OBJECT-TYPE
1.3.111.2.802.1.1.20.1.1.6
Access
read-write
Status
current
Sub-identifiers
0
Most-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The value of priority1 shall be 255 for a time-aware system that is not grandmaster-capable. The value of priority1 shall be less than 255 for a time-aware system that is grandmaster-capable. The value 0 shall be reserved for future management use, i.e., the valueof priority1 shall be set to 0 only via management action, and shall not be specified as a default value by a user of this standard. In the absence of a default value set by a user of this standard, the default value shall be set as below: a) system type of network infrastructure time-aware system to value 246; b) portable time-aware system, 250; c) other time-aware systems, 248.
Unsigned32(0..255)