MIB Viewer

zxAnXdsl2SeltTestStatus

OBJECT-TYPE
1.3.6.1.4.1.3902.1015.1001.1.7.2.1.10
Access
read-only
Status
current
Sub-identifiers
0
Possible failure reasons associated with performing Single Ended Loop Test (SELT) on a DSL line. Possible values are: none (1) - The default value in case LDSF was never requested for the associated line. success (2) - The recent command completed successfully. inProgress (3) - The Loop Diagnostics process is in progress. unsupported (4) - The NE or the line card doesn't support LDSF. cannotRun (5) - The NE cannot initiate the command, due to a non specific reason. aborted (6) - The Loop Diagnostics process aborted. failed (7) - The Loop Diagnostics process failed. illegalMode (8) - The NE cannot initiate the command, due to the specific mode of the relevant line. noResources (9) - The NE cannot initiate the command, due to lack of internal memory resources. online (10)- The CPE is online but not in showtime status. parallelOverLimit (11)- The number of parallel tests has reached the upper limit. showtime (12)- The CPE is in showtime status.
INTEGER { none(1), success(2), inProgress(3), unsupported(4), cannotRun(5), aborted(6), failed(7), illegalMode(8), noResources(9), online(10), parallelOverLimit(11), showtime(12) }