seconds.