MIB Viewer

chanStatDataForwarding

OBJECT-TYPE
1.3.6.1.4.1.397.4.2.1.54
Access
read-only
Status
mandatory
Sub-identifiers
0
Data Forwarding. This parameter controls which character or characters cause the accumulated data to be forwarded. The possible values may be added together to forward on one of a number of conditions. The allowable values are: 0 Forward only on buffer full. 128 Forward on graphics characters. 64 Forward on all characters in columns 0 and 1 of the International Alphabet No. 5. 1 Forward on A-Z, a-z and 0-9. 2 Forward on Carriage Return. 4 Forward on ESC, BEL, ENQ, ACK. 8 Forward on DEL, CAN, DC2. 16 Forward on EXT, EOT. 32 Forward on HT, LF, VT, FF.
INTEGER