MIB Viewer

hwXdslTR129LineConfProfGfastRaUsNrmDs

OBJECT-TYPE
1.3.6.1.4.1.2011.6.115.1.5.1.5.1.91
Access
read-create
Status
current
Sub-identifiers
0
The G.fast Downstream Up-Shift Noise Margin value. If the downstream noise margin is above this value, and stays above it for more than the time specified by the hwXdslTR129LineConfProfGfastUsTimeDs, the xTU-R shall attempt to increase the Downstream net data rate. The Downstream Up-Shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). Unit: 0.1 dB.
Gauge32 (0..310)