MIB Viewer

lineQualityFrameCount

OBJECT-TYPE
1.3.6.1.4.1.485.3.5.2.1.1.4
Access
read-only
Status
mandatory
Sub-identifiers
0
This entry contains the number of frames received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. When this value reaches 255, it then rolls back to 0. Applicable to SDLC only.
Counter