MIB Viewer

pktcEnEndPntRunFgnPotTsts

OBJECT-TYPE
1.3.6.1.4.1.4491.2.2.6.2.1.2.2.1.4
Access
read-write
Status
current
Sub-identifiers
0
This MIB object is used to initiate one or more test cases associated with a supported foreign potential detection. Thus, whenever one or more BITS corresponding to supported foreign scenario potential detection mechanisms are set to a value of '1', the MTA MUST enable those tests. Once the tests are executed, the MTA MUST: - set the corresponding bit to a value of '0' - update the corresponding BITS in the MIB Objects 'pktcEnEndPntFgnTestValidity' and 'pktcEnEndPntFgnTestResults'. If an SNMP SET attempts to set a bit corresponding to an unsupported condition to a value of '1', then the MTA MUST reject the entire SNMP SET and report an 'inconsistent value' error. Whenever a test is being run on an EndPoint the MTA MUST set the corresponding 'ifOperStatus' MIB Object to a value of 'testing(3)' for the whole duration of the test. When the test is completed, the MTA MUST set the ifOperStatus to the value corresponding to the current state of the line. Note: Whenever multiple tests are run, the ordering of the tests or the results is vendor dependent and need not necessarily follow the ordering of BITS in this MIB Object.
BITS { runFgnPotentialTsts (0), runHazardousPotTsts (1) }