MIB Viewer

plxCommunityAccess

OBJECT-TYPE
1.3.6.1.4.1.465.11.1.1.3
Access
read-write
Status
mandatory
Sub-identifiers
0
The access level for the community name. This variable must be set to a value of readOnly(1), readWrite(2), or superUser(3) for the corresponding plxCommunityName variable in the table to be valid. A value of readOnly(1) allows 'GET' only privleges on all MIB objects except the community table. A value of readWrite(2) allows 'GET' and 'SET' privleges on all MIB objects except the community table. A value of superUser(3) allows 'GET' and 'SET' privleges on all MIB objects including the community table. The value invalid(100) is returned for invalid table entries. A 'SET' with this value clears the entry from the table.
INTEGER { readOnly(1), readWrite(2), superUser(3), invalid(100) }