MIB Viewer

x25Billing

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.6.29.5
Access
read-write
Status
mandatory
Source
CXX25-MIB
Sub-identifiers
0
Determines if this layer generates the x25BillingIndication trap. For switched virtual circuits the trap is generated each time a call is cleared. For permanent virtual circuits the trap is generated each time the x25SapPvcBillingTimer expires. Options: disabled (1): This layer does not generate the x25BillingIndication trap. enabled (2): This layer generates the x25BillingIndication trap. Default Value: disabled (1) Related Objects: x25BillingSegmentSize x25SapPvcBillingTimer x25SapSbscrChargingInformation x25SapSbscrNetworkUserId x25PvcBilling x25PvcSrcAddress x25PvcDstAddress x25BillingIndication Configuration Changed: administrative and operative
INTEGER { disabled (1), enabled (2) }