MIB Viewer
MIB Viewer Desktop New

mplsOamBfdSessRemoteDiag

OBJECT-TYPE
1.3.6.1.4.1.8708.2.44.2.2.1.1.8
Access
read-only
Status
current
Sub-identifiers
0
A diagnostic code specifying the remote systems reason for the last transition of the session from up to some other state. noDiagnostic - Normal state of session when no fault detected. controlDetectionTimeExpired - No continuity check messages received. Connection to remote BFD session broken. echoFunctionFailed - Not used neighborSignaledSessionDown - Remote BFD session is in state down forwardingPlaneReset - not used pathDown - not used concatenatedPathDown - not used administrativelyDown - BFD session is in administrative down state reverseConcatenatedPathDown - Not used misconnectionDefect - BFD session has detected a misconnectivity defect. MPLS-TP MEP IDs does not match between local and remote session.
BfdDiagTC