Optical RX/TX Power Catalog
Last updated September 15, 2026
Optical RX/TX power is the signal strength an SFP, XFP, or QSFP transceiver is receiving or transmitting, measured in dBm.
Most transceivers expose this through the SFF-8472 Digital Diagnostics Monitoring standard at the hardware level, but there's no single standardized MIB for collecting this information, so each vendor must define their own.
Search the catalog to filter optical power oids by vendor/model.
| Vendor | Model / Platform | MIB | Object | OID | Description |
|---|---|---|---|---|---|
| 3Com | A3COM-HUAWEI-TRANSCEIVER-INFO | A3COM-HUAWEI-TRANSCEIVER-INFO-MIB | h3cTransceiverCurRXPower | 1.3.6.1.4.1.43.45.1.10.2.70.1.1.1.12 | Indicating the current received power . The unit is in hundredths of dBM. |
| 3Com | A3COM-HUAWEI-TRANSCEIVER-INFO | A3COM-HUAWEI-TRANSCEIVER-INFO-MIB | h3cTransceiverCurTXPower | 1.3.6.1.4.1.43.45.1.10.2.70.1.1.1.9 | Indicating the current transmitted power . The unit is in hundredths of dBM. |
| ADTRAN | ADTRAN-GEN-OPTICAL-AMPLIFIER | ADTRAN-GEN-OPTICAL-AMPLIFIER-MIB | adGenOpticalAmplifierLaserPumpReflectedPower | 1.3.6.1.4.1.664.5.70.41.1.1.1.11 | Displays the reflected power at the total output in mA. |
| ADTRAN | ADTRAN-GEN-OPTICAL-AMPLIFIER | ADTRAN-GEN-OPTICAL-AMPLIFIER-MIB | adGenOpticalAmplifierInputPower | 1.3.6.1.4.1.664.5.70.41.1.1.1.3 | Input Power of the Optical Signal to the Amplifier module in dBm. |
| ADTRAN | ADTRAN-GEN-OPTICAL-AMPLIFIER | ADTRAN-GEN-OPTICAL-AMPLIFIER-MIB | adGenOpticalAmplifierOutputPower | 1.3.6.1.4.1.664.5.70.41.1.1.1.4 | Output Power of the Optical Signal from the Amplifier module in dBm. |
| ADTRAN | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIB | adGenOpticalADMProvChannelPowerLevel | 1.3.6.1.4.1.664.5.70.43.2.1.1.2 | This OID defines the channel power level reference for all the channels coming in on ADD-IN or EXP-IN interfaces to be auto power balanced. This value will be used when auto power balance is enabled |
| ADTRAN | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIB | adGenOpticalADMProvChannelPower | 1.3.6.1.4.1.664.5.70.43.3.1.1.8 | This OID can be used to set the channel power level. This value will be used if auto power balancing is disabled. The channels coming in on ADD-IN or EXP-IN interfaces will be attenuated to this power level. This is only used when the power control override on the channel level is set to power mode. |
| ADTRAN | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER | ADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIB | adGenOpticalADMChannelStatOcmChannelPower | 1.3.6.1.4.1.664.5.70.43.6.2.1.1 | This displays the Channel current power value of the selected index. |
| ADTRAN | ADTRAN-GENGPON | ADTRAN-GENGPON-MIB | adGenGponOntRxPower | 1.3.6.1.4.1.664.6.10000.76.1.1.3.1.1.32 | The ONT's receive optical signal level. It is a measurement of the OLT's optical launch power (tenths of dBm), received by the ONT's optical transceiver. The default value -9999 indicates that the value is not available. |
| ADTRAN | ADTRAN-GENGPON | ADTRAN-GENGPON-MIB | adGenGponOntTxPower | 1.3.6.1.4.1.664.6.10000.76.1.1.3.1.1.33 | The ONT's transmit optical signal level. It is a measurement of the ONT's optical launch power (tenths of dBm). The default value -9999 indicates that the value is not available. |
| ADTRAN | ADTRAN-GENGPON | ADTRAN-GENGPON-MIB | adGenGponOntVideoReturnPathRxCurrentPower | 1.3.6.1.4.1.664.6.10000.76.1.1.4.7.1.7 | Power level of the last burst received(unit dBmV). |
| ADTRAN | ADTRAN-GENTA8XX | ADTRAN-GENTA8XX-MIB | adGenTA8xxGigEthSFPTxPower | 1.3.6.1.4.1.664.5.69.2.3.3.1.10 | A textual representation of the current transmit power of the SFP. Note that only SFPs that support SFF8472 Release 9.3 or higher support this status. |
| ADTRAN | ADTRAN-GENTA8XX | ADTRAN-GENTA8XX-MIB | adGenTA8xxGigEthSFPRxPower | 1.3.6.1.4.1.664.5.69.2.3.3.1.11 | A textual representation of the current receive power of the SFP. Note that only SFPs that support SFF8472 Release 9.3 or higher support this status. |
| ADTRAN | ADTRAN-PLUGGABLE-PORT | ADTRAN-PLUGGABLE-PORT-MIB | adGenPluggablePortRxPower | 1.3.6.1.4.1.664.5.70.4.1.1.1.21 | Reports the receive power of the pluggable port in units reported by adGenPluggablePortRxPowerUnits. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development. |
| ADTRAN | ADTRAN-PLUGGABLE-PORT | ADTRAN-PLUGGABLE-PORT-MIB | adGenPluggablePortRxPowerUnits | 1.3.6.1.4.1.664.5.70.4.1.1.1.22 | Reports the units of adGenPluggablePortRxPower. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development. |
| ADTRAN | ADTRAN-PLUGGABLE-PORT | ADTRAN-PLUGGABLE-PORT-MIB | adGenPluggablePortTxPower | 1.3.6.1.4.1.664.5.70.4.1.1.1.23 | Reports the transmit power of the pluggable port in units reported by adGenPluggablePortTxPowerUnits. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development. |
| ADTRAN | ADTRAN-TA5K-SM | ADTRAN-TA5K-SM-MIB | adTa5kSmNet1SFPRxPowerLevel | 1.3.6.1.4.1.664.2.750.1.1.1.12 | This displays transceiver RX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions |
| ADTRAN | ADTRAN-TA5K-SM | ADTRAN-TA5K-SM-MIB | adTa5kSmNet1SFPTxPowerLevel | 1.3.6.1.4.1.664.2.750.1.1.1.13 | This displays transceiver TX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions |
| ADTRAN | ADTRAN-TA5K-SM | ADTRAN-TA5K-SM-MIB | adTa5kSmNet2SFPRxPowerLevel | 1.3.6.1.4.1.664.2.750.1.1.1.19 | This displays transceiver RX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions |
| ADTRAN | ADTRAN-TA5K-SM | ADTRAN-TA5K-SM-MIB | adTa5kSmNet2SFPTxPowerLevel | 1.3.6.1.4.1.664.2.750.1.1.1.20 | This displays transceiver TX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions |
| ADVA Optical Networking | ADVA-FSPR7 | ADVA-FSPR7-MIB | physicalPortOutputPower | 1.3.6.1.4.1.2544.1.11.7.3.4.1.1.12 | Instantaneous Optical Power Transmitted (Output) |
| ADVA Optical Networking | ADVA-FSPR7 | ADVA-FSPR7-MIB | virtualPortOutputPower | 1.3.6.1.4.1.2544.1.11.7.3.4.2.1.15 | Instantaneous Optical Power Transmitted (Output) |
| ADVA Optical Networking | ADVA-FSPR7 | ADVA-FSPR7-MIB | pmSnapshotCurrentOutputPower | 1.3.6.1.4.1.2544.1.11.7.7.2.3.1.1 | Instantaneous Optical Power Transmitted (Output). |
| ADVA Optical Networking | ADVA-FSPR7-PM | ADVA-FSPR7-PM-MIB | optMuxPhysInstValueOutputPower | 1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.26 | Instantaneous Optical Power Transmitted (Output) |
| ADVA Optical Networking | ADVA-FSPR7-PM | ADVA-FSPR7-PM-MIB | optMuxPhysInstValueOscOutputPower | 1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.30 | Instantaneous OSC Optical Power Transmitted (Output) |
| ADVA Optical Networking | ADVA-FSPR7-PM | ADVA-FSPR7-PM-MIB | optMuxPhysInstValuePowerPerChannelTx | 1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.32 | Target output optical power for each channel. |
| Alcatel-Lucent Enterprise | ALCATEL-ENT1-PORT | ALCATEL-ENT1-PORT-MIB | ddmTxOutputPower | 1.3.6.1.4.1.6486.801.1.2.1.5.1.1.2.5.1.16 | The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable. |
| Alcatel-Lucent Enterprise | ALCATEL-ENT1-PORT | ALCATEL-ENT1-PORT-MIB | ddmPortTxOutputPower | 1.3.6.1.4.1.6486.801.1.2.1.5.1.1.2.6.1.17 | The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable. |
| Laurel Networks, Inc. | APOLLO | APOLLO-MIB | apolloTrRxPower | 1.3.6.1.4.1.5395.3.7.5.1.5 | Actual Rx Power received on the transceiver.Its value is expressed in dBm |
| Laurel Networks, Inc. | APOLLO | APOLLO-MIB | apolloTrTxPower | 1.3.6.1.4.1.5395.3.7.5.1.6 | Actual Tx Power transmitted on the transceiver.Its value is expressed in dBm |
| Laurel Networks, Inc. | APOLLO | APOLLO-MIB | apolloTrRxPowerLane1 | 1.3.6.1.4.1.5395.3.7.5.1.23 | Rx Power Lane 1. Its value is expressed in dBm |
| Laurel Networks, Inc. | APOLLO | APOLLO-MIB | apolloTrTxPowerLane1 | 1.3.6.1.4.1.5395.3.7.5.1.31 | Tx Power Lane 1. Its value is expressed in dBm |
| Allied Telesis | AT-FIBER-MONITORING | AT-FIBER-MONITORING-MIB | atFiberMonReading | 1.3.6.1.4.1.207.8.4.4.3.27.1.1 | The current received optical power reading for the port specified in the trap (x0.0001mW) |
| Allied Telesis | AT-FIBER-MONITORING | AT-FIBER-MONITORING-MIB | atFiberMonLastReading | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.9 | The most recent reading of rx power, in units of 0.0001mW. -1 is returned if no readings have been taken yet. |
| Allied Telesis | AT-PLUGGABLE-DIAGNOSTICS | AT-PLUGGABLE-DIAGNOSTICS-MIB | atPluggableDiagTxPowerChannel | 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2 | The channel number of the pluggable. |
| Allied Telesis | AT-PLUGGABLE-DIAGNOSTICS | AT-PLUGGABLE-DIAGNOSTICS-MIB | atPluggableDiagTxPowerStatusReading | 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3 | The current Tx Power (mW) status reading. |
| Allied Telesis | AT-PLUGGABLE-DIAGNOSTICS | AT-PLUGGABLE-DIAGNOSTICS-MIB | atPluggableDiagRxPowerStatusReading | 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3 | The current Rx Power (mW) status reading. |
| SynOptics | BAY-STACK-SFF | BAY-STACK-SFF-MIB | bsDdiSfpTxPowerValue | 1.3.6.1.4.1.45.5.29.1.2.1.19 | The actual transmit power value, measured in 1/10000 dBm. |
| SynOptics | BAY-STACK-SFF | BAY-STACK-SFF-MIB | bsDdiSfpRxPowerValue | 1.3.6.1.4.1.45.5.29.1.2.1.24 | The actual receive power value, measured in 1/10000 dBm. |
| Broadcom Limited | BRCM-CM-FACTORY | BRCM-CM-FACTORY-MIB | cmUsCalTxPower | 1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4 | A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used. |
| Brocade | BROCADE-OPTICAL-MONITORING | BROCADE-OPTICAL-MONITORING-MIB | bcsiOptMonLaneTxPower | 1.3.6.1.4.1.1588.3.1.8.1.1.1.4 | This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. |
| Brocade | BROCADE-OPTICAL-MONITORING | BROCADE-OPTICAL-MONITORING-MIB | bcsiOptMonLaneRxPower | 1.3.6.1.4.1.1588.3.1.8.1.1.1.7 | This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. |
| Brocade | BROCADE-OPTICAL-MONITORING | BROCADE-OPTICAL-MONITORING-MIB | bcsiOptMonTxPower | 1.3.6.1.4.1.1588.3.1.8.1.2.1.3 | This object holds the value of the transmitter optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G optic, this returns the aggregated Tx Power for all lanes. |
| Brocade | BROCADE-OPTICAL-MONITORING | BROCADE-OPTICAL-MONITORING-MIB | bcsiOptMonRxPower | 1.3.6.1.4.1.1588.3.1.8.1.2.1.6 | This object holds the value of the receiver optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Rx Power for all lanes. |
| BTI Systems | BTI-7000 | BTI-7000-MIB | oaSSIOpticalPwrReceived | 1.3.6.1.4.1.18070.2.2.1.4.1.1.20 | The optical power received on the second stage of the amplifier. It applies to mid-stage access amplifiers only. |
| BTI Systems | BTI-7000 | BTI-7000-MIB | oaFSOOpticalPwrTransmitted | 1.3.6.1.4.1.18070.2.2.1.4.1.1.34 | The optical power transmitted at the output of the first stage of the amplifier. It applies to mid-stage access amplifiers only. |
| BTI Systems | BTI-7000 | BTI-7000-MIB | amdOpticalPwrTransmitted | 1.3.6.1.4.1.18070.2.2.1.4.3.1.11 | The optical power level transmitted for the channel. |
| BTI Systems | BTI-OL | BTI-OL-MIB | olOSCCrntPMOPRValue | 1.3.6.1.4.1.18070.2.2.1.16.12.1.1.6 | The OSC optical power received on the Line port. |
| BTI Systems | BTI-OL | BTI-OL-MIB | olOSCCrntPMOPTValue | 1.3.6.1.4.1.18070.2.2.1.16.12.1.1.9 | The OSC optical power transmitted at the output of the Line port. |
| BTI Systems | BTI-OL | BTI-OL-MIB | wchCrntPMOPTValue | 1.3.6.1.4.1.18070.2.2.1.16.12.6.1.19 | The instantaneous optical power transmitted on the channel. |
| BTI Systems | BTI-OL | BTI-OL-MIB | wchCrntPMOPRValue | 1.3.6.1.4.1.18070.2.2.1.16.12.6.1.8 | The instantaneous optical power received on the channel. |
| Casa Systems, Inc. | CASA-SFP | CASA-SFP-MIB | casaSfpTxPower | 1.3.6.1.4.1.20858.10.37.1.1.1.7 | The optical Tx power of the sfp(sfp+). |
| Casa Systems, Inc. | CASA-SFP | CASA-SFP-MIB | casaSfpRxPower | 1.3.6.1.4.1.20858.10.37.1.1.1.8 | The optical Rx power of the sfp(sfp+). |
| Cerent (Cisco optical) | CERENT-MSDWDM | CERENT-MSDWDM-MIB | cMsDwdmIfTransportAddPower | 1.3.6.1.4.1.3607.2.40.1.2.1.16 | This object is used to specify the ADD optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource. |
| Cerent (Cisco optical) | CERENT-MSDWDM | CERENT-MSDWDM-MIB | cMsDwdmIfTransportOSCPower | 1.3.6.1.4.1.3607.2.40.1.2.1.17 | This object is used to specify the OSC optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource. |
| Cerent (Cisco optical) | CERENT-MSDWDM | CERENT-MSDWDM-MIB | cMsDwdmIfChannelPower | 1.3.6.1.4.1.3607.2.40.1.4.1.3 | This object is used to specify the optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource. |
| Ciena | CIENA-CES-PM | CIENA-CES-PM | cienaCesPmBasicPtpCurrBinOptOch | 1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.12 | Optical Power Transmit, Optical Channel. |
| Ciena | CIENA-CES-PM | CIENA-CES-PM | cienaCesPmBasicPtpCurrBinOprnOts | 1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.17 | Total Normalized Optical Power Receive, Optical Channel. |
| Ciena | CIENA-CES-PM | CIENA-CES-PM | cienaCesPmBasicPtpCurrBinOprnOch | 1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.8 | Normalized Optical Power Receive, Optical Channel. |
| Ciena | CIENA-CES-PM | CIENA-CES-PM | cienaCesPmBasicPtpTotalStatsBinOptOch | 1.3.6.1.4.1.1271.2.3.1.2.3.13.6.1.7 | Optical Power Transmit, Optical Channel. |
| Ciena | CIENA-WS-PM | CIENA-WS-PM-MIB | cwsPmBasicCurrentOpticalRxPowerActual | 1.3.6.1.4.1.1271.3.4.22.68.1.2 | Actual power reading. |
| Ciena | CIENA-WS-PTP | CIENA-WS-PTP-MIB | cwsXcvrRxPowerActual | 1.3.6.1.4.1.1271.3.4.8.11.1.2 | Actual Tx or Rx optical power in dBm. |
| Ciena | CIENA-WS-PTP | CIENA-WS-PTP-MIB | cwsXcvrTxPowerActual | 1.3.6.1.4.1.1271.3.4.8.13.1.2 | Actual Tx or Rx optical power in dBm. |
| Ciena | CIENA-WS-PTP-MODEM | CIENA-WS-PTP-MODEM-MIB | cwsXcvrColourlessRxChannelPowerActual | 1.3.6.1.4.1.1271.3.4.9.26.1.2 | Actual Tx or Rx optical power in dBm. |
| Ciena | CIENA-WS-XCVR | CIENA-WS-XCVR-MIB | cwsXcvrVendorDiagnosticMonitoringRxPowerMeasurement | 1.3.6.1.4.1.1271.3.4.15.12.1.2 | Rx power measurement, bit 3 of diagnostic monitoring type. Reference SFF 8472 section 8.8 and table 9.5 for detail. |
| Ciena | CIENA-WS-XCVR | CIENA-WS-XCVR-MIB | cwsXcvrVendorDiagnosticMonitoringTxPowerMeasurement | 1.3.6.1.4.1.1271.3.4.15.12.1.3 | Tx ower measurement, related to diagnostic monitoring type. |
| Ciena | CIENA-WS-XCVR | CIENA-WS-XCVR-MIB | cwsXcvrChannelRxPowerActual | 1.3.6.1.4.1.1271.3.4.15.17.1.2 | Actual Rx optical power in dBm. |
| Ciena | CIENA-WS-XCVR | CIENA-WS-XCVR-MIB | cwsXcvrChannelTxPowerActual | 1.3.6.1.4.1.1271.3.4.15.20.1.2 | Actual Tx optical power in dBm. |
| Cisco | CISCO-LWAPP-CCX-RM | CISCO-LWAPP-CCX-RM-MIB | clcrClientRxPowerSignal | 1.3.6.1.4.1.9.9.520.1.4.1.1.2 | This object represents the signal strength of the beacon or probe response frame as seen by the client. |
| Cisco | CISCO-OPTICAL | CISCO-OPTICAL-MIB | coiOpticalControllerTransmitPower | 1.3.6.1.4.1.9.9.828.1.1.2.1.5 | This object is used to configure the Transmit Power in 1/100 dBm on optical channel interfaces. |
| Cisco | CISCO-OPTICAL | CISCO-OPTICAL-MIB | coiOpticalControllerPerLaneRXPower | 1.3.6.1.4.1.9.9.828.1.1.3.1.2 | This object specifies the Receive power in 1/100 dBm. |
| Cisco | CISCO-OPTICAL | CISCO-OPTICAL-MIB | coiOpticalControllerPerLaneTXPower | 1.3.6.1.4.1.9.9.828.1.1.3.1.3 | This object specifies the Transmit power in 1/100 dBm. |
| Cisco | CISCO-OPTICAL-MONITORING | CISCO-OPTICAL-MONITORING-MIB | comTxPower | 1.3.6.1.4.1.9.10.83.1.1.1.1.3 | This object holds the value of the transmitter optical power for the interface being instrumented. The optical is proportional to the laser diode current. This object makes sense only if comTxPowerSupported is true. All values must be converted to microWatts. |
| Cisco | CISCO-OPTICAL-OTS | CISCO-OPTICAL-OTS-MIB | cooOtsOchControllerTXPower | 1.3.6.1.4.1.9.9.834.1.1.3.1.4 | This object represents the transmit power in 1/100 dBm on optical OTS-OCH interfaces. |
| Cisco | CISCO-OPTICAL-OTS | CISCO-OPTICAL-OTS-MIB | cooOtsControllerTotalRXPower | 1.3.6.1.4.1.9.9.834.1.1.2.1.7 | This object is used to represents the total receive power in 1/100 dBm on optical OTS interfaces. |
| Cisco | CISCO-OPTICAL-OTS | CISCO-OPTICAL-OTS-MIB | cooOtsControllerTotalTXPower | 1.3.6.1.4.1.9.9.834.1.1.2.1.8 | This object is used to represents the total transmit power in 1/100 dBm on optical OTS interfaces. |
| ADVA Optical Networking | CM-PERFORMANCE | CM-PERFORMANCE-MIB | cmEthernetNetPortStatsOPT | 1.3.6.1.4.1.2544.1.12.5.1.5.1.33 | Optical Power Transmit (in dBm) for the physical layer. This is applicable only if the media type for the Network Port is fiber. |
| ADVA Optical Networking | CM-PERFORMANCE | CM-PERFORMANCE-MIB | cmEthernetNetPortStatsOPR | 1.3.6.1.4.1.2544.1.12.5.1.5.1.34 | Optical Power Receive (in dBm) for the physical layer. This is applicable only if the media type for the Network Port is fiber. |
| ADVA Optical Networking | CM-PERFORMANCE | CM-PERFORMANCE-MIB | ocnStmStatsLineOPT | 1.3.6.1.4.1.2544.1.12.5.1.46.1.6 | Transmit Optical Power retrieved from the SFP. |
| ADVA Optical Networking | CM-PERFORMANCE | CM-PERFORMANCE-MIB | ocnStmStatsLineOPR | 1.3.6.1.4.1.2544.1.12.5.1.46.1.7 | Received Optical Power retrieved from the SFP. |
| Pepperl+Fuchs Comtrol | COMTROL-ES8510 | COMTROL-ES8510-MIB | portSfpDdmTxPowerCurrent | 1.3.6.1.4.1.2882.2.1.1.3.2.2.1.7 | The current SFP Transmitted Power of port. |
| Pepperl+Fuchs Comtrol | COMTROL-ES8510 | COMTROL-ES8510-MIB | portSfpDdmRxPowerCurrent | 1.3.6.1.4.1.2882.2.1.1.3.2.2.1.9 | The current SFP Receiveed Power of port. |
