MIB Viewer

docsPnmCmtsUtscCfgMinislotCount

OBJECT-TYPE
1.3.6.1.4.1.4491.2.1.27.1.3.10.2.1.4
Access
read-write
Status
current
Sub-identifiers
0
This attribute specifies the minislot number at the beginning of which the CCAP starts the upstream spectrum sample capture. This attribute is applicable only when the TriggerMode attribute is set to MiniSlotCount and is ignored if TriggerMode is set to any other value.
Unsigned32