MIB Viewer

hw1588ClkPtpPortState

OBJECT-TYPE
1.3.6.1.4.1.2011.6.25.1.10.1.1
Access
read-only
Status
current
Sub-identifiers
0
1588 port status. Options: 1.initializing(1) - indicates that the state of 1588 clock PTP port is initializing 2.faulty(2) - indicates that the state of 1588 clock PTP port is faulty 3.disabled(3) - indicates that the state of 1588 clock PTP port is disabled 4.listening(4) - indicates that the state of 1588 clock PTP port is listening 5.premaster(5) - indicates that the state of 1588 clock PTP port is premaster 6.master(6) - indicates that the state of 1588 clock PTP port is master 7.passive(7) - indicates that the state of 1588 clock PTP port is passive 8.uncalibrated(8) - indicates that the state of 1588 clock PTP port is uncalibrated 9.slave(9) - indicates that the state of 1588 clock PTP port is slave 10.invalid(255) - indicates that the state of 1588 clock PTP port is invalid
INTEGER { initializing(1), faulty(2), disabled(3), listening(4), premaster(5), master(6), passive(7), uncalibrated(8), slave(9), invalid(255) }