| Check Point Software Technologies | CPVIEW | CPVIEW-MIB | orchestratorPortsPortsTableRxPowerLanes | 1.3.6.1.4.1.2620.1.56.302.1.1.29 | No description published. |
| Check Point Software Technologies | CPVIEW | CPVIEW-MIB | orchestratorPortsPortsTableTxPowerLanes | 1.3.6.1.4.1.2620.1.56.302.1.1.30 | No description published. |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f100ISDDTxPWRRemoteA | 1.3.6.1.4.1.4756.20.181.20.1.49 | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Tx power |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f100ISDDRxPWRRemoteA | 1.3.6.1.4.1.4756.20.181.20.1.50 | RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx power |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f10GMUXLineDDTxPWRLocal | 1.3.6.1.4.1.4756.20.700.20.1.106 | Local FRM220-TM-10GMUX card Line D/D information: Tx power |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f10GMUXLineDDRxPWRLocal | 1.3.6.1.4.1.4756.20.700.20.1.107 | Local FRM220-TM-10GMUX card Line D/D information: Rx power |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f100GE2QClient3TxPower | 1.3.6.1.4.1.4756.20.710.20.1.101 | Local FRM220-100GE-2Q Line Card Client3 Transmit Power. |
| CTC Union | CTC-FRM220 | CTC-FRM220-MIB | f100GE2QClient3RxPower | 1.3.6.1.4.1.4756.20.710.20.1.102 | Local FRM220-100GE-2Q Line Card Client3 Receive Power. |
| Cyan Inc. | CYAN-GEPORT | CYAN-GEPORT-MIB | cyanGEPortRxPwr | 1.3.6.1.4.1.28533.5.30.160.1.1.1.13 | RX Power |
| Cyan Inc. | CYAN-GEPORT | CYAN-GEPORT-MIB | cyanGEPortTxPwr | 1.3.6.1.4.1.28533.5.30.160.1.1.1.16 | TX Power |
| Cyan Inc. | CYAN-TENGPORT | CYAN-TENGPORT-MIB | cyanTENGPortRxPwr | 1.3.6.1.4.1.28533.5.30.150.1.1.1.14 | RX Power |
| Cyan Inc. | CYAN-TENGPORT | CYAN-TENGPORT-MIB | cyanTENGPortTxPwr | 1.3.6.1.4.1.28533.5.30.150.1.1.1.18 | TX Power |
| Dasan Zhone | DASAN-GIGABIT-OPTIC-TRANSCEIVER | DASAN-GIGABIT-OPTIC-TRANSCEIVER-MIB | dsGOTransceiverDiagTxPower | 1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.4 | Measured TX output power. |
| Dasan Zhone | DASAN-GIGABIT-OPTIC-TRANSCEIVER | DASAN-GIGABIT-OPTIC-TRANSCEIVER-MIB | dsGOTransceiverDiagRxPower | 1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.5 | Measured RX input power. |
| DCN (Digital China Networks) | DCN | DCN-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.6339.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| DCN (Digital China Networks) | DCN | DCN-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.6339.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| D-Link | DDM-MGMT | DDM-MGMT-MIB | swDdmTxPower | 1.3.6.1.4.1.171.12.72.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DDM-MGMT | DDM-MGMT-MIB | swDdmRxPower | 1.3.6.1.4.1.171.12.72.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| Dell (Force10) | DELL-NETWORKING-CHASSIS | DELL-NETWORKING-CHASSIS-MIB | dellNetSysIfXfpTxPower | 1.3.6.1.4.1.6027.3.26.1.4.10.1.7 | The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. |
| D-Link | DES-1210-10MEbx | DES-1210-10MEbx | ddmTxPower | 1.3.6.1.4.1.171.10.75.14.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-10MEbx | DES-1210-10MEbx | ddmRxPower | 1.3.6.1.4.1.171.10.75.14.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-26ME-B2 | DES-1210-26ME-B2 | ddmTxPower | 1.3.6.1.4.1.171.10.75.16.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-26ME-B2 | DES-1210-26ME-B2 | ddmRxPower | 1.3.6.1.4.1.171.10.75.16.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-28ME-B2 | DES-1210-28ME-B2 | ddmTxPower | 1.3.6.1.4.1.171.10.75.15.2.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-28ME-B2 | DES-1210-28ME-B2 | ddmRxPower | 1.3.6.1.4.1.171.10.75.15.2.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-28ME-B3 | DES-1210-28ME-B3 | ddmTxPower | 1.3.6.1.4.1.171.10.75.15.3.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DES-1210-28ME-B3 | DES-1210-28ME-B3 | ddmRxPower | 1.3.6.1.4.1.171.10.75.15.3.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-10ME_AX | DGS-1210-10ME_AX | ddmTxPower | 1.3.6.1.4.1.171.10.76.32.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-10ME_AX | DGS-1210-10ME_AX | ddmRxPower | 1.3.6.1.4.1.171.10.76.32.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-12TSME-BX | DGS-1210-12TSME-BX | ddmTxPower | 1.3.6.1.4.1.171.10.76.44.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-12TSME-BX | DGS-1210-12TSME-BX | ddmRxPower | 1.3.6.1.4.1.171.10.76.44.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-20ME_AX | DGS-1210-20ME_AX | ddmTxPower | 1.3.6.1.4.1.171.10.76.31.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-20ME_AX | DGS-1210-20ME_AX | ddmRxPower | 1.3.6.1.4.1.171.10.76.31.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28ME_AX | DGS-1210-28ME_AX | ddmTxPower | 1.3.6.1.4.1.171.10.76.28.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28ME_AX | DGS-1210-28ME_AX | ddmRxPower | 1.3.6.1.4.1.171.10.76.28.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28PME_AX | DGS-1210-28PME_AX | ddmTxPower | 1.3.6.1.4.1.171.10.76.30.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28PME_AX | DGS-1210-28PME_AX | ddmRxPower | 1.3.6.1.4.1.171.10.76.30.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28XME-BX | DGS-1210-28XME-BX | ddmTxPower | 1.3.6.1.4.1.171.10.76.43.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28XME-BX | DGS-1210-28XME-BX | ddmRxPower | 1.3.6.1.4.1.171.10.76.43.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28XSME-BX | DGS-1210-28XSME-BX | ddmTxPower | 1.3.6.1.4.1.171.10.76.39.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-28XSME-BX | DGS-1210-28XSME-BX | ddmRxPower | 1.3.6.1.4.1.171.10.76.39.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-52ME_AX | DGS-1210-52ME_AX | ddmTxPower | 1.3.6.1.4.1.171.10.76.29.1.105.2.1.1.1.5 | This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter. |
| D-Link | DGS-1210-52ME_AX | DGS-1210-52ME_AX | ddmRxPower | 1.3.6.1.4.1.171.10.76.29.1.105.2.1.1.1.6 | This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter. |
| D-Link | DLINKSW-DDM | DLINKSW-DDM-MIB | dDdmIfInfoCurrentTxPower | 1.3.6.1.4.1.171.14.72.1.4.1.1.19 | This object indicates the current output power in unit of 'tenths of a microwatt' on the interface. |
| D-Link | DLINKSW-DDM | DLINKSW-DDM-MIB | dDdmIfInfoCurrentRxPower | 1.3.6.1.4.1.171.14.72.1.4.1.1.25 | This object indicates the current input power in unit of 'tenths of a microwatt' on the interface. |
| Datacom (Teracom Telematica Ltda.) | DMswitch | DMswitch-MIB | ddTransceiversTxPowerValue | 1.3.6.1.4.1.3709.3.5.201.1.28.1.1.10 | Transceiver tx power infomation |
| Datacom (Teracom Telematica Ltda.) | DMswitch | DMswitch-MIB | ddTransceiversRxPower | 1.3.6.1.4.1.3709.3.5.201.1.28.1.1.4 | Transceiver rx power information in Decibels |
| Datacom (Teracom Telematica Ltda.) | DMswitch | DMswitch-MIB | ddTransceiversTxPower | 1.3.6.1.4.1.3709.3.5.201.1.28.1.1.5 | Transceiver tx power information in Decibels |
| Datacom (Teracom Telematica Ltda.) | DMswitch | DMswitch-MIB | ddTransceiversRxPowerValue | 1.3.6.1.4.1.3709.3.5.201.1.28.1.1.9 | Transceiver rx power infomation |
| Actelis Networks | E5-110 | E5-110-MIB | enetSfpInfoTxpower | 1.3.6.1.4.1.6321.1.2.3.1.13.17.2.1.1 | Measured Tx Output Power. |
| Actelis Networks | E5-110 | E5-110-MIB | enetSfpInfoRxpower | 1.3.6.1.4.1.6321.1.2.3.1.13.17.2.1.2 | Measured Rx Output Power. |
| Actelis Networks | E5-111 | E5-111-MIB | enetSfpInfoTxpower | 1.3.6.1.4.1.6321.1.2.3.2.13.17.2.1.1 | Measured Tx Output Power. |
| Actelis Networks | E5-111 | E5-111-MIB | enetSfpInfoRxpower | 1.3.6.1.4.1.6321.1.2.3.2.13.17.2.1.2 | Measured Rx Output Power. |
| Actelis Networks | E5-120 | E5-120-MIB | enetSfpInfoTxpower | 1.3.6.1.4.1.6321.1.2.3.3.13.16.2.1.1 | Measured Tx Output Power. |
| Actelis Networks | E5-120 | E5-120-MIB | enetSfpInfoRxpower | 1.3.6.1.4.1.6321.1.2.3.3.13.16.2.1.2 | Measured Rx Output Power. |
| Actelis Networks | E5-120 | E5-120-MIB | ldmXturAggregateTxPower | 1.3.6.1.4.1.6321.1.2.3.3.4.4.12 | Actual Aggregate Transmit Power. |
| Actelis Networks | E5-120 | E5-120-MIB | ldmXtucAggregateTxPower | 1.3.6.1.4.1.6321.1.2.3.3.4.4.7 | Actual Aggregate Transmit Power. |
| Actelis Networks | E5-121 | E5-121-MIB | enetSfpInfoTxpower | 1.3.6.1.4.1.6321.1.2.3.4.13.16.2.1.1 | Measured Tx Output Power. |
| Actelis Networks | E5-121 | E5-121-MIB | enetSfpInfoRxpower | 1.3.6.1.4.1.6321.1.2.3.4.13.16.2.1.2 | Measured Rx Output Power. |
| Actelis Networks | E5-121 | E5-121-MIB | ldmXturAggregateTxPower | 1.3.6.1.4.1.6321.1.2.3.4.4.4.12 | Actual Aggregate Transmit Power. |
| Actelis Networks | E5-121 | E5-121-MIB | ldmXtucAggregateTxPower | 1.3.6.1.4.1.6321.1.2.3.4.4.4.7 | Actual Aggregate Transmit Power. |
| Ekinops | EKINOPS-Pm10001otu4 | EKINOPS-Pm10001otu4-MIB | pm10001otu4MesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.82.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10001otu4 | EKINOPS-Pm10001otu4-MIB | pm10001otu4MesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.82.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10001otu4 | EKINOPS-Pm10001otu4-MIB | pm10001otu4MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.82.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10001otu4 | EKINOPS-Pm10001otu4-MIB | pm10001otu4MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.82.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mp | EKINOPS-Pm10010mp-MIB | pm10010mpMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.58.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mp | EKINOPS-Pm10010mp-MIB | pm10010mpMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.58.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mp | EKINOPS-Pm10010mp-MIB | pm10010mpMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.58.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mp | EKINOPS-Pm10010mp-MIB | pm10010mpMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.58.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mpt | EKINOPS-Pm10010mpt-MIB | pm10010mptMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.60.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mpt | EKINOPS-Pm10010mpt-MIB | pm10010mptMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.60.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mpt | EKINOPS-Pm10010mpt-MIB | pm10010mptMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.60.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mpt | EKINOPS-Pm10010mpt-MIB | pm10010mptMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.60.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mr | EKINOPS-Pm10010mr-MIB | pm10010mrMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.63.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mr | EKINOPS-Pm10010mr-MIB | pm10010mrMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.63.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010mr | EKINOPS-Pm10010mr-MIB | pm10010mrMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.63.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010mr | EKINOPS-Pm10010mr-MIB | pm10010mrMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.63.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010ulh | EKINOPS-Pm10010ulh-MIB | pm10010ulhMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.80.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010ulh | EKINOPS-Pm10010ulh-MIB | pm10010ulhMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.80.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm10010ulh | EKINOPS-Pm10010ulh-MIB | pm10010ulhMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.80.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm10010ulh | EKINOPS-Pm10010ulh-MIB | pm10010ulhMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.80.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm1001IM | EKINOPS-Pm1001IM-MIB | pm1001imMesrclientTxPowerMeas | 1.3.6.1.4.1.20044.15.3.2.211 | Client XFP Transmitted Power :This OID gives the transmit power value of the XFP or OTX plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1001IM | EKINOPS-Pm1001IM-MIB | pm1001imMesrclientRxPowerMeas | 1.3.6.1.4.1.20044.15.3.2.212 | Client XFP Received Power :This OID gives the receive power value of the XFP or OTX plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1001IM | EKINOPS-Pm1001IM-MIB | pm1001imMesrlineTxpwrMeasPortn | 1.3.6.1.4.1.20044.15.3.3.40.1.2 | Line SFP Transmitted Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1001IM | EKINOPS-Pm1001IM-MIB | pm1001imMesrlineRxpwrMeasPortn | 1.3.6.1.4.1.20044.15.3.3.48.1.2 | Line SFP Received Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-PM1001LH | EKINOPS-PM1001LH-MIB | pm1001lhMesrclientTxPowerMeas | 1.3.6.1.4.1.20044.10.3.2.40 | Client Optical Module Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-PM1001LH | EKINOPS-PM1001LH-MIB | pm1001lhMesrclientRxPowerMeas | 1.3.6.1.4.1.20044.10.3.2.48 | Client Optical Module Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-PM1001LH | EKINOPS-PM1001LH-MIB | pm1001lhMesrlineTxPowerMeas | 1.3.6.1.4.1.20044.10.3.3.211 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-PM1001LH | EKINOPS-PM1001LH-MIB | pm1001lhMesrlineRxPowerMeas | 1.3.6.1.4.1.20044.10.3.3.212 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1001lhr | EKINOPS-Pm1001lhr-MIB | pm1001lhrMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.22.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1001lhr | EKINOPS-Pm1001lhr-MIB | pm1001lhrMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.22.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-PM1001PC | EKINOPS-PM1001PC-MIB | pm1001pcMesrclientTxPowerMeas | 1.3.6.1.4.1.20044.12.3.2.40 | Client Optical Module Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-PM1001PC | EKINOPS-PM1001PC-MIB | pm1001pcMesrclientRxPowerMeas | 1.3.6.1.4.1.20044.12.3.2.48 | Client Optical Module Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-PM1001PC | EKINOPS-PM1001PC-MIB | pm1001pcMesrlineTxPowerMeas | 1.3.6.1.4.1.20044.12.3.3.211 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-PM1001PC | EKINOPS-PM1001PC-MIB | pm1001pcMesrlineRxPowerMeas | 1.3.6.1.4.1.20044.12.3.3.212 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1001RR | EKINOPS-Pm1001RR-MIB | pm1001rrMesrclientTxPower | 1.3.6.1.4.1.20044.8.3.2.19 | Line 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm1001RR | EKINOPS-Pm1001RR-MIB | pm1001rrMesrclientRxPower | 1.3.6.1.4.1.20044.8.3.2.20 | Line 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm1001RR | EKINOPS-Pm1001RR-MIB | pm1001rrMesrlineTxPower | 1.3.6.1.4.1.20044.8.3.3.27 | Line 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm1001RR | EKINOPS-Pm1001RR-MIB | pm1001rrMesrlineRxPower | 1.3.6.1.4.1.20044.8.3.3.28 | Line 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm1004 | EKINOPS-Pm1004-MIB | pm1004MesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.18.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004 | EKINOPS-Pm1004-MIB | pm1004MesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.18.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004 | EKINOPS-Pm1004-MIB | pm1004Mesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.18.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceive r |
