MIB Viewer

chanParamEditServiceSignals

OBJECT-TYPE
1.3.6.1.4.1.397.4.3.1.31
Access
read-write
Status
mandatory
Sub-identifiers
0
Edit Service Signals. This parameter enables the user to edit the PAD service signals (echoing). The valid settings are: 0 No editing PAD service signals are echoed. 1 A '\' will be echoed for each character deleted. 2 A 'BS' character will be echoed for each character deleted. 8 and 32-126 Specifies the decimal value of the ASCII character to be echoed for each character deleted.
INTEGER (0..126)