MIB Viewer
MIB Viewer Desktop New

fsY1564SlaTestSelector

OBJECT-TYPE
1.3.6.1.4.1.29601.2.88.2.1.1.19
Access
read-write
Status
current
Sub-identifiers
0
This object specifies the Test Input to be tested for the Test. A FOUR BYTE integer is used to specify the Test Inputs. Each BIT in the four byte integer represents the tests are to be included in Service Configuration Test. The mapping between the bit positions and the test inputs are as follows: 0 - Simple CIR Validation Test 1 - Step Load CIR Test 2 - EIR Configuration Test, Colour-Aware/Non-Colour-Aware based on the value set for the object fsY1564SlaColormode or fsY1564ServiceConfColorMode. 3 - Traffic Policing Test, Colour-Aware/Non-Colour-Aware based on the value present in the object fsY1564SlaColormode or fsY1564ServiceConfColorMode. The remaining bits are unused. Combination of test inputs are also allowed. For example, if the bits 0 and 3 are set, then the service configuration test is selected with Simple CIR Valdation Test and EIR Configuration Test. The user has to enter the corresponding integer value for the bits set. For Example if the bits 0 (integer value 1) and 3 (Integer value 8) are set, the user has to enter the value 9 in decimal and equivalent Hex value is 9. By default, Simple CIR, Step Load CIR, EIR - Non-Colour-Aware and Traffic policing - Non-Color-Aware tests are selected.
Integer32 (0..255)