cdx6500SSDeactivationMode

OBJECT-TYPE
1.3.6.1.4.1.449.2.1.2.2.14.1.7
Access
read-only
Status
mandatory
Sub-identifiers
0
This specifies how the switched service/backup port is deactivated after the original link is up. none - Backup port can only be deactivated by operator intervention. busyOut - The backup port is deactivated after all the calls on that port are cleared for a predetermined amount of time. This substitutes the value assigned to the parameter Link Hold Time with the value assigned to the parameter Idle Disconnect Time in the X.25 Port Record. The Idle Disconnect Time will then work as described in the Operators Guide. When Deactivation Mode = BUSY OUT and Link Hold Time = 0 (zero) the overall effect is the same as setting this entry to NONE. imm - The backup link is terminated IMMediately when the monitored port is restored regardless of how many calls are present. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility.
INTEGER { none (0), busyOut (1), imm (2), newvalNone (50) }