MIB Viewer

obmCalloutTriggerEvent

OBJECT-TYPE
1.3.6.1.4.1.285.6.11
Access
read-write
Status
mandatory
Sub-identifiers
0
This object controls which events will trigger the callout sub-system to try to establish a connection using the obmCalloutPhoneNumber. The value is a bitmask, representing the following possibilities: 0x01 : Fatal Error. (CAU/CAM/BRIDGE) 0x02 : Adapter Failure. (CAU) 0x02 : Start-up Failure. (BRIDGE) 0x04 : Fan Failure. (SWI) 0x04 : LAM Failure. (CAU/CAM) 0x08 : Main ring Wrap due to beacon. (CAU) 0x10 : HLM Connection Lost. (CAU/CAM) 0x10 : Temperature warning (SWI) 0x20 : Power System Failure (CAU) 0x40 : WAN link failure (BRIDGE) 0x40 : Port auto disabled (SWI)
OCTET STRING