MIB Viewer

hwXdslTR129LineConfProfGfastRaDsNrmDs

OBJECT-TYPE
1.3.6.1.4.1.2011.6.115.1.5.1.5.1.93
Access
read-create
Status
current
Sub-identifiers
0
The G.fast Downstream Down-Shift Noise Margin value, to be used when hwXdslTR129LineConfProfGfastRaModeDs is set to dynamicRa. If the downstream noise margin is below this value, and stays below it for more than the time specified by the hwXdslTR129LineConfProfGfastDsTimeDs, the xTU-R shall attempt to increase the Downstream net data rate. The Downstream Down-Shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). Unit: 0.1 dB.
Gauge32 (0..310)