This module is used to configure and query IF board related parameters required in radio link configuration and preventive maintenance, including the IF board modulation mode, bandwidth, AM management, and link identifier.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.4.40.3IdentityoptixRtnIFBoardAttrThis module is used to configure and query IF board related parameters required in radio link configuration and preventive maintenance, including the IF board …
1.3.6.1.2.1.10.4.40.3.1.1.1ScalaroptixRtnIFPortBandWidthOldread-writedeprecatedIndicates the channel spacing. This parameter varies with the equipment version. Values: 10: 250M; 11: 500M; 12:750M; 16: 62P5M; 17:125M
1.3.6.1.2.1.10.4.40.3.2TableoptixRtnIFPortSNRMsethTablenot-accessibledeprecatedDescribes AM parameters of an IF board, including the AM status.
1.3.6.1.2.1.10.4.40.3.2.1RowoptixRtnIFPortSNRMsethEntrynot-accessibledeprecatedIndicates the management entry for the AM parameters of an IF port.
1.3.6.1.2.1.10.4.40.3.2.1.1ColumnoptixRtnIFPortIFBandWidthread-onlydeprecatedIndicates the channel spacing. This parameter varies with the equipment version. Values: 10: 250M; 11: 500M; 12:750M; 16: 62P5M; 17:125M
1.3.6.1.2.1.10.4.40.3.2.1.2ColumnoptixRtnIFPortBottomModread-onlydeprecatedIndicates the lowest-order modulation scheme that the AM function supports. Values:1: QPSK 2: 16QAM 3: 32QAM 4: 64QAM 5: 128QAM 6: 256QAM 10: 16QAMSTRONG 14:QP…
1.3.6.1.2.1.10.4.40.3.2.1.3ColumnoptixRtnIFPortGuaranteeMseValueread-onlydeprecatedIndicates the MSE thresholds in the guaranteed capacity modulation mode. Unit: 0.1 db
1.3.6.1.2.1.10.4.40.3.2.1.4ColumnoptixRtnIFPortPeakModread-onlydeprecatedIndicates the highest-order modulation scheme that the AM function supports. Values: 1: QPSK 2: 16QAM 3: 32QAM 4: 64QAM 5: 128QAM 6: 256QAM 10: 16QAMSTRONG 14:…
1.3.6.1.2.1.10.4.40.3.2.1.5ColumnoptixRtnIFPortPeakMseValueread-onlydeprecatedIndicates the MSE thresholds in the full capability modulation mode. Unit: 0.1 db
1.3.6.1.2.1.10.4.40.3.10.3TableoptixRtnIFPortXPICFeatureTablenot-accessibledeprecatedInclude some command about XPIC, such as:set/get XPIC state, set/get XPIC bdPolar, set/get XPIC linkId and Synchronization information to adjoin link.
1.3.6.1.2.1.10.4.40.3.10.3.1RowoptixRtnIFPortXPICFeatureEntrynot-accessibledeprecatedDescribe some command about XPIC
1.3.6.1.2.1.10.4.40.3.10.3.1.1ColumnoptixRtnIFPortXPICEnableread-writedeprecatedDespribes the state of XPIC and set the XPIC state
1.3.6.1.2.1.10.4.40.3.10.3.1.2ColumnoptixRtnIFPortXPICBdPolarread-writedeprecatedDescribe the bdpolar of XPIC and set the bdpolar of XPIC
1.3.6.1.2.1.10.4.40.3.10.3.1.3ColumnoptixRtnIFPortXPICAjoinLinkIdread-writedeprecatedDescribes the XPIC adjoin link Id and set the XPIC adjoin link Id
1.3.6.1.2.1.10.4.40.3.10.3.1.4ColumnoptixRtnIFPortXPICSyncAjoinInforead-writedeprecatedsynchronism the local NE information to adjoin NE
1.3.6.1.2.1.10.4.40.3.10.20.1.5ScalaroptixRtnIFPortXPICEnableStatusread-writedeprecatedIndicates whether an IF port is enabled with XPIC. Only the XPIC IF board supports this parameter. Values: 0: disabled 1: enabled
1.3.6.1.2.1.10.4.40.3.10.40.1.1ScalaroptixRtnIFPortBandWidthOld2read-writedeprecatedIndicates the channel spacing. This parameter varies with the equipment version. Values: 1: 3.5M 2: 7.0M 3: 14M 4: 28M 5: 40M 6: 56M 7: FCC30M 8: FCC40M 9: FCC…
1.3.6.1.2.1.10.4.40.3.10.50.1.12ScalaroptixRtnIFPortGuaranteeMseread-onlydeprecatedIndicates the MSE thresholds in the guaranteed capacity modulation mode. Unit: 0.1 db
1.3.6.1.2.1.10.4.40.3.10.50.1.13ScalaroptixRtnIFPortPeakMseread-onlydeprecatedIndicates the MSE thresholds in the full capability modulation mode. Unit: 0.1 db
1.3.6.1.2.1.10.4.40.3.10.50.1.16ScalaroptixRtnIFPortChannelBandWidthread-onlydeprecatedIndicates the BandWidth of the Channel.