| Ekinops | EKINOPS-Pm1004 | EKINOPS-Pm1004-MIB | pm1004Mesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.18.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004dcp | EKINOPS-Pm1004dcp-MIB | pm1004dcpMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.37.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004dcp | EKINOPS-Pm1004dcp-MIB | pm1004dcpMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.37.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004dcp | EKINOPS-Pm1004dcp-MIB | pm1004dcpMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.37.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004dcp | EKINOPS-Pm1004dcp-MIB | pm1004dcpMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.37.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004m | EKINOPS-Pm1004m-MIB | pm1004mMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.29.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004m | EKINOPS-Pm1004m-MIB | pm1004mMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.29.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004m | EKINOPS-Pm1004m-MIB | pm1004mMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.29.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004m | EKINOPS-Pm1004m-MIB | pm1004mMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.29.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004V | EKINOPS-Pm1004V-MIB | pm1004vMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.32.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004V | EKINOPS-Pm1004V-MIB | pm1004vMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.32.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004V | EKINOPS-Pm1004V-MIB | pm1004vMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.32.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004V | EKINOPS-Pm1004V-MIB | pm1004vMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.32.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004VDC | EKINOPS-Pm1004VDC-MIB | pm1004vdcMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.38.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004VDC | EKINOPS-Pm1004VDC-MIB | pm1004vdcMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.38.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1004VDC | EKINOPS-Pm1004VDC-MIB | pm1004vdcMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.38.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004VDC | EKINOPS-Pm1004VDC-MIB | pm1004vdcMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.38.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004venc | EKINOPS-Pm1004venc-MIB | pm1004vencMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.43.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1004venc | EKINOPS-Pm1004venc-MIB | pm1004vencMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.43.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1005 | EKINOPS-Pm1005-MIB | pm1005MesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.26.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1005 | EKINOPS-Pm1005-MIB | pm1005MesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.26.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1005 | EKINOPS-Pm1005-MIB | pm1005Mesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.26.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1005 | EKINOPS-Pm1005-MIB | pm1005Mesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.26.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1008 | EKINOPS-Pm1008-MIB | pm1008MesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.3.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1008 | EKINOPS-Pm1008-MIB | pm1008MesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.3.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1008 | EKINOPS-Pm1008-MIB | pm1008Mesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.3.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1008 | EKINOPS-Pm1008-MIB | pm1008Mesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.3.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1008DCP | EKINOPS-Pm1008DCP-MIB | pm1008dcpMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.27.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1008DCP | EKINOPS-Pm1008DCP-MIB | pm1008dcpMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.27.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm1008DCP | EKINOPS-Pm1008DCP-MIB | pm1008dcpMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.27.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1008DCP | EKINOPS-Pm1008DCP-MIB | pm1008dcpMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.27.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm100gagg | EKINOPS-Pm100gagg-MIB | pm100gaggMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.91.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gagg | EKINOPS-Pm100gagg-MIB | pm100gaggMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.91.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gagg | EKINOPS-Pm100gagg-MIB | pm100gaggMesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.91.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gagg | EKINOPS-Pm100gagg-MIB | pm100gaggMesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.91.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gemux | EKINOPS-Pm100gemux-MIB | pm100gemuxMesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.103.3.2.256.1.2 | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gemux | EKINOPS-Pm100gemux-MIB | pm100gemuxMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.103.3.2.272.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gemux | EKINOPS-Pm100gemux-MIB | pm100gemuxMesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.103.3.2.288.1.2 | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gemux | EKINOPS-Pm100gemux-MIB | pm100gemuxMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.103.3.2.304.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gemuxsfp | EKINOPS-Pm100gemuxsfp-MIB | pm100gemuxsfpMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.107.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gemuxsfp | EKINOPS-Pm100gemuxsfp-MIB | pm100gemuxsfpMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.107.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gemuxsfp | EKINOPS-Pm100gemuxsfp-MIB | pm100gemuxsfpMesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.107.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gemuxsfp | EKINOPS-Pm100gemuxsfp-MIB | pm100gemuxsfpMesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.107.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gfmuxd | EKINOPS-Pm100gfmuxd-MIB | pm100gfmuxdMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.111.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gfmuxd | EKINOPS-Pm100gfmuxd-MIB | pm100gfmuxdMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.111.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gfmuxd | EKINOPS-Pm100gfmuxd-MIB | pm100gfmuxdMesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.111.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gfmuxd | EKINOPS-Pm100gfmuxd-MIB | pm100gfmuxdMesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.111.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gxponder | EKINOPS-Pm100gxponder-MIB | pm100gxponderMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.113.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gxponder | EKINOPS-Pm100gxponder-MIB | pm100gxponderMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.113.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm100gxponder | EKINOPS-Pm100gxponder-MIB | pm100gxponderMesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.113.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm100gxponder | EKINOPS-Pm100gxponder-MIB | pm100gxponderMesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.113.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pm124 | EKINOPS-Pm124-MIB | pm124MesrclientTxPowerPortn | 1.3.6.1.4.1.20044.16.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm124 | EKINOPS-Pm124-MIB | pm124MesrclientRxPowerPortn | 1.3.6.1.4.1.20044.16.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm124 | EKINOPS-Pm124-MIB | pm124MesrlineTxPowerPortn | 1.3.6.1.4.1.20044.16.3.3.67.1.2 | Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm124 | EKINOPS-Pm124-MIB | pm124MesrlineRxPowerPortn | 1.3.6.1.4.1.20044.16.3.3.68.1.2 | Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm124fe | EKINOPS-Pm124fe-MIB | pm124feMesrclientTxPowerPortn | 1.3.6.1.4.1.20044.44.3.2.40.1.2 | Client SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm124fe | EKINOPS-Pm124fe-MIB | pm124feMesrclientRxPowerPortn | 1.3.6.1.4.1.20044.44.3.2.48.1.2 | Client SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm124fe | EKINOPS-Pm124fe-MIB | pm124feMesrlineTxPowerPortn | 1.3.6.1.4.1.20044.44.3.3.67.1.2 | Line SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm124fe | EKINOPS-Pm124fe-MIB | pm124feMesrlineRxPowerPortn | 1.3.6.1.4.1.20044.44.3.3.68.1.2 | Line SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm1604 | EKINOPS-Pm1604-MIB | pm1604Mesrline1TxPowerPortn | 1.3.6.1.4.1.20044.77.3.2.40.1.2 | Line 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm1604 | EKINOPS-Pm1604-MIB | pm1604Mesrline1RxPowerPortn | 1.3.6.1.4.1.20044.77.3.2.48.1.2 | Line 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm1604 | EKINOPS-Pm1604-MIB | pm1604Mesrline2TxPowerPortn | 1.3.6.1.4.1.20044.77.3.3.44.1.2 | Line 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm1604 | EKINOPS-Pm1604-MIB | pm1604Mesrline2RxPowerPortn | 1.3.6.1.4.1.20044.77.3.3.52.1.2 | Line 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm20002ma | EKINOPS-Pm20002ma-MIB | pm20002maMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.73.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm20002ma | EKINOPS-Pm20002ma-MIB | pm20002maMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.73.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm20020ma | EKINOPS-Pm20020ma-MIB | pm20020maMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.69.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm20020ma | EKINOPS-Pm20020ma-MIB | pm20020maMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.69.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm20020ma | EKINOPS-Pm20020ma-MIB | pm20020maMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.69.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm20020ma | EKINOPS-Pm20020ma-MIB | pm20020maMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.69.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm200fr20 | EKINOPS-Pm200fr20-MIB | pm200fr20MesrclientRxPwrPortn | 1.3.6.1.4.1.20044.87.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm200fr20 | EKINOPS-Pm200fr20-MIB | pm200fr20MesrclientTxPwrPortn | 1.3.6.1.4.1.20044.87.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pm200fr20 | EKINOPS-Pm200fr20-MIB | pm200fr20MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.87.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm200fr20 | EKINOPS-Pm200fr20-MIB | pm200fr20MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.87.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm200frs02 | EKINOPS-Pm200frs02-MIB | pm200frs02MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.90.3.2.256.1.2 | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm200frs02 | EKINOPS-Pm200frs02-MIB | pm200frs02MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.90.3.2.288.1.2 | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm200frs02 | EKINOPS-Pm200frs02-MIB | pm200frs02MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.90.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm200frs02 | EKINOPS-Pm200frs02-MIB | pm200frs02MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.90.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm251d | EKINOPS-Pm251d-MIB | pm251dMesrclientTxpwrMeasPortn | 1.3.6.1.4.1.20044.31.3.2.40.1.2 | Client SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm251d | EKINOPS-Pm251d-MIB | pm251dMesrclientRxpwrMeasPortn | 1.3.6.1.4.1.20044.31.3.2.48.1.2 | Client SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm251d | EKINOPS-Pm251d-MIB | pm251dMesrlineTxpwrMeasPortn | 1.3.6.1.4.1.20044.31.3.3.163.1.2 | Line SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm251d | EKINOPS-Pm251d-MIB | pm251dMesrlineRxpwrMeasPortn | 1.3.6.1.4.1.20044.31.3.3.164.1.2 | Line SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm253 | EKINOPS-Pm253-MIB | pm253MesrclientTxpwrMeasPortn | 1.3.6.1.4.1.20044.13.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm253 | EKINOPS-Pm253-MIB | pm253MesrclientRxpwrMeasPortn | 1.3.6.1.4.1.20044.13.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm253 | EKINOPS-Pm253-MIB | pm253MesrlineTxpwrMeasPortn | 1.3.6.1.4.1.20044.13.3.3.163.1.2 | Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm253 | EKINOPS-Pm253-MIB | pm253MesrlineRxpwrMeasPortn | 1.3.6.1.4.1.20044.13.3.3.164.1.2 | Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm254d | EKINOPS-Pm254d-MIB | pm254dMesrclientTxpwrMeasPortn | 1.3.6.1.4.1.20044.17.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm254d | EKINOPS-Pm254d-MIB | pm254dMesrclientRxpwrMeasPortn | 1.3.6.1.4.1.20044.17.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pm254d | EKINOPS-Pm254d-MIB | pm254dMesrlineTxpwrMeasPortn | 1.3.6.1.4.1.20044.17.3.3.163.1.2 | Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm254d | EKINOPS-Pm254d-MIB | pm254dMesrlineRxpwrMeasPortn | 1.3.6.1.4.1.20044.17.3.3.164.1.2 | Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pm400fr05 | EKINOPS-Pm400fr05-MIB | pm400fr05MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.118.3.2.256.1.2 | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm400fr05 | EKINOPS-Pm400fr05-MIB | pm400fr05MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.118.3.2.288.1.2 | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm400fr05 | EKINOPS-Pm400fr05-MIB | pm400fr05MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.118.3.3.144.1.2 | Current Line Trscv Tx Laser Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the current Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm400frs04 | EKINOPS-Pm400frs04-MIB | pm400frs04MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.100.3.2.256.1.2 | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm400frs04 | EKINOPS-Pm400frs04-MIB | pm400frs04MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.100.3.2.288.1.2 | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm400frs04 | EKINOPS-Pm400frs04-MIB | pm400frs04MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.100.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm400frs04 | EKINOPS-Pm400frs04-MIB | pm400frs04MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.100.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm404 | EKINOPS-Pm404-MIB | pm404Mesrline1TxPowerPortn | 1.3.6.1.4.1.20044.25.3.2.40.1.2 | Line 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm404 | EKINOPS-Pm404-MIB | pm404Mesrline1RxPowerPortn | 1.3.6.1.4.1.20044.25.3.2.48.1.2 | Line 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm404 | EKINOPS-Pm404-MIB | pm404Mesrline2TxPowerPortn | 1.3.6.1.4.1.20044.25.3.3.44.1.2 | Line 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm404 | EKINOPS-Pm404-MIB | pm404Mesrline2RxPowerPortn | 1.3.6.1.4.1.20044.25.3.3.52.1.2 | Line 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm600frs06 | EKINOPS-Pm600frs06-MIB | pm600frs06MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.115.3.2.256.1.2 | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm600frs06 | EKINOPS-Pm600frs06-MIB | pm600frs06MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.115.3.2.288.1.2 | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm600frs06 | EKINOPS-Pm600frs06-MIB | pm600frs06MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.115.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm600frs06 | EKINOPS-Pm600frs06-MIB | pm600frs06MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.115.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm800fr04 | EKINOPS-Pm800fr04-MIB | pm800fr04MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.120.3.2.256.1.2 | Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-30) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm800fr04 | EKINOPS-Pm800fr04-MIB | pm800fr04MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.120.3.2.288.1.2 | Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-30) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver |
| Ekinops | EKINOPS-Pm800fr04 | EKINOPS-Pm800fr04-MIB | pm800fr04MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.120.3.3.144.1.2 | Current Line Optical Module Tx Laser Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the current Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pm801RR | EKINOPS-Pm801RR-MIB | pm801rrMesrclientTxPower | 1.3.6.1.4.1.20044.48.3.2.19 | Line 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm801RR | EKINOPS-Pm801RR-MIB | pm801rrMesrclientRxPower | 1.3.6.1.4.1.20044.48.3.2.20 | Line 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-Pm801RR | EKINOPS-Pm801RR-MIB | pm801rrMesrlineTxPower | 1.3.6.1.4.1.20044.48.3.3.27 | Line 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pm801RR | EKINOPS-Pm801RR-MIB | pm801rrMesrlineRxPower | 1.3.6.1.4.1.20044.48.3.3.28 | Line 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pmapc | EKINOPS-Pmapc-MIB | pmapcMesrpowerLas1 | 1.3.6.1.4.1.20044.42.3.2.16 | Stuff, Wavelength 1 Power :This OID gives the power value of the Sutfing Wavelength 1 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the optical power of the Stuffing Wavelength 1 Laser |
| Ekinops | EKINOPS-Pmapc | EKINOPS-Pmapc-MIB | pmapcMesrpowerLas2 | 1.3.6.1.4.1.20044.42.3.3.24 | Stuff, Wavelength 2 Power :This OID gives the power value of the Sutfing Wavelength 2 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the optical power of the Stuffing Wavelength 2 Laser |
| Ekinops | EKINOPS-PMC1002 | EKINOPS-PMC1002-MIB | pmc1002MesrclientTxPowerMeasPortn | 1.3.6.1.4.1.20044.50.3.2.40.1.2 | Client SFP+ Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-PMC1002 | EKINOPS-PMC1002-MIB | pmc1002MesrclientRxPowerMeasPortn | 1.3.6.1.4.1.20044.50.3.2.48.1.2 | Client SFP+ Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-PMC1002 | EKINOPS-PMC1002-MIB | pmc1002Mesrline1TxPowerMeasPortn | 1.3.6.1.4.1.20044.50.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-PMC1002 | EKINOPS-PMC1002-MIB | pmc1002Mesrline1RxPowerMeasPortn | 1.3.6.1.4.1.20044.50.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pmc1008MP | EKINOPS-Pmc1008MP-MIB | pmc1008mpMesrtxpwrMeasPortn | 1.3.6.1.4.1.20044.47.3.2.40.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-Pmc1008MP | EKINOPS-Pmc1008MP-MIB | pmc1008mpMesrrxpwrMeasPortn | 1.3.6.1.4.1.20044.47.3.2.48.1.2 | Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-Pmc1008MP | EKINOPS-Pmc1008MP-MIB | pmc1008mpMesrxfp1LoTxPowerMeasPortn | 1.3.6.1.4.1.20044.47.3.3.211.1.2 | Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-Pmc1008MP | EKINOPS-Pmc1008MP-MIB | pmc1008mpMesrxfp1LiRxPowerMeasPortn | 1.3.6.1.4.1.20044.47.3.3.212.1.2 | Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-PMC2002 | EKINOPS-PMC2002-MIB | pmc2002MesrclientTxPowerMeasPortn | 1.3.6.1.4.1.20044.52.3.2.40.1.2 | SFP+ Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver |
| Ekinops | EKINOPS-PMC2002 | EKINOPS-PMC2002-MIB | pmc2002MesrclientRxPowerMeasPortn | 1.3.6.1.4.1.20044.52.3.2.48.1.2 | SFP+ Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver |
| Ekinops | EKINOPS-PMC2002 | EKINOPS-PMC2002-MIB | pmc2002Mesrline1TxPowerMeasPortn | 1.3.6.1.4.1.20044.52.3.3.211.1.2 | OTX TLH Tx Power :This OID gives the transmit power value of the OTX TLH plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver |
| Ekinops | EKINOPS-PMC2002 | EKINOPS-PMC2002-MIB | pmc2002Mesrline1RxPowerMeasPortn | 1.3.6.1.4.1.20044.52.3.3.212.1.2 | OTX TLH Rx Power :This OID gives the receive power value of the OTX TLH plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver |
