MIB Viewer

lsAction

OBJECT-TYPE
1.3.6.1.4.1.43.17.11
Access
read-write
Status
mandatory
Sub-identifiers
0
Value when read will be other. Writing a value to this object will result in the associated action taking place. Note that it is possible to disconnect the management station from the LinkSwitch by issuing the disconnect-FDDI or disconnect-Eth actions, depending of course where the management station is connected to the LinkSwitch. For those actions which are tests, the result is in lsTestResult. If the action is disconnect-FDDI, the FDDI ring will function internally for inter-segment frames.
INTEGER { other(1), age-addr-table(2), clear-addr-table(3), disconnect-FDDI(4), connect-FDDI(5), disconnect-Eth(6), connect-Eth(7), test-fddipath(8), test-ethports(9), test-lsfunc(10), test-addr-filter(11) }