1.3.6.1.2.1.10.4.40.3.10.50.1.17ScalaroptixRtnIFPortBottomModOldread-onlydeprecatedIndicates the bottom modulation mode.
1.3.6.1.2.1.10.4.40.3.10.50.1.18ScalaroptixRtnIFPortPeakModOldread-onlydeprecatedIndicates the peak modulation mode.
1.3.6.1.2.1.10.4.40.3.10.60TableoptixRtnIFPortAllModeCapacityTablenot-accessibledeprecatedDescribes the service capacity supported by an IF board in each mode.
1.3.6.1.2.1.10.4.40.3.10.60.1RowoptixRtnIFPortAllModeCapacityEntrynot-accessibledeprecatedIndicates the query entry for service capacities of an IF port in each mode.
1.3.6.1.2.1.10.4.40.3.10.60.1.1ColumnoptixRtnIFPortAMBandWidthnot-accessibledeprecatedIndicates the channel spacing.
1.3.6.1.2.1.10.4.40.3.10.60.1.2ColumnoptixRtnIFPortAMModenot-accessibledeprecatedIndicates the port modulation mode.
1.3.6.1.2.1.10.4.40.3.10.60.1.3ColumnoptixRtnIFPortAMCapacityread-onlydeprecatedIndicates the service capacity in a mode. Unit: M
1.3.6.1.2.1.10.4.40.3.10.60.1.4ColumnoptixRtnIFPortAMMaxE1Numread-onlydeprecatedIndicates the maximum number of E1s supported by a mode.
1.3.6.1.2.1.10.4.40.3.10.60.1.5ColumnoptixRtnIFPortAMCapacityOldread-onlydeprecatedIndicates the service capacity in a mode. Unit: M
1.3.6.1.2.1.10.4.40.3.10.70TableoptixRtnIFPortAllModeXpicCapacityTablenot-accessibledeprecatedDescribes the service capacity supported by an IF board in each mode when the XPIC function is enabled.
1.3.6.1.2.1.10.4.40.3.10.70.1RowoptixRtnIFPortAllModeXpicCapacityEntrynot-accessibledeprecatedIndicates the query entry for service capacities of an IF port in each mode when the XPIC function is enabled.
1.3.6.1.2.1.10.4.40.3.10.70.1.1ColumnoptixRtnIFPortAmCapacityForXpicread-onlydeprecatedIndicates the service capacity supported by a mode when the XPIC function is enabled. Unit: M
1.3.6.1.2.1.10.4.40.3.10.70.1.2ColumnoptixRtnIFPortAmMaxE1NumForXpicread-onlydeprecatedIndicates the maximum number of E1s supported by a mode when the XPIC function is enabled.
1.3.6.1.2.1.10.4.40.3.11.1TableoptixRtnFMTestODUPowerTablenot-accessibledeprecatedIndicates setting the transmit power table of an ODU in the fade margin test.
1.3.6.1.2.1.10.4.40.3.11.1.1RowoptixRtnFMTestODUPowerEntrynot-accessibledeprecatedIndicates setting the transmit power entry of an ODU in the fade margin test.
1.3.6.1.2.1.10.4.40.3.11.1.1.1ColumnoptixRtnFadeMarginTxPowerread-writedeprecatedIndicates the ODU transmit power. The value ranges from -100 to +350 in the unit of 0.1 dBm.
1.3.6.1.2.1.10.4.40.3.11.1.1.2ColumnoptixRtnFadeMarginOduWorkread-writedeprecatedIndicates setting the working status of the ODU in the fade margin test.
1.3.6.1.2.1.10.4.40.3.12.2.1.4ScalaroptixRtnIFPrbsTypeIndexnot-accessibledeprecatedIndicates the PRBS test type: 1-E1 2-IF 3-CPRI/OBSAI
1.3.6.1.2.1.10.4.40.3.12.2.1.5ScalaroptixRtnIFPrbsPathIdIndexnot-accessibledeprecatedIndicates the ID of a path used in the PRBS test. Set the parameter to 0 if this field is not in use (applicable to RTN 310/320/360/380/380H working in Etherne…
1.3.6.1.2.1.10.4.40.3.12.2.1.6ScalaroptixRtnIFPrbsDirectionIndexnot-accessibledeprecatedIndicates the PRBS test direction. 1-Ingress 2-Egress