MIB Viewer

pktcSigPulseSignalFrequency

OBJECT-TYPE
1.3.6.1.2.1.169.1.1.20.1.2
Access
read-write
Status
current
Sub-identifiers
0
This object is only applicable to the initialRing, enableMeterPulse, and meterPulseBurst signal types. This object identifies the frequency of the generated signal. The following table defines the default values for this object depending on signal type: pktcSigPulseSignalType Default initialRing 25 enableMeterPulse 16000 meterPulseBurst 16000 The value of twentyfive MUST only be used for the initialRing signal type. The values of twelvethousand and sixteenthousand MUST only be used for enableMeterPulse and meterPulseBurst signal types. An attempt to set this object while the value of pktcSigPulseSignalType is not initialRing, enableMeterPulse, or meterPulseBurst will result in an 'inconsistentValue' error.
INTEGER { twentyfive(1), twelvethousand(2), sixteenthousand(3) }