| Ekinops | EKINOPS-Pmcrypto | EKINOPS-Pmcrypto-MIB | pmcryptoMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.96.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmcrypto | EKINOPS-Pmcrypto-MIB | pmcryptoMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.96.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmcrypto | EKINOPS-Pmcrypto-MIB | pmcryptoMesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.96.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pmcrypto | EKINOPS-Pmcrypto-MIB | pmcryptoMesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.96.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pmcryptoe100 | EKINOPS-Pmcryptoe100-MIB | pmcryptoe100MesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.101.3.2.256.1.2 | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pmcryptoe100 | EKINOPS-Pmcryptoe100-MIB | pmcryptoe100MesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.101.3.2.288.1.2 | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pmcryptoe100 | EKINOPS-Pmcryptoe100-MIB | pmcryptoe100MesrlineTxCompositePwrPortn | 1.3.6.1.4.1.20044.101.3.3.160.1.2 | Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pmcryptoe100 | EKINOPS-Pmcryptoe100-MIB | pmcryptoe100MesrlineRxCompositePwrPortn | 1.3.6.1.4.1.20044.101.3.3.192.1.2 | Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Pme1008 | EKINOPS-Pme1008-MIB | pme1008MesrclientTxPwrPortn | 1.3.6.1.4.1.20044.79.3.2.48.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pme1008 | EKINOPS-Pme1008-MIB | pme1008MesrclientRxPwrPortn | 1.3.6.1.4.1.20044.79.3.2.64.1.2 | Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pme1008 | EKINOPS-Pme1008-MIB | pme1008MesrlineRxPwrPortn | 1.3.6.1.4.1.20044.79.3.3.128.1.2 | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pme1008 | EKINOPS-Pme1008-MIB | pme1008MesrlineTxPwrPortn | 1.3.6.1.4.1.20044.79.3.3.80.1.2 | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pmlma10 | EKINOPS-Pmlma10-MIB | pmlma10MesrclientTxPwrPortn | 1.3.6.1.4.1.20044.68.3.2.48.1.2 | Client Optical Module Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmlma10 | EKINOPS-Pmlma10-MIB | pmlma10MesrclientRxPwrPortn | 1.3.6.1.4.1.20044.68.3.2.64.1.2 | Client Optical Module Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmlma10 | EKINOPS-Pmlma10-MIB | pmlma10MesrlineRxPwrPortn | 1.3.6.1.4.1.20044.68.3.3.128.1.2 | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pmlma10 | EKINOPS-Pmlma10-MIB | pmlma10MesrlineTxPwrPortn | 1.3.6.1.4.1.20044.68.3.3.80.1.2 | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-PmMC | EKINOPS-PmMC-MIB | pmmcMesrline1TxPower | 1.3.6.1.4.1.20044.21.3.2.19 | Line 1 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-PmMC | EKINOPS-PmMC-MIB | pmmcMesrline1RxPower | 1.3.6.1.4.1.20044.21.3.2.20 | Line 1 SFP Rx Power :This OID gives the receive power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver |
| Ekinops | EKINOPS-PmMC | EKINOPS-PmMC-MIB | pmmcMesrline2TxPower | 1.3.6.1.4.1.20044.21.3.3.27 | Line 2 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-PmMC | EKINOPS-PmMC-MIB | pmmcMesrline2RxPower | 1.3.6.1.4.1.20044.21.3.3.28 | Line 2 SFP Rx Power :This OID gives the receive power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver |
| Ekinops | EKINOPS-Pmo10010 | EKINOPS-Pmo10010-MIB | pmo10010MesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.76.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmo10010 | EKINOPS-Pmo10010-MIB | pmo10010MesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.76.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmo10010 | EKINOPS-Pmo10010-MIB | pmo10010MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.76.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pmo10010 | EKINOPS-Pmo10010-MIB | pmo10010MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.76.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Pmo1008mp | EKINOPS-Pmo1008mp-MIB | pmo1008mpMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.121.3.2.48.1.2 | Client Optical Module Tx Power :This OID gives the transmit power value of the Client Optical Module, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Optical Module |
| Ekinops | EKINOPS-Pmo1008mp | EKINOPS-Pmo1008mp-MIB | pmo1008mpMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.121.3.2.64.1.2 | Client Optical Module Rx Power :This OID gives the receive power value of the Client Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Optical Module |
| Ekinops | EKINOPS-Pmo1008mp | EKINOPS-Pmo1008mp-MIB | pmo1008mpMesrlineRxPwrPortn | 1.3.6.1.4.1.20044.121.3.3.128.1.2 | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Optical Module |
| Ekinops | EKINOPS-Pmo1008mp | EKINOPS-Pmo1008mp-MIB | pmo1008mpMesrlineTxPwrPortn | 1.3.6.1.4.1.20044.121.3.3.80.1.2 | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Optical Module |
| Ekinops | EKINOPS-Pmo5005 | EKINOPS-Pmo5005-MIB | pmo5005MesrclientTxPwrPortn | 1.3.6.1.4.1.20044.119.3.2.48.1.2 | Client Optical Module Tx Power :This OID gives the transmit power value of the Client Optical Module, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Optical Module |
| Ekinops | EKINOPS-Pmo5005 | EKINOPS-Pmo5005-MIB | pmo5005MesrclientRxPwrPortn | 1.3.6.1.4.1.20044.119.3.2.64.1.2 | Client Optical Module Rx Power :This OID gives the receive power value of the Client Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Optical Module |
| Ekinops | EKINOPS-Pmo5005 | EKINOPS-Pmo5005-MIB | pmo5005MesrlineRxPwrPortn | 1.3.6.1.4.1.20044.119.3.3.128.1.2 | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Optical Module |
| Ekinops | EKINOPS-Pmo5005 | EKINOPS-Pmo5005-MIB | pmo5005MesrlineTxPwrPortn | 1.3.6.1.4.1.20044.119.3.3.80.1.2 | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Optical Module |
| Ekinops | EKINOPS-Pmo6006 | EKINOPS-Pmo6006-MIB | pmo6006MesrclientTxPwrPortn | 1.3.6.1.4.1.20044.70.3.2.48.1.2 | Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmo6006 | EKINOPS-Pmo6006-MIB | pmo6006MesrclientRxPwrPortn | 1.3.6.1.4.1.20044.70.3.2.64.1.2 | Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Pmo6006 | EKINOPS-Pmo6006-MIB | pmo6006MesrlineRxPwrPortn | 1.3.6.1.4.1.20044.70.3.3.128.1.2 | Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Pmo6006 | EKINOPS-Pmo6006-MIB | pmo6006MesrlineTxPwrPortn | 1.3.6.1.4.1.20044.70.3.3.80.1.2 | Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-PmOa | EKINOPS-PmOa-MIB | pmoaMesrclientEdfaTxpwrMeas | 1.3.6.1.4.1.20044.9.3.2.33 | Pre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Pre-Amp |
| Ekinops | EKINOPS-PmOa | EKINOPS-PmOa-MIB | pmoaMesrclientEdfaRxpwrMeas | 1.3.6.1.4.1.20044.9.3.2.34 | Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster |
| Ekinops | EKINOPS-PmOa | EKINOPS-PmOa-MIB | pmoaMesrlineEdfaTxpwrMeas | 1.3.6.1.4.1.20044.9.3.3.41 | Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster |
| Ekinops | EKINOPS-PmOa | EKINOPS-PmOa-MIB | pmoaMesrlineEdfaRxpwrMeas | 1.3.6.1.4.1.20044.9.3.3.42 | Pre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Pre-Amp |
| Ekinops | EKINOPS-PmOab | EKINOPS-PmOab-MIB | pmoabMesrclientEdfaRxpwrMeas | 1.3.6.1.4.1.20044.23.3.2.34 | Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster |
| Ekinops | EKINOPS-PmOab | EKINOPS-PmOab-MIB | pmoabMesrlineEdfaTxpwrMeas | 1.3.6.1.4.1.20044.23.3.3.41 | Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster |
| Ekinops | EKINOPS-PmOabphc | EKINOPS-PmOabphc-MIB | pmoabphcMesrclientEdfaTxpwrMeas | 1.3.6.1.4.1.20044.51.3.2.33 | Pre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Pre-Amp |
| Ekinops | EKINOPS-PmOabphc | EKINOPS-PmOabphc-MIB | pmoabphcMesrclientEdfaRxpwrMeas | 1.3.6.1.4.1.20044.51.3.2.34 | Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster |
| Ekinops | EKINOPS-PmOabphc | EKINOPS-PmOabphc-MIB | pmoabphcMesrlineEdfaTxpwrMeas | 1.3.6.1.4.1.20044.51.3.3.41 | Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster |
| Ekinops | EKINOPS-PmOabphc | EKINOPS-PmOabphc-MIB | pmoabphcMesrlineEdfaRxpwrMeas | 1.3.6.1.4.1.20044.51.3.3.42 | Pre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Pre-Amp |
| Ekinops | EKINOPS-Pmoabphcs | EKINOPS-Pmoabphcs-MIB | pmoabphcsMesrclientMsaOutputPower | 1.3.6.1.4.1.20044.61.3.2.40 | Pre-Amp MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Pre-Amp (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the Pre-Amp |
| Ekinops | EKINOPS-Pmoabphcs | EKINOPS-Pmoabphcs-MIB | pmoabphcsMesrclientMsaInputPower | 1.3.6.1.4.1.20044.61.3.2.39 | Pre-Amp MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Pre-Amp (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the Pre-Amp |
| Ekinops | EKINOPS-Pmoabphcs | EKINOPS-Pmoabphcs-MIB | pmoabphcsMesrlineMsaOutputPower | 1.3.6.1.4.1.20044.61.3.3.56 | Booster MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Booster (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the Booster |
| Ekinops | EKINOPS-Pmoabphcs | EKINOPS-Pmoabphcs-MIB | pmoabphcsMesrlineMsaInputPower | 1.3.6.1.4.1.20044.61.3.3.55 | Booster MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Booster (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the Booster |
| Ekinops | EKINOPS-Pmoac20il | EKINOPS-Pmoac20il-MIB | pmoac20ilMesrclientMsaOutputPower | 1.3.6.1.4.1.20044.114.3.2.40 | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Pmoac20il | EKINOPS-Pmoac20il-MIB | pmoac20ilMesrclientMsaInputPower | 1.3.6.1.4.1.20044.114.3.2.39 | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Pmoac20il | EKINOPS-Pmoac20il-MIB | pmoac20ilMesrlineOscTxPowerPortn | 1.3.6.1.4.1.20044.114.3.3.64.1.2 | OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver |
| Ekinops | EKINOPS-Pmoac20il | EKINOPS-Pmoac20il-MIB | pmoac20ilMesrlineOscRxPowerPortn | 1.3.6.1.4.1.20044.114.3.3.65.1.2 | OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver |
| Ekinops | EKINOPS-PmOail | EKINOPS-PmOail-MIB | pmoailMesrclientEdfaTxpwrMeas | 1.3.6.1.4.1.20044.36.3.2.33 | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL2 |
| Ekinops | EKINOPS-PmOail | EKINOPS-PmOail-MIB | pmoailMesrclientEdfaRxpwrMeas | 1.3.6.1.4.1.20044.36.3.2.34 | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL1 |
| Ekinops | EKINOPS-PmOail | EKINOPS-PmOail-MIB | pmoailMesrlineEdfaTxpwrMeas | 1.3.6.1.4.1.20044.36.3.3.41 | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL1 |
| Ekinops | EKINOPS-PmOail | EKINOPS-PmOail-MIB | pmoailMesrlineEdfaRxpwrMeas | 1.3.6.1.4.1.20044.36.3.3.42 | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL2 |
| Ekinops | EKINOPS-PmOailhc | EKINOPS-PmOailhc-MIB | pmoailhcMesrclientEdfaTxpwrMeas | 1.3.6.1.4.1.20044.55.3.2.33 | IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL2 |
| Ekinops | EKINOPS-PmOailhc | EKINOPS-PmOailhc-MIB | pmoailhcMesrclientEdfaRxpwrMeas | 1.3.6.1.4.1.20044.55.3.2.34 | IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL1 |
| Ekinops | EKINOPS-PmOailhc | EKINOPS-PmOailhc-MIB | pmoailhcMesrlineEdfaTxpwrMeas | 1.3.6.1.4.1.20044.55.3.3.41 | IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL1 |
| Ekinops | EKINOPS-PmOailhc | EKINOPS-PmOailhc-MIB | pmoailhcMesrlineEdfaRxpwrMeas | 1.3.6.1.4.1.20044.55.3.3.42 | IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL2 |
| Ekinops | EKINOPS-Pmoailhcs | EKINOPS-Pmoailhcs-MIB | pmoailhcsMesrclientMsaOutputPower | 1.3.6.1.4.1.20044.62.3.2.40 | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Pmoailhcs | EKINOPS-Pmoailhcs-MIB | pmoailhcsMesrclientMsaInputPower | 1.3.6.1.4.1.20044.62.3.2.39 | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Pmoailhcs | EKINOPS-Pmoailhcs-MIB | pmoailhcsMesrlineMsaOutputPower | 1.3.6.1.4.1.20044.62.3.3.56 | IL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL1 |
| Ekinops | EKINOPS-Pmoailhcs | EKINOPS-Pmoailhcs-MIB | pmoailhcsMesrlineMsaInputPower | 1.3.6.1.4.1.20044.62.3.3.55 | IL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL1 |
| Ekinops | EKINOPS-Pmops | EKINOPS-Pmops-MIB | pmopsMesrcomaTxPower1 | 1.3.6.1.4.1.20044.30.3.2.16 | TX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Transmit optical power on the TX1 of the OPS A |
| Ekinops | EKINOPS-Pmops | EKINOPS-Pmops-MIB | pmopsMesrcomaRxPower1 | 1.3.6.1.4.1.20044.30.3.2.18 | RX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Receive optical power on the RX1 of the OPS A |
| Ekinops | EKINOPS-Pmops2d | EKINOPS-Pmops2d-MIB | pmops2dMesrtxPowerPortn | 1.3.6.1.4.1.20044.71.3.3.16.1.2 | Tx Power :This OID gives the transmit power value of the signal , read on the coupler output (Power=(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Transmit optical power on the TX of the OPS |
| Ekinops | EKINOPS-Pmops2d | EKINOPS-Pmops2d-MIB | pmops2dMesrrxPowerPortn | 1.3.6.1.4.1.20044.71.3.3.24.1.2 | Rx Power :This OID gives the receive power value of the signal , read on the switch input (Power=(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Receive optical power on the RX of the OPS |
| Ekinops | EKINOPS-Pmora14 | EKINOPS-Pmora14-MIB | pmora14Mesrpump1PowerMeas | 1.3.6.1.4.1.20044.72.3.3.65 | Pump 1 Tx Power :This OID gives the Pump1 power value (Power =AV_U16/20) (Unit = mW) <Help> This measure gives the Pump1 Power value |
| Ekinops | EKINOPS-Pmora14 | EKINOPS-Pmora14-MIB | pmora14Mesrpump2PowerMeas | 1.3.6.1.4.1.20044.72.3.3.69 | Pump 2 Tx Power :This OID gives the Pump2 power value (Power =AV_U16/20) (Unit = mW) <Help> This measure gives the Pump2 Power value |
| Ekinops | EKINOPS-PmOSC | EKINOPS-PmOSC-MIB | pmoscMesrportaTxPower | 1.3.6.1.4.1.20044.14.3.2.19 | SFP A Tx Power :This OID gives the transmit power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the port A transceiver |
| Ekinops | EKINOPS-PmOSC | EKINOPS-PmOSC-MIB | pmoscMesrportaRxPower | 1.3.6.1.4.1.20044.14.3.2.20 | SFP A Rx Power :This OID gives the receive power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the port A transceiver |
| Ekinops | EKINOPS-PmOSC | EKINOPS-PmOSC-MIB | pmoscMesrportbTxPower | 1.3.6.1.4.1.20044.14.3.3.27 | SFP B Tx Power :This OID gives the transmit power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the port B transceiver |
| Ekinops | EKINOPS-PmOSC | EKINOPS-PmOSC-MIB | pmoscMesrportbRxPower | 1.3.6.1.4.1.20044.14.3.3.28 | SFP B Rx Power :This OID gives the receive power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the port B transceiver |
| Ekinops | EKINOPS-Pmotdr | EKINOPS-Pmotdr-MIB | pmotdrMesrlineTxPowerPortn | 1.3.6.1.4.1.20044.95.3.3.32.1.2 | Output Power :This OID gives the output power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the output power value of the OTDR SFP |
| Ekinops | EKINOPS-Pmotdr | EKINOPS-Pmotdr-MIB | pmotdrMesrlineRxPowerPortn | 1.3.6.1.4.1.20044.95.3.3.36.1.2 | Input Power :This OID gives the intput power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the intput power value of the OTDR SFP |
| Ekinops | EKINOPS-Rm10001wb | EKINOPS-Rm10001wb-MIB | rm10001wbMesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.86.3.2.256.1.2 | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm10001wb | EKINOPS-Rm10001wb-MIB | rm10001wbMesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.86.3.2.288.1.2 | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm10001wb | EKINOPS-Rm10001wb-MIB | rm10001wbMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.86.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10001wb | EKINOPS-Rm10001wb-MIB | rm10001wbMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.86.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010 | EKINOPS-Rm10010-MIB | rm10010MesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.53.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010 | EKINOPS-Rm10010-MIB | rm10010MesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.53.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010 | EKINOPS-Rm10010-MIB | rm10010MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.53.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010 | EKINOPS-Rm10010-MIB | rm10010MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.53.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010e40 | EKINOPS-Rm10010e40-MIB | rm10010e40MesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.57.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010e40 | EKINOPS-Rm10010e40-MIB | rm10010e40MesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.57.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010e40 | EKINOPS-Rm10010e40-MIB | rm10010e40MesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.57.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010e40 | EKINOPS-Rm10010e40-MIB | rm10010e40MesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.57.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010mp | EKINOPS-Rm10010mp-MIB | rm10010mpMesrclientNetTxPwrPortn | 1.3.6.1.4.1.20044.54.3.2.48.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010mp | EKINOPS-Rm10010mp-MIB | rm10010mpMesrclientNetRxPwrPortn | 1.3.6.1.4.1.20044.54.3.2.64.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010mp | EKINOPS-Rm10010mp-MIB | rm10010mpMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.54.3.3.128.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010mp | EKINOPS-Rm10010mp-MIB | rm10010mpMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.54.3.3.80.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrclientRxPwrPortn | 1.3.6.1.4.1.20044.92.3.2.112.1.2 | Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.92.3.2.256.1.2 | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.92.3.2.288.1.2 | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrclientTxPwrPortn | 1.3.6.1.4.1.20044.92.3.2.80.1.2 | Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.92.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm10010wb | EKINOPS-Rm10010wb-MIB | rm10010wbMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.92.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm200frs02wb | EKINOPS-Rm200frs02wb-MIB | rm200frs02wbMesrclientTxCompositePwrPortn | 1.3.6.1.4.1.20044.105.3.2.256.1.2 | Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm200frs02wb | EKINOPS-Rm200frs02wb-MIB | rm200frs02wbMesrclientRxCompositePwrPortn | 1.3.6.1.4.1.20044.105.3.2.288.1.2 | Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only) |
