OBJECT-TYPE
1.3.6.1.4.1.42229.1.2.19.14.1.1.2
Access
read-only
Status
current
Sub-identifiers
0
Time in milliseconds between the device's sample of a telemetry data source. For example, setting this to 2000 would require the local device to collect the telemetry data every 2000 milliseconds. There can be latency or jitter in transmitting the data, but the sample must occur at the specified interval. The timestamp must reflect the actual time when the data was sampled, not simply the previous sample timestamp + sample-interval. If sample-interval is set to 0, the telemetry sensor becomes event based. The sensor must then emit data upon every change of the underlying data source. UNITS:millisecond default value :10000