hwXdslGfastConfTddProfTtrUs

OBJECT-TYPE
1.3.6.1.4.1.2011.6.115.1.5.5.1.1.6
Access
read-write
Status
current
Sub-identifiers
0
A parameter received by the FTU-O with the TXOPus primitive, indicating that the first TTRus upstream symbol positions in the logical frame are allocated to the normal operation interval (NOI). The remaining (Mus - TTRus) upstream symbol positions in the logical frame are available for allocation to the discontinuous operation interval (DOI). The range of valid TTRus values is 1 to Mus. The default value is Mus.
Unsigned32(1..25)