| Ekinops | EKINOPS-Rm200frs02wb | EKINOPS-Rm200frs02wb-MIB | rm200frs02wbMesrlineNetTxLaserOutputPwrPortn | 1.3.6.1.4.1.20044.105.3.3.144.1.2 | Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver |
| Ekinops | EKINOPS-Rm200frs02wb | EKINOPS-Rm200frs02wb-MIB | rm200frs02wbMesrlineNetRxInputPwrPortn | 1.3.6.1.4.1.20044.105.3.3.156.1.2 | Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver |
| Ekinops | EKINOPS-Rmoac17ilwb | EKINOPS-Rmoac17ilwb-MIB | rmoac17ilwbMesrclientMsaOutputPower | 1.3.6.1.4.1.20044.110.3.2.40 | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Rmoac17ilwb | EKINOPS-Rmoac17ilwb-MIB | rmoac17ilwbMesrclientMsaInputPower | 1.3.6.1.4.1.20044.110.3.2.39 | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Rmoac17ilwb | EKINOPS-Rmoac17ilwb-MIB | rmoac17ilwbMesrlineOscTxPowerPortn | 1.3.6.1.4.1.20044.110.3.3.64.1.2 | OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver |
| Ekinops | EKINOPS-Rmoac17ilwb | EKINOPS-Rmoac17ilwb-MIB | rmoac17ilwbMesrlineOscRxPowerPortn | 1.3.6.1.4.1.20044.110.3.3.65.1.2 | OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver |
| Ekinops | EKINOPS-Rmoac17wb | EKINOPS-Rmoac17wb-MIB | rmoac17wbMesrclientMsaOutputPower | 1.3.6.1.4.1.20044.102.3.2.40 | IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Rmoac17wb | EKINOPS-Rmoac17wb-MIB | rmoac17wbMesrclientMsaInputPower | 1.3.6.1.4.1.20044.102.3.2.39 | IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2 |
| Ekinops | EKINOPS-Rmoac17wb | EKINOPS-Rmoac17wb-MIB | rmoac17wbMesrlineOscTxPowerPortn | 1.3.6.1.4.1.20044.102.3.3.64.1.2 | OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver |
| Ekinops | EKINOPS-Rmoac17wb | EKINOPS-Rmoac17wb-MIB | rmoac17wbMesrlineOscRxPowerPortn | 1.3.6.1.4.1.20044.102.3.3.65.1.2 | OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver |
| Electroline Equipment Inc. | ELECTROLINE-DHT-STATUS | ELECTROLINE-DHT-STATUS-MIB | dlmRxPowerLevel | 1.3.6.1.4.1.5802.1.3.1.2.3.6.3 | The received power level at the DLM input. It's the modem RX power level added to the RF attenuator pad value. |
| Electroline Equipment Inc. | ELECTROLINE-DHT-STATUS | ELECTROLINE-DHT-STATUS-MIB | dlmTxPowerLevel | 1.3.6.1.4.1.5802.1.3.1.2.3.6.4 | The transmit power level at the DLM output. It's the modem TX power level minus the RF attenuator pad value. |
| Eltex | ELTEX-LTP8X | ELTEX-LTP8X | ltp8xPONChannelTxPower | 1.3.6.1.4.1.35265.1.22.2.1.1.9 | in dBm * 1000 |
| Eltex | ELTEX-LTP8X | ELTEX-LTP8X | ltp8xONTStateTxPower | 1.3.6.1.4.1.35265.1.22.3.1.1.13 | in dBm * 1000 (only for NTP-2C) |
| Eltex | ELTEX-LTP8X | ELTEX-LTP8X | ltp8xONTStateRxPower | 1.3.6.1.4.1.35265.1.22.3.1.1.14 | in dBm * 1000 (only for NTP-2C) |
| Eltex | ELTEX-PP4 | ELTEX-PP4 | sfpInfoRXPower | 1.3.6.1.4.1.35265.1.13.18.1.5 | Measured in uW. |
| Eltex | ELTEX-PP4 | ELTEX-PP4 | sfpInfoTXPower | 1.3.6.1.4.1.35265.1.13.18.1.6 | Measured in uW. |
| Dell (Force10) | F10-M-SERIES-CHASSIS | F10-M-SERIES-CHASSIS-MIB | chSysPortXfpRecvPower | 1.3.6.1.4.1.6027.3.19.1.2.4.1.6 | The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-M-SERIES-CHASSIS | F10-M-SERIES-CHASSIS-MIB | chSysPortXfpTxPower | 1.3.6.1.4.1.6027.3.19.1.2.4.1.8 | The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-S-SERIES-CHASSIS | F10-S-SERIES-CHASSIS-MIB | chSysIfXfpTxPower | 1.3.6.1.4.1.6027.3.10.1.2.11.1.7 | The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-S-SERIES-CHASSIS | F10-S-SERIES-CHASSIS-MIB | chSysPortXfpRecvPower | 1.3.6.1.4.1.6027.3.10.1.2.5.1.6 | The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-S-SERIES-CHASSIS | F10-S-SERIES-CHASSIS-MIB | chSysPortXfpTxPower | 1.3.6.1.4.1.6027.3.10.1.2.5.1.8 | The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-Z-SERIES-CHASSIS | F10-Z-SERIES-CHASSIS-MIB | chSysPortXfpRxPower | 1.3.6.1.4.1.6027.3.25.1.2.5.1.6 | The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface. |
| Dell (Force10) | F10-Z-SERIES-CHASSIS | F10-Z-SERIES-CHASSIS-MIB | chSysPortXfpTxPower | 1.3.6.1.4.1.6027.3.25.1.2.5.1.8 | The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. |
| Brocade | FA-EXT | FA-EXT-MIB | swSfpRxPower | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4 | This object identifies the Rx power consumption of SFP. |
| Brocade | FA-EXT | FA-EXT-MIB | swSfpTxPower | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5 | This object identifies the Tx power consumption of SFP. |
| FS.com (Fiberstore) | FIBERSTORE | FIBERSTORE-MIB | transpowerCurrent | 1.3.6.1.4.1.52642.1.37.1.10.5.1.5 | Transceiver currently transmit power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber. |
| FS.com (Fiberstore) | FIBERSTORE | FIBERSTORE-MIB | receivepowerCurrent | 1.3.6.1.4.1.52642.1.37.1.10.6.1.5 | Transceiver currently receive power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber. |
| Fibrolan | FIBROLAN-SFP | FIBROLAN-SFP-MIB | flSfpRxPower | 1.3.6.1.4.1.4467.1000.50.1.2.1.1 | Received average optical power in [uW] |
| Fibrolan | FIBROLAN-SFP | FIBROLAN-SFP-MIB | flSfpTxPower | 1.3.6.1.4.1.4467.1000.50.1.2.1.2 | Transmitted average optical power in [uW] |
| Brocade (Foundry Networks) | FOUNDRY-SN-SWITCH-GROUP | FOUNDRY-SN-SWITCH-GROUP-MIB | snIfOpticalLaneMonitoringTxPower | 1.3.6.1.4.1.1991.1.1.3.3.10.1.3 | This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. |
| Brocade (Foundry Networks) | FOUNDRY-SN-SWITCH-GROUP | FOUNDRY-SN-SWITCH-GROUP-MIB | snIfOpticalLaneMonitoringRxPower | 1.3.6.1.4.1.1991.1.1.3.3.10.1.4 | This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. |
| FS.com (Fiberstore) | FS-AC-MGMT | FS-AC-MGMT-MIB | fsApCurTxPower | 1.3.6.1.4.1.52642.1.1.10.2.56.2.1.2.1.17 | Current tx power, mw. |
| FS.com (Fiberstore) | FS-AC-MGMT | FS-AC-MGMT-MIB | fsApTxPower | 1.3.6.1.4.1.52642.1.1.10.2.56.2.1.2.1.3 | Tx power, 1%. |
| FS.com (Fiberstore) | FS-FIBER | FS-FIBER-MIB | fsFiberRXpowerInteger | 1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.76 | The integer of Rx power of the Fiber module insered into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Rx power value is -10000(means that the value is invalid). Added by Observium Developers. |
| FS.com (Fiberstore) | FS-FIBER | FS-FIBER-MIB | fsFiberChannel1RXpowerInteger | 1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.77 | The integer part of Rx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -10000(means the value is invalid). Added by Observium Developers. |
| FS.com (Fiberstore) | FS-FIBER | FS-FIBER-MIB | fsFiberTXpowerInteger | 1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.81 | The integer part of Tx power of the Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Tx power value is -10000(means that the value is invalid). Added by Observium Developers. |
| FS.com (Fiberstore) | FS-FIBER | FS-FIBER-MIB | fsFiberChannel1TXpowerInteger | 1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.82 | The integer part of Tx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -10000(means the value is invalid). Added by Observium Developers. |
| FS.com (Fiberstore) | FS-NMS-IF | FS-NMS-IF-MIB | txPower3 | 1.3.6.1.4.1.52642.9.63.1.7.1.11 | The tx 3 power of optical module. The unit is 1DBm. |
| FS.com (Fiberstore) | FS-NMS-IF | FS-NMS-IF-MIB | rxPower3 | 1.3.6.1.4.1.52642.9.63.1.7.1.12 | The rx 3 power of optical module. The unit is 1DBm. |
| FS.com (Fiberstore) | FS-NMS-OPTICAL-PORT | FS-NMS-OPTICAL-PORT-MIB | opIfRxPowerCurr | 1.3.6.1.4.1.52642.9.183.1.1.5 | A unique value for each optical interface, that means optical current receive power value. |
| FS.com (Fiberstore) | FS-NMS-OPTICAL-PORT | FS-NMS-OPTICAL-PORT-MIB | opIfTxPowerCurr | 1.3.6.1.4.1.52642.9.183.1.1.8 | A unique value for each optical interface, that means optical current sending power value. |
| FS.com | FS-SWITCH | FS-SWITCH-MIB | transpowerCurrent | 1.3.6.1.4.1.27975.37.1.10.5.1.5 | Transceiver currently transmit power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber. |
| FS.com | FS-SWITCH | FS-SWITCH-MIB | receivepowerCurrent | 1.3.6.1.4.1.27975.37.1.10.6.1.5 | Transceiver currently receive power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber. |
| ADVA Optical Networking | FspR7 | FspR7-MIB | opticalIfDiagInputPower | 1.3.6.1.4.1.2544.1.11.2.4.3.5.1.3 | The optical input power of a transmitter in dBm, measured in the range of -x to +y dBm (TBD). It is only valid when there is no loss of signal at the input, in which case a value of -65535 is returned. A value of -65535 also indicates that OIP is not available. When out of range, -65534 indicates that the OIP is outside the maximum value and -65533 for outside the minimum value. |
| Fujitsu Limited | FSS-OPTICAL-CHANNEL-INTERFACE | FSS-OPTICAL-CHANNEL-INTERFACE | ochTx-target-power | 1.3.6.1.4.1.211.1.24.12.700.200.1.1.7 | Transmit output power setting. |
| Microsens | G6-SFP | G6-SFP-MIB | informationTxPower | 1.3.6.1.4.1.3181.10.6.1.34.100.1.18 | Indicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown. |
| Microsens | G6-SFP | G6-SFP-MIB | informationRxPower | 1.3.6.1.4.1.3181.10.6.1.34.100.1.19 | Indicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown. |
| Gainspeed, Inc. | GAINSPEED-ENVMON | GAINSPEED-ENVMON-MIB | gsemUplinkOpticsRxPower | 1.3.6.1.4.1.44886.10.10.1.4.1.1.2 | optics receive-power value of one uplink port. |
| Gainspeed, Inc. | GAINSPEED-ENVMON | GAINSPEED-ENVMON-MIB | gsemUplinkOpticsTxPower | 1.3.6.1.4.1.44886.10.10.1.4.1.1.3 | optics transmit-power value of one uplink port. |
| Trango Networks, LLC | GIGA-PLUS | GIGA-PLUS-MIB | rfPower | 1.3.6.1.4.1.5454.1.80.3.4.1 | Set/Display TX power. SNMPc does not support setting and displaying float value. |
| GCOM / Greentech | GPON | GPON-MIB | ponRXPower | 1.3.6.1.4.1.13464.1.11.3.1.1.24 | unit: dBm |
| GCOM / Greentech | GPON | GPON-MIB | ponTXPower | 1.3.6.1.4.1.13464.1.11.3.1.1.27 | unit: dBm |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDM | GUD-CCDM-MIB | ioCardFiberTxPower | 1.3.6.1.4.1.32828.3.257.10.2.3.1005.1.3 | TX power for each fiber io card port. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDM | GUD-CCDM-MIB | ioCardFiberRxPower | 1.3.6.1.4.1.32828.3.257.10.2.3.1005.1.4 | RX power for each fiber io card port. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCON | GUD-CCDMCON-MIB | sfpTxPower | 1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.20 | SFP TX power [uW] of the device. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCON | GUD-CCDMCON-MIB | sfpTxPower2 | 1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.22 | SFP TX power [uW] of the second transmission line of the device. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCON | GUD-CCDMCON-MIB | sfpRxPower | 1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.23 | SFP RX power [uW] of the device. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCON | GUD-CCDMCON-MIB | sfpRxPower2 | 1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.25 | SFP RX power [uW] of the second transmission line of the device. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCPU | GUD-CCDMCPU-MIB | sfpTxPower | 1.3.6.1.4.1.32828.3.257.10.1.2.2.3.1000.1.21 | SFP TX power [uW] of the device. |
| Guntermann & Drunck GmbH Systementwicklung | GUD-CCDMCPU | GUD-CCDMCPU-MIB | sfpRxPower | 1.3.6.1.4.1.32828.3.257.10.1.2.2.3.1000.1.22 | SFP RX power [uW] of the device. |
| Huawei | H3C-TRANSCEIVER-INFO | H3C-TRANSCEIVER-INFO-MIB | h3cTransceiverCurRXPower | 1.3.6.1.4.1.2011.10.2.70.1.1.1.12 | Indicating the current received power . The unit is in hundredths of dBM. |
| Huawei | H3C-TRANSCEIVER-INFO | H3C-TRANSCEIVER-INFO-MIB | h3cTransceiverCurTXPower | 1.3.6.1.4.1.2011.10.2.70.1.1.1.9 | Indicating the current transmitted power . The unit is in hundredths of dBM. |
| H3C | HH3C-3GMODEM | HH3C-3GMODEM-MIB | hh3cLteTxPower | 1.3.6.1.4.1.25506.2.98.1.5.1.1.4 | Transmit power, 0x8000 means invalid. |
| H3C | HH3C-TRANSCEIVER-INFO | HH3C-TRANSCEIVER-INFO-MIB | hh3cTransceiverChannelCurTXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.2 | Indicating the current transmission power. The unit is in hundredths of dBM. |
| H3C | HH3C-TRANSCEIVER-INFO | HH3C-TRANSCEIVER-INFO-MIB | hh3cTransceiverChannelCurRXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.3 | Indicating the current received power. The unit is in hundredths of dBM. |
| Hirschmann | HIRSCHMANN-BAT-F-SINGLE | HIRSCHMANN-BAT-F-SINGLE-MIB | hmStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.248.32.16.10.1.51.11.1.14 | No description published. |
| Hirschmann | HIRSCHMANN-BAT-F-SINGLE | HIRSCHMANN-BAT-F-SINGLE-MIB | hmStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.248.32.16.10.1.51.11.1.15 | No description published. |
| Hirschmann | HIRSCHMANN-BAT-RAIL-SINGLE | HIRSCHMANN-BAT-RAIL-SINGLE-MIB | hmStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.248.32.16.11.1.51.11.1.14 | No description published. |
| Hirschmann | HIRSCHMANN-BAT-RAIL-SINGLE | HIRSCHMANN-BAT-RAIL-SINGLE-MIB | hmStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.248.32.16.11.1.51.11.1.15 | No description published. |
| Hirschmann | HIRSCHMANN-BAT300RAIL | HIRSCHMANN-BAT300RAIL-MIB | hmStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.248.32.16.40.1.51.11.1.14 | No description published. |
| Hirschmann | HIRSCHMANN-BAT300RAIL | HIRSCHMANN-BAT300RAIL-MIB | hmStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.248.32.16.40.1.51.11.1.15 | No description published. |
| Hirschmann | HIRSCHMANN-BAT54CLIENT | HIRSCHMANN-BAT54CLIENT-MIB | hmStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.248.32.16.9.1.51.11.1.14 | No description published. |
| Hirschmann | HIRSCHMANN-BAT54CLIENT | HIRSCHMANN-BAT54CLIENT-MIB | hmStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.248.32.16.9.1.51.11.1.15 | No description published. |
| Hirschmann | HIRSCHMANN-BAT54RAIL | HIRSCHMANN-BAT54RAIL-MIB | hmStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.248.32.16.8.1.51.11.1.14 | No description published. |
| Hirschmann | HIRSCHMANN-BAT54RAIL | HIRSCHMANN-BAT54RAIL-MIB | hmStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.248.32.16.8.1.51.11.1.15 | No description published. |
| Hirschmann | HM2-DEVMGMT | HM2-DEVMGMT-MIB | hm2SfpCurrentTxPowerdBm | 1.3.6.1.4.1.248.11.10.1.7.2.1.5 | The SFP's internally measured Tx Power in units of dBm. (ASCII representation of a floating point number). - if not supported. |
| Hirschmann | HM2-DEVMGMT | HM2-DEVMGMT-MIB | hm2SfpCurrentRxPowerdBm | 1.3.6.1.4.1.248.11.10.1.7.2.1.6 | The SFP's internally measured Rx Power in units of dBm. (ASCII representation of a floating point number). - if not supported. |
| Hirschmann | HMIT-SW-PORTMGR-DDMI | HMIT-SW-PORTMGR-DDMI-MIB | portDDMITxPower | 1.3.6.1.4.1.248.100.1.6.3.1.13.6.1.31 | The tx power measured by the transceiver itself. |
| Hirschmann | HMPRIV-MGMT-SNMP | HMPRIV-MGMT-SNMP-MIB | hmSfpTxPower | 1.3.6.1.4.1.248.14.1.1.13.1.13 | The SFP's internally measured Tx Power in units of milliWatts. (ASCII representation of floating point number). |
| Hirschmann | HMPRIV-MGMT-SNMP | HMPRIV-MGMT-SNMP-MIB | hmSfpRxPower | 1.3.6.1.4.1.248.14.1.1.13.1.14 | The SFP's internally measured Rx Power in units of milliWatts. (ASCII representation of floating point number). |
| HP | HP-ICF-TRANSCEIVER | HP-ICF-TRANSCEIVER-MIB | hpicfXcvrTxPower | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14 | This is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. |
| HP | HPN-ICF-TRANSCEIVER-INFO | HPN-ICF-TRANSCEIVER-INFO-MIB | hpnicfTransceiverChannelCurTXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.2 | Indicating the current transmission power. The unit is in hundredths of dBM. |
| HP | HPN-ICF-TRANSCEIVER-INFO | HPN-ICF-TRANSCEIVER-INFO-MIB | hpnicfTransceiverChannelCurRXPower | 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.3 | Indicating the current received power. The unit is in hundredths of dBM. |
| Huawei | HUAWEI-ENTITY-EXTENT | HUAWEI-ENTITY-EXTENT-MIB | hwEntityOpticalLaneRxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.32 | The receive power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 114,32,-90,-228) |
| Huawei | HUAWEI-ENTITY-EXTENT | HUAWEI-ENTITY-EXTENT-MIB | hwEntityOpticalLaneTxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.33 | The transmit power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 94,-39,33,-58) |
| Huawei | HUAWEI-ENTITY-EXTENT | HUAWEI-ENTITY-EXTENT-MIB | hwEntityOpticalRxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.8 | The receive power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| Huawei | HUAWEI-ENTITY-EXTENT | HUAWEI-ENTITY-EXTENT-MIB | hwEntityOpticalTxPower | 1.3.6.1.4.1.2011.5.25.31.1.1.3.1.9 | The transmit power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times |
| Huawei | HUAWEI-ENVIRONMENT | HUAWEI-ENVIRONMENT-MIB | hwOTOpticalOutputPowerValue | 1.3.6.1.4.1.2011.6.1.1.7.1.21 | This is the power of the only channel for the single-channel optical transmitter. This is the power of channel 0 for the dual-channel optical transmitter. Its unit is 0.01dbm. invalid: 0x7fffffff. |
| Huawei | HUAWEI-ENVIRONMENT | HUAWEI-ENVIRONMENT-MIB | hwOROpticalCH1PowerValue | 1.3.6.1.4.1.2011.6.1.1.7.1.32 | This is the power of channel 1 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff. |
