MIB Viewer

crmfe100FxTxBwa

OBJECT-TYPE
1.3.6.1.4.1.868.2.4.1.2.2.24.1.40
Access
read-write
Status
mandatory
Source
MCC16-MIB
Sub-identifiers
0
This variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the nearest 64KBps. A value of zero disables data transfer, and the maximum value is 12224KBps. Data traffic is measured from the beginning of each second. Once the traffic reaches the cap specified, all traffic is discarded until the start of the next second, when the counters are reset and traffic begins to flow again. crmfe100FxTxBwa(39) limits the data flowing from the fiber interface to the twisted pair interface.
INTEGER