rcPTP1588ClkAccuracy

OBJECT-TYPE
1.3.6.1.4.1.15004.4.12.1.26
Access
read-write
Status
current
Sub-identifiers
0
This parameter allows the user to configure the desired clock accuracy. This represents the instantaneous value of the time offset between master and slave clocks. The system will generate an alarm if the time offset from the master exceeds the desired accuracy. This mib object is supported only for OC and OC+TC clock type.
INTEGER { timeAccurateTo50ns(0), timeAccurateTo100ns(1), timeAccurateTo250ns(2), timeAccurateTo1us(3), timeAccurateTo2to5us(4), timeAccurateTo10us(5), timeAccurateTo25us(6), timeAccurateTo100us(7), timeAccurateTo250us(8), timeAccurateTo1ms(9), timeAccurateTo2to5ms(10), timeAccurateTo10ms(11), timeAccurateTo25ms(12), timeAccurateTo100ms(13), timeAccurateTo250ms(14) }