| Huawei | HUAWEI-ENVIRONMENT | HUAWEI-ENVIRONMENT-MIB | hwOTOpticalOutputCH1PowerValue | 1.3.6.1.4.1.2011.6.1.1.7.1.39 | This is the power of channel 1 for the dual-channel optical transmitter. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff. |
| Huawei | HUAWEI-ETHERNET-OPTICMODULE | HUAWEI-ETHERNET-OPTICMODULE-MIB | hwOpticsTxPower | 1.3.6.1.4.1.2011.5.14.6.4.1.4 | Transmitted power. Invalid value: 2147483647, an invalid value is returned if the optical module is unavailable or is not supported. Unit: 0.000001dBm |
| Huawei | HUAWEI-ETHERNET-OPTICMODULE | HUAWEI-ETHERNET-OPTICMODULE-MIB | hwOpticsRxPower | 1.3.6.1.4.1.2011.5.14.6.4.1.5 | Received power. Invalid value: 2147483647, an invalid value is returned if the optical module is unavailable or is not supported. Unit: 0.000001dBm |
| Huawei | HUAWEI-GONU | HUAWEI-GONU-MIB | hwGonuTxPower | 1.3.6.1.4.1.2011.5.104.1.1.1.1.8 | The MDU TX power. Unit: 1/100 dBm |
| Huawei | HUAWEI-GONU | HUAWEI-GONU-MIB | hwGonuRxPower | 1.3.6.1.4.1.2011.5.104.1.1.1.1.9 | The MDU RX power. Unit: 1/100 dBm |
| Huawei | HUAWEI-GONU | HUAWEI-GONU-MIB | hwGonuOltPonTxPower | 1.3.6.1.4.1.2011.5.104.1.9.1.1.2 | OLT PON TX power. Unit: 1/100 dBm |
| Huawei | HUAWEI-GPON | HUAWEI-GPON-MIB | hwGponOntCatvTxPower | 1.3.6.1.4.1.2011.5.100.1.1.1.25.1.7 | This object indicates the Tx power of ONT CATV port. Unit: 0.001dBmV Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected |
| Huawei | HUAWEI-GPON | HUAWEI-GPON-MIB | hwGponOpticsTxPower | 1.3.6.1.4.1.2011.5.100.1.1.1.51.1.4 | Optics send power,units of 0.01dBm. |
| Huawei | HUAWEI-GPON | HUAWEI-GPON-MIB | hwGponOntOpticsOltRxOntPower | 1.3.6.1.4.1.2011.5.100.1.1.1.53.1.6 | The ONT optical power received on the OLT, unit dBm. The relationship between the actual value and the value get from this leaf node is as follows, Actual value = ((Node value - 10000) / 100) |
| Huawei | HUAWEI-XPON | HUAWEI-XPON-MIB | hwEponOntOpticalDdmOltRxOntPower | 1.3.6.1.4.1.2011.6.128.1.1.2.104.1.1 | The ONT optical power received on the OLT, unit dBm. The relationship between the actual value and the value get from this leaf node is as follows, Actual value = ((Node value - 10000) / 100) |
| Icotera A/S | ICOTERA-I6400-SERIES | ICOTERA-I6400-SERIES | transceiverDdmTxPower | 1.3.6.1.4.1.29865.11.3.1.3.2 | Measured TX output power. Represented in increments of 1/10000 mW. |
| Icotera A/S | ICOTERA-I6400-SERIES | ICOTERA-I6400-SERIES | transceiverDdmRxPower | 1.3.6.1.4.1.29865.11.3.1.3.3 | Measured RX received optical power. Represented in increments of 1/10000 mW. |
| Zyxel | IES5206 | IES5206-MIB | transceiverPerOntRxPower | 1.3.6.1.4.1.890.1.5.13.13.31.14.4.1.2 | Transceiver high alarm threshold. The unit for RX power is dbm The value neg inf represents negative infinit(0mW) The value N/A represents not applicable. |
| Zyxel | IES5206 | IES5206-MIB | geDdmiTxPowerdBm | 1.3.6.1.4.1.890.1.5.13.13.4.4.1.18 | Measured TX output power in 10^(-4) dBm. |
| IPI | IPI-CMM-CHASSIS | IPI-CMM-CHASSIS-MIB | cmmTransTxPower | 1.3.6.1.4.1.36673.100.1.2.3.1.17 | Measured TX output power in Channel of transceiver. '-100000' value represents no power. '-100001' indicates unavailable. '-100002' indicates not-applicable. |
| IPI | IPI-CMM-CHASSIS | IPI-CMM-CHASSIS-MIB | cmmTransRxPower | 1.3.6.1.4.1.36673.100.1.2.3.1.22 | Measured RX input power in Channel of transceiver '-100000' value represents no power in the transceiver. '-100001' indicates unavailable. '-100002' indicates not-applicable. |
| Iskratel, Ltd. | ISKRATEL-MSAN | ISKRATEL-MSAN-MIB | msanSfpDiagnosticsTxPowerCurrent | 1.3.6.1.4.1.1332.1.1.5.3.32.3.1.12 | Current SFP module transmitted optical output power value in [mW]. If diagnostic is not supported for SFP module then current transmitted optical output power is set on not supported value(-1). |
| Iskratel, Ltd. | ISKRATEL-MSAN | ISKRATEL-MSAN-MIB | msanSfpDiagnosticsRxPowerCurrent | 1.3.6.1.4.1.1332.1.1.5.3.32.3.1.15 | Current SFP module received optical input power value in [mW]. If diagnostic is not supported for SFP module then current received optical input power is set on not supported value(-1). |
| Korenix | Jetnet4510 | Jetnet4510 | portSfpDdmRxPowerRange | 1.3.6.1.4.1.24062.2.2.3.3.2.2.1.10 | The range of SFP Receiveed Power of port. |
| Korenix | Jetnet4510 | Jetnet4510 | portSfpDdmTxPowerCurrent | 1.3.6.1.4.1.24062.2.2.3.3.2.2.1.7 | The current SFP Transmitted Power of port. |
| Korenix | Jetnet4510 | Jetnet4510 | portSfpDdmTxPowerRange | 1.3.6.1.4.1.24062.2.2.3.3.2.2.1.8 | The range of SFP Transmitted Power of port. |
| Korenix | Jetnet4510 | Jetnet4510 | portSfpDdmRxPowerCurrent | 1.3.6.1.4.1.24062.2.2.3.3.2.2.1.9 | The current SFP Receiveed Power of port. |
| Korenix | Jetnet5010G | Jetnet5010G | portSfpDdmRxPowerRange | 1.3.6.1.4.1.24062.2.2.1.3.2.2.1.10 | The range of SFP Receiveed Power of port. |
| Korenix | Jetnet5010G | Jetnet5010G | portSfpDdmTxPowerCurrent | 1.3.6.1.4.1.24062.2.2.1.3.2.2.1.7 | The current SFP Transmitted Power of port. |
| Korenix | Jetnet5010G | Jetnet5010G | portSfpDdmTxPowerRange | 1.3.6.1.4.1.24062.2.2.1.3.2.2.1.8 | The range of SFP Transmitted Power of port. |
| Korenix | Jetnet5010G | Jetnet5010G | portSfpDdmRxPowerCurrent | 1.3.6.1.4.1.24062.2.2.1.3.2.2.1.9 | The current SFP Receiveed Power of port. |
| Korenix | Jetnet5310G | Jetnet5310G | portSfpDdmRxPowerRange | 1.3.6.1.4.1.24062.2.3.9.3.2.2.1.10 | The range of SFP Receiveed Power of port. |
| Korenix | Jetnet5310G | Jetnet5310G | portSfpDdmTxPowerCurrent | 1.3.6.1.4.1.24062.2.3.9.3.2.2.1.7 | The current SFP Transmitted Power of port. |
| Korenix | Jetnet5310G | Jetnet5310G | portSfpDdmTxPowerRange | 1.3.6.1.4.1.24062.2.3.9.3.2.2.1.8 | The range of SFP Transmitted Power of port. |
| Korenix | Jetnet5310G | Jetnet5310G | portSfpDdmRxPowerCurrent | 1.3.6.1.4.1.24062.2.3.9.3.2.2.1.9 | The current SFP Receiveed Power of port. |
| Juniper | JUNIPER-DOM | JUNIPER-DOM-MIB | jnxDomCurrentRxLaserPower | 1.3.6.1.4.1.2636.3.60.1.1.1.1.5 | Receiver laser power. |
| Juniper | JUNIPER-DOM | JUNIPER-DOM-MIB | jnxDomCurrentTxLaserOutputPower | 1.3.6.1.4.1.2636.3.60.1.1.1.1.7 | Transmitter laser output power. |
| Juniper | JUNIPER-DOM | JUNIPER-DOM-MIB | jnxDomCurrentLaneRxLaserPower | 1.3.6.1.4.1.2636.3.60.1.2.1.1.6 | Receiver laser power on a particular Lane of a SFF physcial interface. |
| Juniper | JUNIPER-DOM | JUNIPER-DOM-MIB | jnxDomCurrentLaneTxLaserOutputPower | 1.3.6.1.4.1.2636.3.60.1.2.1.1.8 | Transmitter laser power on a particular Lane of a SFF physcial interface. |
| Katron Technologies Inc. | KGD-802-B_MIB | KGD-802-B_MIB | TX_Power | 1.3.6.1.4.1.867.65.1.1.1.10 | Measured TX output power(uW). dBm = -30 dBm + log10( N ) x 10 |
| Deltanet | LAMBDATRAIL | LAMBDATRAIL-MIB | portClientTxPower | 1.3.6.1.4.1.35616.2.1.1.12.1.15 | unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available |
| Deltanet | LAMBDATRAIL | LAMBDATRAIL-MIB | portClientRxPower | 1.3.6.1.4.1.35616.2.1.1.12.1.16 | unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available |
| Deltanet | LAMBDATRAIL | LAMBDATRAIL-MIB | portLineTxPower | 1.3.6.1.4.1.35616.2.1.1.12.1.8 | unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available |
| Deltanet | LAMBDATRAIL | LAMBDATRAIL-MIB | portLineRxPower | 1.3.6.1.4.1.35616.2.1.1.12.1.9 | unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sMgmtSfpTxPower | 1.3.6.1.4.1.35616.5.1.26.1.13 | The SFP transmit power of the port. If the SFP is removed, the value is -1. |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sMgmtSfpRxPower | 1.3.6.1.4.1.35616.5.1.26.1.14 | The SFP receive power of the port. If the SFP is removed, the value is -1. |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sLineTxPower | 1.3.6.1.4.1.35616.5.3.1.1.13 | The line SFP transmit power of the port. If the line SFP is not plugged in, the object should contain the value of -1. |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sLineRxPower | 1.3.6.1.4.1.35616.5.3.1.1.14 | The line SFP receive power of the port. If the line SFP is not plugged in, the object should contain the value of -1. |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sClientTxPower | 1.3.6.1.4.1.35616.5.3.1.1.26 | The client SFP transmit power of the port. If the client SFP is not plugged in, the object should contain the value of -1. |
| Deltanet | Lambdatrail2s | Lambdatrail2s-MIB | lt2sClientRxPower | 1.3.6.1.4.1.35616.5.3.1.1.27 | The client SFP receive power of the port. If the client SFP is not plugged in, the object should contain the value of -1. |
| LANCOM Systems | LCOS | LCOS-MIB | lcsStatusEthernetPortsSfpPortsEntryTxPower | 1.3.6.1.4.1.2356.11.1.51.11.1.14 | No description published. |
| LANCOM Systems | LCOS | LCOS-MIB | lcsStatusEthernetPortsSfpPortsEntryRxPower | 1.3.6.1.4.1.2356.11.1.51.11.1.15 | No description published. |
| LuxN, Inc. | LUXN | LUXN-MIB | dmmPortRxPower | 1.3.6.1.4.1.4253.1.28.3.1.10 | Receive power reported by port SFP. |
| LuxN, Inc. | LUXN | LUXN-MIB | oscPortRxPower | 1.3.6.1.4.1.4253.1.31.3.1.7 | Receive power reported by port SFP. |
| Cisco | ME1200-DDMI | ME1200-DDMI-MIB | me1200DdmiStatusInterfaceA2CurrentTxPower | 1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1018 | Current Tx power in mV. |
| Cisco | ME1200-DDMI | ME1200-DDMI-MIB | me1200DdmiStatusInterfaceA2CurrentRxPower | 1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1023 | Current Rx power in mV. |
| Microsens | MICROSENS-CWDM8 | MICROSENS-CWDM8-MIB | lineModuleTransmittedPower | 1.3.6.1.4.1.3181.6.4.4.1.18 | This entry describes the transmitter optical output power in micro watt. |
| Microsens | MICROSENS-CWDM8 | MICROSENS-CWDM8-MIB | lineModuleReceivedPower | 1.3.6.1.4.1.3181.6.4.4.1.19 | This entry describes the transmitter optical received power in micro watt. |
| Microsens | MICROSENS-CWDM8 | MICROSENS-CWDM8-MIB | lineIfWestLinkRcvPower | 1.3.6.1.4.1.3181.6.4.6.1.8 | This entry describes the west-link receive power of the interface module in micro watts. |
| Microsens | MICROSENS-CWDM8 | MICROSENS-CWDM8-MIB | lineIfEastLinkRcvPower | 1.3.6.1.4.1.3181.6.4.6.1.9 | This entry describes the east-link receive power of the interface module in micro watts. |
| Mimosa Networks | MIMOSA-NETWORKS-BFIVE | MIMOSA-NETWORKS-BFIVE-MIB | mimosaTxPower | 1.3.6.1.4.1.43356.2.1.2.6.1.1.2 | Specifies the transmit power of the given RF chain. A value of -8 means this particular TxChain is not a valid entry. |
| Mimosa Networks | MIMOSA-NETWORKS-BFIVE | MIMOSA-NETWORKS-BFIVE-MIB | mimosaRxPower | 1.3.6.1.4.1.43356.2.1.2.6.1.1.3 | Specifies the receive power of the given RF chain. A value of -100 means this particular RxChain is not a valid entry (SNR must be -100). |
| Mimosa Networks | MIMOSA-NETWORKS-BFIVE | MIMOSA-NETWORKS-BFIVE-MIB | mimosaChannelTxPower | 1.3.6.1.4.1.43356.2.1.2.6.3.1.4 | Specifies the transmit power level on the channel. If Channel Width is set to 1xN MHz, Channel 2 is not be used. In Frequency Diversity mode, Power 1 and Power 2 represent transmit power on the local and remote sides, respectively. |
| Mimosa Networks | MIMOSA-NETWORKS-BFIVE | MIMOSA-NETWORKS-BFIVE-MIB | mimosaTotalTxPower | 1.3.6.1.4.1.43356.2.1.2.6.5 | The total transmit power for all the channels on the Mimosa device. |
| Mimosa Networks | MIMOSA-NETWORKS-BFIVE | MIMOSA-NETWORKS-BFIVE-MIB | mimosaTotalRxPower | 1.3.6.1.4.1.43356.2.1.2.6.6 | The total receive power for all the channels on the Mimosa device. |
| Mimosa Networks | MIMOSA-NETWORKS-PTMP | MIMOSA-NETWORKS-PTMP-MIB | mimosaPtmpChPwrTxPowerCur | 1.3.6.1.4.1.43356.2.1.2.9.3.3.1.10 | Describes the current transmit power level. The allowed options are determined by a combination of country and chosen frequency. Measured in dBm |
| Moxa | MOXA-EDSG508E | MOXA-EDSG508E-MIB | fiberTxPower | 1.3.6.1.4.1.8691.7.69.1.10.11.1.7 | The fiber TX power of monitor function |
| Moxa | MOXA-EDSG508E | MOXA-EDSG508E-MIB | fiberRxPower | 1.3.6.1.4.1.8691.7.69.1.10.11.1.9 | The fiber RX power of monitor function |
| Moxa | MOXA-EDSG512E8POE | MOXA-EDSG512E8POE-MIB | fiberTxPower | 1.3.6.1.4.1.8691.7.108.1.10.11.1.7 | The fiber TX power of monitor function |
| Moxa | MOXA-EDSG512E8POE | MOXA-EDSG512E8POE-MIB | fiberRxPower | 1.3.6.1.4.1.8691.7.108.1.10.11.1.9 | The fiber RX power of monitor function |
| Moxa | MOXA-EDSP506E | MOXA-EDSP506E-MIB | fiberTxPower | 1.3.6.1.4.1.8691.7.162.1.10.11.1.7 | The fiber TX power of monitor function |
| Moxa | MOXA-EDSP506E | MOXA-EDSP506E-MIB | fiberRxPower | 1.3.6.1.4.1.8691.7.162.1.10.11.1.9 | The fiber RX power of monitor function |
| Moxa | MOXA-EDSP510A8POE | MOXA-EDSP510A8POE-MIB | sfpTxPower | 1.3.6.1.4.1.8691.7.86.1.10.7.1.5 | The SPF TX power of monitor function |
| Moxa | MOXA-EDSP510A8POE | MOXA-EDSP510A8POE-MIB | sfpRXPower | 1.3.6.1.4.1.8691.7.86.1.10.7.1.6 | The SPF RX power of monitor function |
| Moxa | MOXA-ICSG7826A | MOXA-ICSG7826A-MIB | sfpTxPower | 1.3.6.1.4.1.8691.7.99.1.10.7.1.5 | The SFP TX power(dBm) of monitor function |
| Moxa | MOXA-ICSG7826A | MOXA-ICSG7826A-MIB | sfpRxPower | 1.3.6.1.4.1.8691.7.99.1.10.7.1.6 | The SFP RX power(dBm) of monitor function |
| Moxa | MOXA-IKS6726A | MOXA-IKS6726A-MIB | sfpTxPower | 1.3.6.1.4.1.8691.7.116.1.10.7.1.5 | The SFP TX power(dBm) of monitor function |
| Moxa | MOXA-IKS6726A | MOXA-IKS6726A-MIB | sfpRxPower | 1.3.6.1.4.1.8691.7.116.1.10.7.1.6 | The SFP RX power(dBm) of monitor function |
| Microsens | MS-SWITCH30 | MS-SWITCH30-MIB | sfpTxPower | 1.3.6.1.4.1.3181.10.3.9.10.1.13 | This entry describes the optical transmit power of the sfp in multiple of 0.1 uW. |
| Microsens | MS-SWITCH30 | MS-SWITCH30-MIB | sfpRxPower | 1.3.6.1.4.1.3181.10.3.9.10.1.14 | This entry describes the ooptical receive power of the sfp in multiple of 0.1 uW. |
| NAGTECH LLC | NAG | NAG-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.57206.7.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| NAGTECH LLC | NAG | NAG-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.57206.7.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| NATEKS Ltd. | NATEKS | NATEKS-MIB | sfpDDMRxInputmW | 1.3.6.1.4.1.4249.2.5.9.2.1.7 | Measured RX received optical power from 0 to 6.5535 mW. |
| NATEKS Ltd. | NATEKS | NATEKS-MIB | sfpDDMRxInputdBm | 1.3.6.1.4.1.4249.2.5.9.2.1.8 | Measured RX received optical power from -40 to +8.2 dBm. |
| MRV Communications | NBS-CMMC | NBS-CMMC-MIB | nbsCmmcPortTxPowerLevel | 1.3.6.1.4.1.629.200.8.1.1.65 | This object indicates whether this port has a problem with its transmitter power. If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1). If Digital Diagnostics indicate TxPower is below the low Alarm Threshold, this value should be lowAlarm(2). If Digital Diagnostics indicate TxPower is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3). If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4). If Digital Diagnostics indicate TxPower is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),. If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6). The related object nbsCmmcPortTxPower indicates what the current TxPower is. |
| MRV Communications | NBS-CMMC | NBS-CMMC-MIB | nbsCmmcPortRxPowerLevel | 1.3.6.1.4.1.629.200.8.1.1.66 | This object indicates whether this port has a problem with the power of its received signal. If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1). If Digital Diagnostics indicate RxPower is below the low Alarm Threshold, this value should be lowAlarm(2). If Digital Diagnostics indicate RxPower is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3). If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4). If Digital Diagnostics indicate RxPower is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),. If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6). The related object nbsCmmcPortRxPower indicates what the current RxPower is. |
| MRV Communications | NBS-OSA | NBS-OSA-MIB | nbsOsaSpectrumRxPowerOper | 1.3.6.1.4.1.629.207.2.2.1.5 | The last known signal strength, in millidecibels (mdBm), of this channel. |
| MRV Communications | NBS-OSA | NBS-OSA-MIB | nbsOsaChannelRxPowerOper | 1.3.6.1.4.1.629.207.3.2.1.8 | The last known signal strength, in millidecibels (mdBm), of this channel. Not supported value: -100001 |
| MRV Communications | NBS-SFF | NBS-SFF-MIB | nbsSffDiagsTxPower | 1.3.6.1.4.1.629.204.1.3.1.1.35 | Measured TX output power in the units of dBm. |
| MRV Communications | NBS-SFF | NBS-SFF-MIB | nbsSffDiagsRxPower | 1.3.6.1.4.1.629.204.1.3.1.1.40 | Measured received optical power. Received power, RX_PWR, is given in uW by the following equation: Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD 4 (16 bit unsigned integer) + Rx_PWR(3) * Rx_PWR AD 3 (16 bit unsigned integer) + Rx_PWR(2) * Rx_PWR AD 2 (16 bit unsigned integer) + Rx_PWR(1) * Rx_PWR AD (16 bit unsigned integer) + Rx_PWR(0) |
| MRV Communications | NBS-SIGCOND | NBS-SIGCOND-MIB | nbsSigCondPortRxPower | 1.3.6.1.4.1.629.227.40.2.1.2 | Measured receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000 |
| MRV Communications | NBS-SIGCOND | NBS-SIGCOND-MIB | nbsSigCondPortTxPower | 1.3.6.1.4.1.629.227.40.2.1.3 | Measured transmitter power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000 |
| MRV Communications | NBS-SIGCOND | NBS-SIGCOND-MIB | nbsSigCondChannelRxPower | 1.3.6.1.4.1.629.227.50.2.1.11 | The dynamically measured or calculated receive signal strength |
| MRV Communications | NBS-SIGCOND | NBS-SIGCOND-MIB | nbsSigCondChannelTxPower | 1.3.6.1.4.1.629.227.50.2.1.12 | The dynamically measured or calculated transmit signal strength |
