zxGponONTPowerSheddingDataSheddingInterval

OBJECT-TYPE
1.3.6.1.4.1.3902.1012.3.50.11.8.1.2
Access
read-write
Status
current
Sub-identifiers
0
For each class of service, an interval attribute is defined below. The value 0 disables power shedding, while the value 1 enables immediate power shed, that is, as soon as AC power fails. Other values specify the time, in seconds, to keep the service active after AC failure before shutting them down and shedding power. Upon ME instantiation, the ONT sets each of the interval attributes to 0.(2 bytes)
INTEGER