MIB Viewer

salixSysSyncForcedState

OBJECT-TYPE
1.3.6.1.4.1.2158.2.3.1.5.14
Access
read-only
Status
current
Sub-identifiers
0
This variable indicates the state of the sync module with regard to switching between the configured active reference, the value of the 'salixSysSyncConfiguredActiveRef' variable, and the alternate active reference. The alternate active reference is identified by the 'salixSysSyncPrimaryRef' or 'salixSysSyncSecondaryRef' that is not configured as the 'salixSysSyncConfiguredActiveRef'. none(0) - the sync module is in a state where it is free to switch between the configured active reference the alternate active reference. revertiveSwitchInhibit - the state of the sync module after switching from the 'salixSysSyncConfiguredActiveRef' to the 'salixSysSyncCurrentActiveRef' when the 'salixSysSyncRevertiveSwitch' is configured as 'false'. In this state the sync module will not revert back to using the 'salixSysSyncConfiguredActiveRef' unless the 'salixSysSyncCurrentActiveRef' has failed and the state of the active reference defined by the 'salixSysSyncConfiguredActiveRef' variable is 'valid'. autoReferenceSwitchInhibit - the state of the sync module when the 'salixSysSyncAutoReferenceSwitch' variable is configured as 'false'. In this state the sync module will not switch to using the alternate active reference unless the 'salixSysSyncCurrentActiveRef' has failed and the state of the alternate active reference is 'valid'.
INTEGER { none(0), revertiveSwitchInhibit(1), autoReferenceSwitchInhbit(2) }