iso/org/dod/internet/private/enterprises/datum/austron/products/ssu2000/.3/.5/setAlmThGpsInpTable/setMgEntry
setMgEntry
OBJECT-TYPE
1.3.6.1.4.1.601.3.1.1.3.5.2.1
Description
Input alarm attributes and settings. setMgChassis Identifies which chassis is being addressed. setMgSlot Identifies which slot position is being addressed. setMgMtieStd Set the input port setting of the MTIE limits to predefined values. setMgMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMgMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMgMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMgMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMgMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMgMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMgMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMgMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMgMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMgMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMgMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMgMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMgMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMgMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMgMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMgMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMgMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMgMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMgMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMgMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMgFreqAErrLmt Set the input port frequency error threshold for clock A. setMgFreqAClrLmt Set the input port frequency clear threshold for clock A. setMgFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMgFreqBErrLmt Set the input port frequency error threshold for clock B. setMgFreqBClrLmt Set the input port frequency clear threshold for clock B. setMgFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
Syntax
SetMgEntry
Children (29)
.1setMgChassis.2setMgSlot.3setMgMtieStd.4setMgMtie10EL1.5setMgMtie10EL2.6setMgMtie10CL1.7setMgMtie10CL2.8setMgMtie100EL1.9setMgMtie100EL2.10setMgMtie100CL1.11setMgMtie100CL2.12setMgMtie1000EL1.13setMgMtie1000EL2.14setMgMtie1000CL1.15setMgMtie1000CL2.16setMgMtie10000EL1.17setMgMtie10000EL2.18setMgMtie10000CL1.19setMgMtie10000CL2.20setMgMtie100000EL1.21setMgMtie100000EL2.22setMgMtie100000CL1.23setMgMtie100000CL2.24setMgFreqAErrLmt.25setMgFreqAClrLmt.26setMgFreqATau.27setMgFreqBErrLmt.28setMgFreqBClrLmt.29setMgFreqBTau