MIB Viewer

csuInbandLoop

OBJECT-TYPE
1.3.6.1.4.1.498.2.1.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
This variable is used to set the In-Band DS1 Loopback Code Detection. inhibit refers to when the in-band loopback codes are ignored. enable refers to when the in-band loopback codes are detected and reacted to. When enabled, the Loopback Configuration must also be set. When a loopback activation or deactivation code is detected, the DSU starts or stops the type of loopback test selected with the Loopback Configuration. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 Inband Loop Same as defined in managed object 552a Inband Loop Same as defined in managed object 552a V1.1 Inband Loop Same as defined in managed object 551 Inband Loop Same as defined in managed object
INTEGER { inhibit(1), enable(2) }