MIB Viewer

oHSCfgCtsIndication

OBJECT-TYPE
1.3.6.1.4.1.644.2.4.2.5.1.1.1.14
Access
read-write
Status
current
Sub-identifiers
0
A Control Signal configuration used on this port. When the Port type is X.21, this field represents the X.21 Control Signals. In all other cases, this is the Clear to Send method. forced-off (0) method is off forced-on (1) method is on track-RTS (2) asserts Request to Send (RTS) each time data needs to be transmitted and drops RTS at some point after data transmission begins.
INTEGER { forced-off(0), forced-on(1), track-RTS(2) }