MIB Viewer

dh90SlotPassword

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.10.1.5.1.10
Access
read-write
Status
mandatory
Sub-identifiers
0
Password used to enable privileged operations on devices which support the MOP and RBMS protocols for remote management. Setting a value containing embedded spaces or tabs will result in a 'badValue' response. Supported devices include: DECserver 90L, DECserver 90L+, DECbridge 90 and DECbridge 90FL. For DECserver 90's, the maximum password length is eight (8). For DECbridge 90's, the maximum password length is sixteen (16). Passwords which exceed these values will result in a 'badValue' response. Reads to this variable for supported devices will always return a null string. For other devices, access to this variable will result in a 'noSuchName' response. NOTE: It is imperative that the DECagent 90 be password-synchronized with the remote devices it is managing. If a device has a password, the DECagent 90 will not be able to perform sets to it without the correct password. Sets to this variable cause the value to be stored in the DECagent 90's non-volatile storage for use when accessing the device in the specified slot.
DisplayString (SIZE (0..16))