| MRV Communications | NBS-SIGLANE | NBS-SIGLANE-MIB | nbsSigLaneLaneTxPowerLevel | 1.3.6.1.4.1.629.236.20.1.1.20 | This object indicates the status of this lane's measured received power, reported in nbsSigLaneLaneTxPower: notSupported(1), if (nbsSigLaneLaneTxPower = 0x80000000); lowAlarm(2), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMin; lowWarning(3), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMin and nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerUserMin; ok(4), if nbsSigLaneLaneTxPower is within thresholds; highWarning(5), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMax and nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerUserMax; highAlarm(6), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMax |
| MRV Communications | NBS-SIGLANE | NBS-SIGLANE-MIB | nbsSigLaneLaneTxPower | 1.3.6.1.4.1.629.236.20.1.1.21 | The output power (in milli dBm) of this lane. Not supported value: 0x80000000 |
| MRV Communications | NBS-SIGLANE | NBS-SIGLANE-MIB | nbsSigLaneLaneRxPowerLevel | 1.3.6.1.4.1.629.236.20.1.1.30 | This object indicates the status of this lane's measured received power, reported in nbsSigLaneLaneRxPower: notSupported(1), if (nbsSigLaneLaneRxPower = 0x80000000); lowAlarm(2), if nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerVendorMin; lowWarning(3), if nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerVendorMin and nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerUserMin; ok(4), if nbsSigLaneLaneRxPower is within thresholds; highWarning(5), if nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerVendorMax and nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerUserMax; highAlarm(6), if nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerVendorMax |
| MRV Communications | NBS-SIGLANE | NBS-SIGLANE-MIB | nbsSigLaneLaneRxPower | 1.3.6.1.4.1.629.236.20.1.1.31 | The received optical power (in milli dBm) of this lane. Not supported value: 0x80000000 |
| Aginode (Nexans) | NEXANS-BM | NEXANS-BM-MIB | sfpDiagTxOutputPower | 1.3.6.1.4.1.266.20.5.1.1.17 | The current transmitter output power of the SFP module in microwatt. |
| Aginode (Nexans) | NEXANS-BM | NEXANS-BM-MIB | sfpDiagTxOutputPowerDbm | 1.3.6.1.4.1.266.20.5.1.1.18 | The current transmitter output power of the SFP module in dbm. |
| Aginode (Nexans) | NEXANS-BM | NEXANS-BM-MIB | sfpDiagRxIntputPower | 1.3.6.1.4.1.266.20.5.1.1.19 | The current receiver input power of the SFP module in microwatt. |
| Aginode (Nexans) | NEXANS-BM | NEXANS-BM-MIB | sfpDiagRxInputPowerDbm | 1.3.6.1.4.1.266.20.5.1.1.20 | The current receiver input power of the SFP module in dbm. |
| GCOM / Greentech | NGPON | NGPON-MIB | ontRXPower | 1.3.6.1.4.1.13464.1.14.2.4.1.4.1.5 | ont received optical power(dBm). |
| GCOM / Greentech | NGPON | NGPON-MIB | ontTXPower | 1.3.6.1.4.1.13464.1.14.2.4.1.4.1.6 | ont mean optical launch power(dBm). |
| Pacific Broadband Networks | NMS-EPON-OLT-PON-EXT | NMS-EPON-OLT-PON-EXT | txPower | 1.3.6.1.4.1.11606.10.101.107.1.3 | The tx power of optical module. The unit is 0.1DBm. |
| Pacific Broadband Networks | NMS-EPON-OLT-PON-EXT | NMS-EPON-OLT-PON-EXT | rxPower | 1.3.6.1.4.1.11606.10.101.108.1.3 | The rx power of optical module. The unit is 0.1DBm. |
| Pacific Broadband Networks | NMS-EPON-ONU | NMS-EPON-ONU | rxPower | 1.3.6.1.4.1.11606.10.101.10.31.1.2 | Onu CATV module rx power. Unit is 0.1 DBm. |
| Pacific Broadband Networks | NMS-EPON-ONU | NMS-EPON-ONU | opModuleRxPower | 1.3.6.1.4.1.11606.10.101.10.5.1.5 | ONU PON port optical receive power. Unit is 0.1dB. |
| Pacific Broadband Networks | NMS-EPON-ONU | NMS-EPON-ONU | opModuleTxPower | 1.3.6.1.4.1.11606.10.101.10.5.1.6 | ONU PON port optical send power. Unit is 0.1dB. |
| Pacific Broadband Networks | NMS-GPON | NMS-GPON-MIB | gponOltPonPortOpticalParameterTxPower | 1.3.6.1.4.1.11606.10.10.2.2.1.5 | No description published. |
| Pacific Broadband Networks | NMS-GPON | NMS-GPON-MIB | gponOltPonPortOpticalRxPowerRxPower | 1.3.6.1.4.1.11606.10.10.2.3.1.3 | The rx power of optical module. The unit is 0.1DBm. |
| Pacific Broadband Networks | NMS-IF | NMS-IF-MIB | txPower3 | 1.3.6.1.4.1.11606.10.9.63.1.7.1.11 | The tx 3 power of optical module. The unit is 0.01DBm. |
| Pacific Broadband Networks | NMS-IF | NMS-IF-MIB | rxPower3 | 1.3.6.1.4.1.11606.10.9.63.1.7.1.12 | The rx 3 power of optical module. The unit is 0.01DBm. |
| Pacific Broadband Networks | NMS-OPTICAL-PORT | NMS-OPTICAL-PORT-MIB | opIfRxPowerCurr | 1.3.6.1.4.1.11606.10.9.183.1.1.5 | A unique value for each optical interface, that means optical current receive power value. |
| Pacific Broadband Networks | NMS-OPTICAL-PORT | NMS-OPTICAL-PORT-MIB | opIfTxPowerCurr | 1.3.6.1.4.1.11606.10.9.183.1.1.8 | A unique value for each optical interface, that means optical current sending power value. |
| Nortel (Northern Telecom, Ltd.) | NORTEL-OME40G-FAC | NORTEL-OME40G-FAC-MIB | oChRxActOcnPwr | 1.3.6.1.4.1.562.68.11.3.1.1.1.1.11 | Actual Optical Channel receive power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT. |
| Nortel (Northern Telecom, Ltd.) | NORTEL-OME40G-FAC | NORTEL-OME40G-FAC-MIB | oChTxActOcnPwr | 1.3.6.1.4.1.562.68.11.3.1.1.1.1.8 | Actual Optical Channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT. |
| Nortel (Northern Telecom, Ltd.) | NORTEL-OME40G-FAC | NORTEL-OME40G-FAC-MIB | oChTxActOtmPwr | 1.3.6.1.4.1.562.68.11.3.1.2.1.1.12 | Actual optical channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT. |
| Nortel (Northern Telecom, Ltd.) | NORTEL-OME40G-FAC | NORTEL-OME40G-FAC-MIB | oChRxActOtmPwr | 1.3.6.1.4.1.562.68.11.3.1.2.1.1.15 | Actual receive power This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT. |
| ViaLite (tentative) | NSCRTV-EPON-PON-PORT | NSCRTV-EPON-PON-PORT-MIB | PonOpmDiagnosisTXPower | 1.3.6.1.4.1.17409.2.3.3.5.1.6 | ��ģ�鷢�͹��� |
| ViaLite (tentative) | NSCRTV-EPON-PON-PORT | NSCRTV-EPON-PON-PORT-MIB | PonOpmDiagnosisRXPower | 1.3.6.1.4.1.17409.2.3.3.5.1.7 | ��ģ����չ��� |
| ViaLite (tentative) | NSCRTV-HFCEMS-ANALOG | NSCRTV-HFCEMS-ANALOG-MIB | oswInputA | 1.3.6.1.4.1.17409.1.15.4.1.2 | The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| ViaLite (tentative) | NSCRTV-HFCEMS-ANALOG | NSCRTV-HFCEMS-ANALOG-MIB | oswInputB | 1.3.6.1.4.1.17409.1.15.4.1.3 | The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| ViaLite (tentative) | NSCRTV-HFCEMS-ANALOG | NSCRTV-HFCEMS-ANALOG-MIB | oswOutput1 | 1.3.6.1.4.1.17409.1.15.4.1.4 | The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| ViaLite (tentative) | NSCRTV-HFCEMS-ANALOG | NSCRTV-HFCEMS-ANALOG-MIB | oswOutput2 | 1.3.6.1.4.1.17409.1.15.4.1.5 | The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB. |
| SCTE | NSCRTV-HFCEMS-FIBERNODE | NSCRTV-HFCEMS-FIBERNODE-MIB | fnOpticalReceiverPower | 1.3.6.1.4.1.5591.1.5.5.1.2 | No description published. |
| Optical Access Inc. | OA-EFRM-CPE | OA-EFRM-CPE-MIB | oaEfrmSfpDiagnosticTxPower | 1.3.6.1.4.1.6926.1.16.10.1.3.1.6 | Internaly measured Tx output power. Units: 0.01 decibel (dBm) |
| Optical Access Inc. | OA-EFRM-CPE | OA-EFRM-CPE-MIB | oaEfrmSfpDiagnosticRxPower | 1.3.6.1.4.1.6926.1.16.10.1.3.1.7 | Internaly measured Rx input power. Units: 0.01 decibel (dBm) |
| Optical Access Inc. | OA-SFP | OA-SFP-MIB | oaSfpDiagnosticTxPower | 1.3.6.1.4.1.6926.1.18.1.1.3.1.6 | Internaly measured Tx output power. Units: 0.01 decibel (dBm) |
| Optical Access Inc. | OA-SFP | OA-SFP-MIB | oaSfpDiagnosticRxPower | 1.3.6.1.4.1.6926.1.18.1.1.3.1.7 | Internaly measured Rx input power. Units: 0.01 decibel (dBm) |
| Optical Access Inc. | OA-SFP | OA-SFP-MIB | oaMsa300PinMeasRecSigAvrOptPower | 1.3.6.1.4.1.6926.1.18.1.4.3.1.7 | Average received optical power. Units: 0.01 decibel (dBm) |
| Optical Access Inc. | OADWDM | OADWDM-MIB | oaLdOAmplifierCardOutputPower | 1.3.6.1.4.1.6926.1.41.12.2.1.14 | The Optical Amplifier Output Optical Power (in units of 1/100 [0.01 dBm]) |
| Optical Access Inc. | OADWDM | OADWDM-MIB | oaLdCardEntityWdmRxPm | 1.3.6.1.4.1.6926.1.41.4.1.1.16 | Transponder WDM receiver optical power. Indicates the optical power in units of 1/10 dBm. (oaLdCardEntityWdmRxPm is a signed number.) (999) is returned when this feature is not supported or irrelevant. (-999) is returned when signal is too low. |
| Optical Access Inc. | OADWDM | OADWDM-MIB | oaLdCardWdmTxPm | 1.3.6.1.4.1.6926.1.41.3.1.1.16 | Transponder WDM transmitter optical power. Indicates the optical power in dBm. To calculate the power use the equation P(dBm)=oaLdCardWdmTxPm/2, when oaLdCardWdmTxPm is a signed number. (171) is returned when this feature is not supported Note: For TM-DXFP card the optical power are in units of percent (%) |
| GLsun Science and Tech Co. Ltd. | OAP-C1-OEO | OAP-C1-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.1.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C1-OLP | OAP-C1-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.1.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C10-OEO | OAP-C10-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.10.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C10-OLP | OAP-C10-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.10.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C11-OEO | OAP-C11-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.11.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C11-OLP | OAP-C11-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.11.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C12-OEO | OAP-C12-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.12.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C12-OLP | OAP-C12-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.12.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C13-OEO | OAP-C13-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.13.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C13-OLP | OAP-C13-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.13.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C14-OEO | OAP-C14-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.14.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C14-OLP | OAP-C14-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.14.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C15-OEO | OAP-C15-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.15.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C15-OLP | OAP-C15-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.15.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C16-OEO | OAP-C16-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.16.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C16-OLP | OAP-C16-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.16.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C2-OEO | OAP-C2-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.2.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C2-OLP | OAP-C2-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.2.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C3-OEO | OAP-C3-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.3.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C3-OLP | OAP-C3-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.3.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C4-OEO | OAP-C4-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.4.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C4-OLP | OAP-C4-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.4.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C5-OEO | OAP-C5-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.5.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C5-OLP | OAP-C5-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.5.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C6-OEO | OAP-C6-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.6.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C6-OLP | OAP-C6-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.6.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C7-OEO | OAP-C7-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.7.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C7-OLP | OAP-C7-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.7.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C8-OEO | OAP-C8-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.8.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C8-OLP | OAP-C8-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.8.3.21 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C9-OEO | OAP-C9-OEO | vSFPA1TxPower | 1.3.6.1.4.1.40989.10.16.9.2.11.4 | No description published. |
| GLsun Science and Tech Co. Ltd. | OAP-C9-OLP | OAP-C9-OLP | c1TxPower | 1.3.6.1.4.1.40989.10.16.9.3.21 | No description published. |
| Omnitron Systems Technology | OMNITRON | OMNITRON-MIB | portSfpTxPower | 1.3.6.1.4.1.7342.2.1.8.1.12 | SFP Transmission power in dBm |
| Omnitron Systems Technology | OMNITRON | OMNITRON-MIB | portSfpRxPower | 1.3.6.1.4.1.7342.2.1.8.1.13 | SFP Transmission power in dBm |
| Optical Transmission Labs, Inc. | ONS15501 | ONS15501-MIB | ons15501OutputSignalPower | 1.3.6.1.4.1.1869.11.11.2.5 | The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power |
| Optical Transmission Labs, Inc. | ONS15501 | ONS15501-MIB | ons15501OutputSignalPowerMean | 1.3.6.1.4.1.1869.11.11.2.6 | Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (see ons15501OutputSignalPowerTrigger) an alarm is generated. The alarm is cleared when the output optical power is back within 90% of trigger from the mean. |
| PICA8 Inc. | PICA-PRIVATE | PICA-PRIVATE-MIB | sfpTxPower | 1.3.6.1.4.1.35098.1.8.1.7 | The Tx power of sfp ransceiver transfer(dBm). |
| PICA8 Inc. | PICA-PRIVATE | PICA-PRIVATE-MIB | sfpRxPower | 1.3.6.1.4.1.35098.1.8.1.8 | The Rx power of sfp ransceiver transfer(dBm). |
| Pulse Power and Measurement Ltd. | PPM-IGNIS | PPM-IGNIS-MIB | modTx1MonLaserPower | 1.3.6.1.4.1.31225.1.1.4.1.1.22 | Tx1 Current laser power measurement, measured in 10mdBm. |
| B.A.T.M. Advanced Technologies | PRVT-STATISTICS-CES | PRVT-STATISTICS-CES-MIB | prvtLineCurrentOPRs | 1.3.6.1.4.1.738.10.5.114.1.3.1.1.6 | Optical Power Received parameter provides a measurement of the physical layer characteristics of the incoming signal at each optical receiver. |
| B.A.T.M. Advanced Technologies | PRVT-STATISTICS-CES | PRVT-STATISTICS-CES-MIB | prtvLineCurrentOPTs | 1.3.6.1.4.1.738.10.5.114.1.3.1.1.7 | Optical Power Transmitted parameter provides a measurement of the health of the optical transmitter. |
| Ericsson AB | PT-SFP | PT-SFP-MIB | rxPower | 1.3.6.1.4.1.193.223.2.6.1.1.12 | The received light power, in dBm. |
| Ericsson AB | PT-SFP | PT-SFP-MIB | txPower | 1.3.6.1.4.1.193.223.2.6.1.1.13 | The transmit light power, in dBm. |
| Globalcast Communications Inc. | QTECH-ALT | QTECH-ALT-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.2751.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| Globalcast Communications Inc. | QTECH-ALT | QTECH-ALT-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.2751.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| QTECH | QTECH-FIBER | QTECH-FIBER-MIB | qtechFiberRXpowerIntegerpart | 1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.31 | The integer part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Rx power value is -100(means that the value is invalid). |
| QTECH | QTECH-FIBER | QTECH-FIBER-MIB | qtechFiberChannel1RXpowerIntegerpart | 1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.35 | The integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -100(means the value is invalid). |
| QTECH | QTECH-FIBER | QTECH-FIBER-MIB | qtechFiberTXpowerIntegerpart | 1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.51 | The integer part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Tx power value is -100(means that the value is invalid). |
| QTECH | QTECH-FIBER | QTECH-FIBER-MIB | qtechFiberChannel1TXpowerIntegerpart | 1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.54 | The integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -100(means the value is invalid). |
| QTECH | QTECH | QTECH-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.27514.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| QTECH | QTECH | QTECH-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.27514.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| Shanghai Meridian Technologies Co. Ltd. | QTECH-NMS-IF | QTECH-NMS-IF-MIB | txPower | 1.3.6.1.4.1.34751.9.63.1.7.1.2 | The tx power of optical module. The unit is 1DBm. |
| Shanghai Meridian Technologies Co. Ltd. | QTECH-NMS-IF | QTECH-NMS-IF-MIB | rxPower | 1.3.6.1.4.1.34751.9.63.1.7.1.3 | The rx power of optical module. The unit is 1DBm. |
| Shanghai Meridian Technologies Co. Ltd. | QTECH-NMS-OPTICAL-PORT | QTECH-NMS-OPTICAL-PORT-MIB | opIfRxPowerCurr | 1.3.6.1.4.1.34751.9.183.1.1.5 | A unique value for each optical interface, that means optical current receive power value. |
| Shanghai Meridian Technologies Co. Ltd. | QTECH-NMS-OPTICAL-PORT | QTECH-NMS-OPTICAL-PORT-MIB | opIfTxPowerCurr | 1.3.6.1.4.1.34751.9.183.1.1.8 | A unique value for each optical interface, that means optical current sending power value. |
| QTECH | QTECH-RRM | QTECH-RRM-MIB | qtechRrmAPIfRecommendedTxPowerLevel | 1.3.6.1.4.1.27514.1.1.10.2.63.1.4.11.1.2 | Recommended TxPowerLevel by RRM for this APIf |
| RAD Data Communications Ltd. | RAD-GEN | RAD-GEN-MIB | optPrtMonitorTxPower | 1.3.6.1.4.1.164.6.2.15.8.1.1.3 | Transmitted optical power level. Value is given in units of hundredth (1/100) of dBm. |
| RAD Data Communications Ltd. | RAD-GEN | RAD-GEN-MIB | optPrtMonitorRxPower | 1.3.6.1.4.1.164.6.2.15.8.1.1.6 | Received optical power in units of hundredth (1/100) of dBm. |
