MIB Viewer

rptrReset

OBJECT-TYPE
1.3.6.1.3.29.1.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
Setting this object to reset(2) causes a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std]. Setting this object to noReset(1) has no effect. The agent will always return the value noReset(1) when this object is read. This action does not reset the management counters defined in this document nor does it affect the portAdminStatus parameters. Included in this action is the execution of a disruptive Self-Test with the following characteristics: a) The nature of the tests is not specified. b) The test resets the repeater but without affecting management information about the repeater. c) The test does not inject packets onto any segment. d) Packets received during the test may or may not be transferred. e) The test does not interfere with management functions. As a result of this action a rptrResetEvent trap should be sent.
INTEGER { noReset(1), reset(2) }