Sub-identifiers
0
The Downstream Up-Shift Noise Margin value, to be used when hwXdslLineConfRaModeDs is set to DynamicRa. If the downstream noise margin is above this value and stays above it for more than the time specified by the hwXdslServProfRaUsTimeDs, the xTU-R shall attempt to increase the downstream net data rate. The Downstream Up-shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). Unit: 0.1 dB
Unsigned32(0..310)