| Rapid City / Bay Networks (Avaya) | RAPID-CITY | RAPID-CITY | rcPlugOptModTxPower | 1.3.6.1.4.1.2272.1.71.1.1.32 | This value represents the internally measured coupled TX output power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm). |
| Rapid City / Bay Networks (Avaya) | RAPID-CITY | RAPID-CITY | rcPlugOptModRxPower | 1.3.6.1.4.1.2272.1.71.1.1.37 | This value represents the internally measured received power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm). |
| Rapid City / Bay Networks (Avaya) | RAPID-CITY | RAPID-CITY | rcPlugOptModQSFPTx1Power | 1.3.6.1.4.1.2272.1.71.1.1.63 | This value represents the internally measured TX output power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm). |
| Rapid City / Bay Networks (Avaya) | RAPID-CITY | RAPID-CITY | rcPlugOptModQSFPRx1Power | 1.3.6.1.4.1.2272.1.71.1.1.67 | This value represents the internally measured received power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm). |
| SCTE | SCTE-HMS-HE-OPTICAL-AMPLIFIER | SCTE-HMS-HE-OPTICAL-AMPLIFIER-MIB | heOpAmpSetOpticalOutputPower | 1.3.6.1.4.1.5591.1.11.1.3.1.1.4.1.2 | Set Amplifier Optical Output Power. The setting of this value has no effect unless the heOpAmpOutputGainType is set to constantPower(1) |
| SCTE | SCTE-HMS-HE-OPTICAL-RECEIVER | SCTE-HMS-HE-OPTICAL-RECEIVER-MIB | heOpRxInputPower | 1.3.6.1.4.1.5591.1.11.1.2.1.1.1.1.2 | Receiver input power. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm shall be recorded as an entry in the currentAlarmTable of SCTE-HMS-PROPERTY-MIB (HMS026). A log record shall be added as an entry in the heCommonLogTable. An heCommonAlarmEvent notification shall be sent. |
| SCTE | SCTE-HMS-HE-OPTICAL-TRANSMITTER | SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB | heOpTxLaserOutputPower | 1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4 | The laser output power. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm shall be recorded as an entry in the currentAlarmTable of SCTE-HMS-PROPERTY-MIB (HMS026). A log record shall be added as an entry in the heCommonLogTable. An heCommonAlarmEvent notification shall be sent. |
| SIAE Microelettronica S.p.A. | SIAE-SFP | SIAE-SFP-MIB | sfpRxPower | 1.3.6.1.4.1.3373.1103.74.7.1.10 | This contains the internally measured RX optical power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). Located at I2C address 0xa2, Bytes 104 & 105 (MSB, LSB) |
| SIAE Microelettronica S.p.A. | SIAE-SFP | SIAE-SFP-MIB | sfpTxPower | 1.3.6.1.4.1.3373.1103.74.7.1.9 | This contains the internally measured TX output power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). This value is not valid if the transmitter is disabled. Located at I2C address 0xa2, Bytes 102 & 103 (MSB, LSB) |
| PacketLight Networks Ltd. | SL-EDFA | SL-EDFA-MIB | edfaRxPower | 1.3.6.1.4.1.4515.1.9.1.1.1.3 | The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
| PacketLight Networks Ltd. | SL-SFP | SL-SFP-MIB | sfpConfigOptionalWdm | 1.3.6.1.4.1.4515.1.10.1.1.1.23 | The bits in the option field shall specify the options implemented in the transceiver. The following bits are defined: Bits 7: Optional Interrupt Pin Functionality Supported (1 if supported) Bits 6..4: Pilot Tone Functionality 000b: No Pilot Tone Functionality 001b: Pilot Tone Detection Only 010b: Pilot Tone Injection Only 011b: Pilot Tone Injection and Detection 100b: Enhanched Pilot Tone Functionality 101b-111b: Reserved Bits 3: Variable Optical Attenuator Implemented (1 if implemented) Bits 2: Extended Transmit Power Monitoring 0: Default (SFF-8472) TX Power Monitoring 1: Extended TX Power Monitoring (+18.2 dBm max) Bits 1: Wavelength Monitor Type in A2 Byte 106-107 0: Monitor is Wavelength 1: Monitor is Laser Temperature Bits 0: Variable Decision Threshold (1 if implemented) |
| PacketLight Networks Ltd. | SL-SFP | SL-SFP-MIB | sfpDiagTxOutputPower | 1.3.6.1.4.1.4515.1.10.2.1.1.37 | Measured TX output power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor specified wavelength, accuracy shall be better than �3dB over specified temperature and voltage. |
| PacketLight Networks Ltd. | SL-SFP | SL-SFP-MIB | sfpDiagRxInputPower | 1.3.6.1.4.1.4515.1.10.2.1.1.38 | Measured RX input power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor specified wavelength, accuracy shall be better than �3dB over specified temperature and voltage. |
| Dasan Zhone | SLE-DEVICE | SLE-DEVICE-MIB | sleEthernetPortDMIRxPower | 1.3.6.1.4.1.6296.101.2.2.4.1.6 | Measured RX input power. |
| Dasan Zhone | SLE-DEVICE | SLE-DEVICE-MIB | sleEthernetPortDMITxPower | 1.3.6.1.4.1.6296.101.2.2.4.1.5 | Measured TX output power. |
| Dasan Zhone | SLE-EPON | SLE-EPON-MIB | sleEponOltDMITxPower | 1.3.6.1.4.1.6296.101.20.2.7.1.1.4 | onu DMI txpower, range is (-40 ~ 8.1647 dBm). |
| Dasan Zhone | SLE-FAULTMGMT | SLE-FAULTMGMT-MIB | sleAdvaReceivePower | 1.3.6.1.4.1.6296.101.4.9.1.1.10 | Current receive power in dBm as reported by optics. |
| Dasan Zhone | SLE-FAULTMGMT | SLE-FAULTMGMT-MIB | sleAdvaTransmitPower | 1.3.6.1.4.1.6296.101.4.9.1.1.9 | Current transmit power in dBm as reported by optics. |
| Dasan Zhone | SLE-FIBERLAN | SLE-FIBERLAN-MIB | sleFiberLanPERxPower | 1.3.6.1.4.1.6296.101.30.2.1.1.16 | PortExtender's RX power |
| Dasan Zhone | SLE-GPON | SLE-GPON-MIB | sleGponOnuOltRxPower | 1.3.6.1.4.1.6296.101.23.3.1.1.21 | Rx Optical power of olt-side. |
| Dasan Zhone | SLEV2-EPON-IM | SLEV2-EPON-IM-MIB | sleV2EponIMOnuRxOpticPower | 1.3.6.1.4.1.6296.102.15.1.1.1.9 | value of the ONU rx optical power, UNIT : dBm |
| SNR | SNR-SWITCH | SNR-SWITCH-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.40418.7.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| SNR | SNR-SWITCH | SNR-SWITCH-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.40418.7.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| Summit Development, Ltd. | Summitd | Summitd | txPower | 1.3.6.1.4.1.23688.1.1.19 | Actual Transmit Power [dBm] |
| Quanta Computer Inc. | SWITCHING-EXTENSION | SWITCHING-EXTENSION-MIB | agentDOMTxpower | 1.3.6.1.4.1.7244.2.101.1.1.108.1.5 | Tx Power of the transceiver module |
| Quanta Computer Inc. | SWITCHING-EXTENSION | SWITCHING-EXTENSION-MIB | agentDOMRxpower | 1.3.6.1.4.1.7244.2.101.1.1.108.1.6 | Rx Power of the transceiver module |
| Nokia (Alcatel-Lucent / Timetra) | TIMETRA-PORT | TIMETRA-PORT-MIB | tmnxOpticalPortTdcmPowerIn | 1.3.6.1.4.1.6527.3.1.2.2.4.59.1.12 | The value of tmnxOpticalPortTdcmPowerIn indicates the received average optical power at the input the tunable dispersion compensation module. The UNITS millibels (mBm) are units of 0.01 decibel relative to one milliwatt (dBm) or dBm multiplied by 100. The mBm is used when integers are required instead of floating point. For example: -5.21 dBm is equivalent to -521 mBm. |
| Nokia (Alcatel-Lucent / Timetra) | TIMETRA-PORT | TIMETRA-PORT-MIB | tmnxOpticalPortTdcmPowerOut | 1.3.6.1.4.1.6527.3.1.2.2.4.59.1.14 | The value of tmnxOpticalPortTdcmPowerOut indicates the optical power at the output of tunable dispersion compensation module. The UNITS millibels (mBm) are units of 0.01 decibel relative to one milliwatt (dBm) or dBm multiplied by 100. The mBm is used when integers are required instead of floating point. For example: -5.21 dBm is equivalent to -521 mBm. |
| Transition Networks | TN-DDMI | TN-DDMI-MIB | tnDdmiStatusInterfaceA2CurrentTxPower | 1.3.6.1.4.1.868.2.5.152.1.3.2.1.1018 | Current Tx power in mV. |
| Transition Networks | TN-DDMI | TN-DDMI-MIB | tnDdmiStatusInterfaceA2CurrentRxPower | 1.3.6.1.4.1.868.2.5.152.1.3.2.1.1023 | Current Rx power in mV. |
| Transition Networks | TN-MGMT | TN-MGMT-MIB | tnDMITxPowerLevel | 1.3.6.1.4.1.868.2.5.3.1.2.2.1.14 | DMI: Diagnostic Monitoring Interface for fiber transceivers. Transmit power on local fiber measured in microwatts. |
| Transition Networks | TN-MGMT | TN-MGMT-MIB | tnDMIRxPowerLevel | 1.3.6.1.4.1.868.2.5.3.1.2.2.1.16 | DMI: Diagnostic Monitoring Interface for fiber transceivers. Receive power on local fiber measured in microwatts. |
| Tropic Networks | TN-RMD-IF | TN-RMD-IF-MIB | tnRmdIfDdmTxOutputPower | 1.3.6.1.4.1.7483.6.4.1.3.7.1.16 | The value of tnRmdIfDdmTxOutputPower indicates the current Output Power of the interface in one tenths of a micro-Watt (uW). For example: Using the SNMP value of 790, and using units of tenths of microwatt, 790 becomes 79 microwatts or 0.079 milliwatts. Converting to dBm: 10 x log10(0.079) = -11.0 dBm |
| TP-Link Systems Inc. | TPLINK-DDMSTATUS | TPLINK-DDMSTATUS-MIB | ddmStatusTxPow | 1.3.6.1.4.1.11863.6.96.1.7.1.1.5 | This object indicates the tx power of the port. |
| TP-Link Systems Inc. | TPLINK-DDMSTATUS | TPLINK-DDMSTATUS-MIB | ddmStatusRxPow | 1.3.6.1.4.1.11863.6.96.1.7.1.1.6 | This object indicates the rx power of the port. |
| Trango Networks, LLC | TRANGO-P5M | TRANGO-P5M-MIB | rfTxPower | 1.3.6.1.4.1.5454.1.40.2.5 | It specifies tx power. And it will be limited by Min/Max by different band |
| Tropic Networks | TROPIC-AMPLIFIER | TROPIC-AMPLIFIER-MIB | tnAmplifierPortOSCTxPowerOut | 1.3.6.1.4.1.7483.2.2.3.7.5.2.1.11 | The EDFA module OSC transmitted output power of the amplifier card. -9900 indicates no measured power. Current ranges: A2P2125: -1500 to 1100 AA2DONW: -1500 to 1500 AM2032A: -1500 to 1100 AM2125A: -1500 to 1100 AM2125B: -1500 to 1100 AM2318A: -1500 to 1100 AM2625A: 0 to 1500 ASWG: -1500 to 1100 A4PSWG: -1500 to 1100. |
| Tropic Networks | TROPIC-AMPLIFIER | TROPIC-AMPLIFIER-MIB | tnAmplifierPortInfoOSCRxPowerIn | 1.3.6.1.4.1.7483.2.2.3.7.5.2.1.22 | The EDFA module OSC received input power to the card. -9900 indicates no measured power. |
| Tropic Networks | TROPIC-AMPLIFIER | TROPIC-AMPLIFIER-MIB | tnAmplifierPortInfoOSCSfpTxPowerOut | 1.3.6.1.4.1.7483.2.2.3.7.5.2.1.23 | The OSCSFP transceiver output power -9900 indicates no measured power. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnOpsPortTargetReceivedPower | 1.3.6.1.4.1.7483.2.2.4.3.4.212.1.5 | Same value at A and B in ports; per channel. The SW implementation is using the Sig port to access this attribute. Current configurable range: -3150 to 1700. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnOpsPortInfoReceivedPower | 1.3.6.1.4.1.7483.2.2.4.3.5.191.1.1 | The received power in mBm. This is accessible from ports 2 and 3 (working or protected) exclusively. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnIroadmPortInfoOSCTxPowerOut | 1.3.6.1.4.1.7483.2.2.4.3.5.308.1.20 | The EDFA module OSC transmitted output power from the card. -9900 indicates no measured power. Current ranges: -9900,-1200 to 1000. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnIroadmPortInfoOSCRxPowerIn | 1.3.6.1.4.1.7483.2.2.4.3.5.308.1.21 | The EDFA module OSC received input power to the card. -9900 indicates no measured power. Current ranges: -9900,-4400 to 1000. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnIroadmPortInfoOSCSfpTxPowerOut | 1.3.6.1.4.1.7483.2.2.4.3.5.308.1.22 | The OSCSFP transceiver output power. Current ranges: -9900, -1000 to 1000. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnOtPortTxPowerLaser | 1.3.6.1.4.1.7483.2.2.4.3.5.71.1.5 | The transmit power after the MSA transponder and before the VOA. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnOtPortTxLaneBslPowers | 1.3.6.1.4.1.7483.2.2.4.3.5.71.1.9 | Displays CFP transmit lane Baseline powers for the number of lanes supported by a CFP type. Receive lane powers will not be displayed for the following conditions: - A CFP does not provide lane powers - A CFP is not equipped (not present) - A port is not provisioned. - A CFP port Total RX power is not Baselined For a CFP with 4 lanes, here is a sample output: 'TxPwr Lane 1 : -8.00 dBm TxPwr Lane 2 : -8.10 dBm TxPwr Lane 3 : -7.80 dBm TxPwr Lane 4 : -8.30 dBm' including the new line characters. |
| Tropic Networks | TROPIC-OPTICALPORT | TROPIC-OPTICALPORT-MIB | tnOtPortTxLanePowers | 1.3.6.1.4.1.7483.2.2.4.3.5.71.1.7 | Displays CFP transmit lane powers for the number of lanes supported by a CFP type. Transmit lane powers will not be displayed for the following conditions: - A CFP does not provide lane powers - A CFP is not equipped (not present) - A port is not provisioned. For a CFP with 4 lanes, here is a sample output: 'TxPwr Lane 1 : -40.00 dBm TxPwr Lane 2 : -40.00 dBm TxPwr Lane 3 : -40.00 dBm TxPwr Lane 4 : -40.00 dBm' including the new line characters. |
| Ubiquiti | UBNT-EdgeMAX | UBNT-EdgeMAX-MIB | ubntOnuTxPower | 1.3.6.1.4.1.41112.1.5.6.2.1.8 | in hundredths of dBm |
| Ubiquiti | UBNT-EdgeMAX | UBNT-EdgeMAX-MIB | ubntOnuRxPower | 1.3.6.1.4.1.41112.1.5.6.2.1.9 | in hundredths of dBm |
| v-solution | V1600D | V1600D | transceiverTransmitPower | 1.3.6.1.4.1.37950.1.1.5.10.1.1.5.1.5 | No description published. |
| v-solution | V1600D | V1600D | transceiverReceivedPower | 1.3.6.1.4.1.37950.1.1.5.10.1.1.5.1.6 | No description published. |
| Zyxel | VES1724-58V | VES1724-58V-MIB | geDdmiTxPower | 1.3.6.1.4.1.890.1.5.12.49.4.3.1.4 | Measured TX output power in 10^(-4) mW. |
| Zyxel | VES1724-58V | VES1724-58V-MIB | geDdmiRxPower | 1.3.6.1.4.1.890.1.5.12.49.4.3.1.5 | Measured RX received optical power in 10^(-4) mW. |
| Waystream AB | WAYSTREAM | WAYSTREAM-MIB | wsSFPTXdBmPower | 1.3.6.1.4.1.9303.4.1.4.1.22 | Measured TX power (dBm x 1000). |
| Waystream AB | WAYSTREAM | WAYSTREAM-MIB | wsSFPRXdBmPower | 1.3.6.1.4.1.9303.4.1.4.1.23 | Measured RX power (dBm x 1000). |
| Westermo Teleindustri AB | WESTERMO-DDM | WESTERMO-DDM-MIB | ddmPortTxPower | 1.3.6.1.4.1.16177.2.2.1.1.1.6 | Transmit power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm. |
| Westermo Teleindustri AB | WESTERMO-DDM | WESTERMO-DDM-MIB | ddmPortRxPower | 1.3.6.1.4.1.16177.2.2.1.1.1.7 | Receiving power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm. |
| Westermo Teleindustri AB | WESTERMO-WEOS | WESTERMO-WEOS-MIB | sfpDdmPortTxPower | 1.3.6.1.4.1.16177.2.1.2.2.1.1.6 | Transmitt power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm |
| Westermo Teleindustri AB | WESTERMO-WEOS | WESTERMO-WEOS-MIB | sfpDdmPortRxPower | 1.3.6.1.4.1.16177.2.1.2.2.1.1.7 | Receiving power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm |
| CERN | WR-SWITCH | WR-SWITCH-MIB | wrsPortStatusSfpTxPower | 1.3.6.1.4.1.96.100.7.6.1.20 | Measured TX output power in uW reported by SFP. According to SFF-8472, accuracy of this value must be better than 3dB% |
| CERN | WR-SWITCH | WR-SWITCH-MIB | wrsPortStatusSfpRxPower | 1.3.6.1.4.1.96.100.7.6.1.21 | Measured RX output power in uW reported by SFP. According to SFF-8472, accuracy of this value must be better than 3dB% |
| Ciena (World Wide Packets) | WWP-LEOS-PORT-XCVR | WWP-LEOS-PORT-XCVR-MIB | wwpLeosPortXcvrRxDbmPower | 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.105 | Indicates the Rx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000. |
| Ciena (World Wide Packets) | WWP-LEOS-PORT-XCVR | WWP-LEOS-PORT-XCVR-MIB | wwpLeosPortXcvrTxDbmPower | 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.106 | Indicates the Tx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000. |
| Ciena (World Wide Packets) | WWP-LEOS-PORT-XCVR | WWP-LEOS-PORT-XCVR-MIB | wwpLeosPortXcvrRxPower | 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.19 | This represents the measured receive power of the transceiver. Units are micro Watts. |
| National Center for Software Technology (India) | XXX | XXX-MIB | mc2-5g-sfpTranPower | 1.3.6.1.4.1.6688.1.1.1.4.2.10.1.1.1.11 | SFP tx power (one type, signed) |
| National Center for Software Technology (India) | XXX | XXX-MIB | mc2-5g-sfpRecvPower | 1.3.6.1.4.1.6688.1.1.1.4.2.10.1.1.1.12 | SFP rx power (one type, signed) |
| Zelax | ZELAX | ZELAX-MIB | ddmDiagnosisRXPower | 1.3.6.1.4.1.7840.2.1.100.30.1.1.17 | RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'. |
| Zelax | ZELAX | ZELAX-MIB | ddmDiagnosisTXPower | 1.3.6.1.4.1.7840.2.1.100.30.1.1.22 | TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'. |
| Zhone Technologies | ZHNGPONLINK | ZHNGPONLINK | txPower | 1.3.6.1.4.1.5504.2.5.43.1.2.1.8 | GPON interface transmit power, in dBm. |
| Zhone Technologies | ZHNHPNA | ZHNHPNA | hpnaStationRxPower | 1.3.6.1.4.1.5504.2.5.47.1.3.1.7 | HPNA receive power, in dBm. |
| Zhone Technologies | ZHNHPNA | ZHNHPNA | hcnaStationRxPower | 1.3.6.1.4.1.5504.2.5.47.1.4.1.7 | HCNA receive power, in dBm. |
| Zhone Technologies | Zhone-GPON | Zhone-GPON-MIB | zhoneGponOltOpticTxPower | 1.3.6.1.4.1.5504.5.14.1.20.1.4 | Measured Tx Output Power of the OLT in dB. The measured value will be in tenths of dB. |
| Zhone Technologies | Zhone-GPON | Zhone-GPON-MIB | zhoneGponOntRxPower | 1.3.6.1.4.1.5504.5.14.1.7.1.4 | Rx Power as reported by the ONT. The value is in tenths of dB. |
| Zhone Technologies | ZHONE-SFF | ZHONE-SFF | zhoneDDMTxPower | 1.3.6.1.4.1.5504.3.12.1.3.1.4 | Measured Tx output power. |
| Zhone Technologies | ZHONE-SFF | ZHONE-SFF | zhoneDDMRxPower | 1.3.6.1.4.1.5504.3.12.1.3.1.5 | Measured received power. |
| ZTE (Zhongxing Telecom) | ZXR10-OPTICAL-ALARM | ZXR10-OPTICAL-ALARM-MIB | zxr10opticalTxPower | 1.3.6.1.4.1.3902.3.126.1.2.1.3 | No description published. |
| ZTE (Zhongxing Telecom) | ZXR10-OPTICAL-ALARM | ZXR10-OPTICAL-ALARM-MIB | zxr10opticalRxPower | 1.3.6.1.4.1.3902.3.126.1.2.1.4 | No description published. |
| Zyxel | ZYXEL-IES5000 | ZYXEL-IES5000-MIB | sfpTxPower | 1.3.6.1.4.1.890.1.5.13.5.13.13.2.1.12 | No description published. |
| Zyxel | ZYXEL-ves1724-56-Fanless | ZYXEL-ves1724-56-Fanless-MIB | txPower | 1.3.6.1.4.1.890.1.5.12.47.35.7.2.1.1.7 | Transmit power 1: 30 mW 2: 15 mW |
| Zyxel | ZYXEL-ves1724-56 | ZYXEL-ves1724-56-MIB | txPower | 1.3.6.1.4.1.890.1.5.12.46.35.7.2.1.1.7 | Transmit power 1: 30 mW 2: 15 mW |