MIB Viewer

zxGponOnuSurvivalTime

OBJECT-TYPE
1.3.6.1.4.1.3902.1012.3.50.11.2.1.18
Access
read-only
Status
current
Sub-identifiers
0
This attribute indicates the minimum guaranteed time in milliseconds between the loss of external power and the silence of the ONU. This does not include survival time attributable to a backup battery. The value zero implies that the actual time is not known. (R) (optional) (1 byte)