MIB Viewer
MIB Viewer Desktop New

ifAmplifierEdfaWantedGainTilt

OBJECT-TYPE
1.3.6.1.4.1.8708.2.65.2.5.1.1.4
Access
read-write
Status
current
Sub-identifiers
0
The wanted EDFA gain tilt. A negative value will amplify shorter wavelengths more than longer wavelengths. Range and default value depends on type of amplifier. OARAED21/HG Min: -2 Max: 0 Default: -1 OA20C/VG/II, OA2-20C/VG/II Min: -1 Max: 0 Default: 0
Signed32WithNA ( -20..0 | 2147483647 )