MIB Viewer

zxAnXdsl2LConfInpMinShineUs

OBJECT-TYPE
1.3.6.1.4.1.3902.1015.1001.1.3.20.1.32
Access
read-create
Status
current
Sub-identifiers
0
GINP configuration parameters of upstream. The INPMIN_SHINE_RTX is a configuration parameter that, for the case of subcarrier spacing of 4.3125kHz, is used to derive the control parameter INP_min which specifies the minimum impulse noise protection against SHINE. It is used in the Channel Initialization Policy and on-line reconfiguration procedures. The downstream and upstream values of INPMIN_SHINE_RTX shall be configured in the CO MIB. The value range from 0 to 63 DMT symbols of 4.3125 kHz in steps of 1 DMT. The control parameter INP_min shall be set to the same value as the configuration parameter INPMIN_SHINE_RTX.
Integer32(0..63)