MIB Viewer

csuInitialize

OBJECT-TYPE
1.3.6.1.4.1.498.2.1.1.11
Access
write-only
Status
mandatory
Sub-identifiers
0
This variable is used to initialize specific items on the csu, csuAlarmHistory refers to initializing the Alarm History Report and a new start time is recorded. csu24HourCounter refers to initializing the 24 Hour statistics counters. All of the counters associated with the statistics will be initialized to zero. csuFactoryDefaults refers to initializing all soft-configurable options to the factory default settings. Option 'F' from the maintenance screen. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 Initialize Alarm History, Initialize Local 24 Hour Counters 552a Initialize Alarm History, Initialize Local 24 Hour Counters 552a V1.1 Initialize Alarm History, Initialize Local 24 Hour Counters 551 Initialize Alarm History, Initialize One Hour
INTEGER { csuAlarmHistory(1), csu24HourCounter(2), csuFactoryDefaults(3) }