MIB Viewer
MIB Viewer Desktop New

cmGwWanSetToFactory

OBJECT-TYPE
1.3.6.1.4.1.1166.1.19.52.1.1.2
Access
read-write
Status
current
Sub-identifiers
0
Setting this object to true(1) causes the WAN default options to be returned back to factory defaults. Reading this object always returns false(2). The following object values are reset when cmGwWanSetToFactory is set to 'true'. cmGwWanDhcpcAdminStatus is set to it's default value. The values of the remaining objects are all cleared. Strings are set to NULL and IP addresses are set to 0.0.0.0. cmGwWanDhcpcAdminStatus, cmGwWanInetAddressType, cmGwWanInetAddress, cmGwWanHostName, cmGwWanSubnetMaskType, cmGwWanSubnetMask, cmGwWanRouterType, cmGwWanRouter All entries in cmGwWanDnsServerTable will be destroyed. All reset defaults will not take effect until the unit is rebooted.
TruthValue