MIB Viewer

csuPreEqualizer

OBJECT-TYPE
1.3.6.1.4.1.498.2.1.1.10
Access
read-write
Status
mandatory
Sub-identifiers
0
This variable is used to set the Cascade PreEqualization option for matching the cascade port line length, providing transmitter pre-equalization for lengths of 130 ft (0-130 feet), 260 ft (130-260 feet) 390 ft (260-390 feet), 530 ft (390-530 feet) or 655 ft (530-655 feet). Selecting the proper length ensures that the signal reaching the customer cascade equipment is satisfactory. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 None 552a PreEqualization Same as defined in managed object 552a V1.1 PreEqualization Same as defined in managed object 551 PreEqualization Same as defined in managed object
INTEGER { csuNoEqual(1), csu130ft(2), csu260ft(3), csu390ft(4), csu530ft(5), csu655ft(6) }