MIB Viewer

zxAnEthOamErrSymPeriodThresholdLo

OBJECT-TYPE
1.3.6.1.4.1.3902.1015.61.5.1.4
Access
read-write
Status
current
Sub-identifiers
0
The two objects OamErrSymPeriodThresholdHi and OamErrSymPeriodThresholdLo together form an unsigned 64-bit integer representing the number of symbol errors that must occur within a given window to cause this event. This is defined as OamErrSymPeriodThreshold = ((2^32) * OamErrSymPeriodThresholdHi) + OamErrSymPeriodThresholdLo If OamErrSymPeriodThreshold symbol errors occur within a window of OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating the threshold has been crossed in this window. The default value for OamErrSymPeriodThreshold is one symbol error. If the threshold value is zero, then an Event Notification OAMPDU is sent periodically (at the end of every window). This can be used as an asynchronous notification to the peer OAM entity of the statistics related to this threshold crossing alarm.
Unsigned32