MIB Viewer

snMspsVrrpOperTrackRowStatus

OBJECT-TYPE
1.3.6.1.4.1.4329.20.1.1.1.1.43.1.4.1.3
Access
read-create
Status
current
Sub-identifiers
0
The RowStatus variable should be used in accordance to installation and removal conventions for conceptual rows. To create a row in this table, a manager sets this object to either createAndGo(4) or createAndWait(5). Until instances of all corresponding columns are appropriately configured and atleast one entry in snMspsVrrpOperTrackGroupIfTable is created, the value of the corresponding instance of the 'snMspsVrrpOperTrackRowStatus' column will be read as notReady(3). In particular, a newly created row cannot be made active(1) until (minimally) one or more entries are created in snMspsVrrpOperTrackGroupIfTable is created, value of the object snMspsVrrpOperTrackedGroupTrackedLinks is set to number of entries created in snMspsVrrpOperTrackGroupIfTable or 0. A typical order of operation to add a row is: 1. Create a row in snMspsVrrpOperTrackGroupTable with createAndWait(5). 2. Create one or more entries in snMspsVrrpOperTrackGroupIfTable 3. Set snMspsVrrpOperTrackedGroupTrackedLinks as the number of entries created in snMspsVrrpOperTrackGroupIfTable. 4. Set snMspsVrrpOperTrackRowStatus to active(1). An Entry in this table can be deleted, only if there are no entries in snMspsVrrpOperTrackGroupIfTable. Before an entry is deleted in snMspsVrrpOperTrackGroupIfTable is deleted, the value snMspsVrrpOperTrackedGroupTrackedLinks should be adjusted. Otherwise, error will be thrown. Value 'snMspsVrrpOperTrackGroupIndex' is used as a reference in snMspsVrrpOperTable. Acceptable configurable values for this object are createAndGo(4), createAndWait(5), active(1) and destroy(6).
RowStatus