MIB Viewer

anxRipForceNewrt

OBJECT-TYPE
1.3.6.1.4.1.15.2.5.108
Access
read-write
Status
mandatory
Sub-identifiers
0
When enabled, this parameter specifies the timeout value in seconds that the Annex waits for a router to send periodic RIP updates. If the Annex does not hear from the primary router within this timeout period and a secondary router broadcasts a valid replacement route, the replacement route takes precedence regardless of the metric. The default and recommended value is 0 or \'off\' which disables this feature. The maximum value is 255 seconds. This MIB object corresponds to the NA/admin Annex parameter 'rip_force_newrt'.
INTEGER (0..255)