MIB Viewer

Optical RX/TX Power Catalog

Last updated September 15, 2026

Optical RX/TX power is the signal strength an SFP, XFP, or QSFP transceiver is receiving or transmitting, measured in dBm.

Most transceivers expose this through the SFF-8472 Digital Diagnostics Monitoring standard at the hardware level, but there's no single standardized MIB for collecting this information, so each vendor must define their own.

Search the catalog to filter optical power oids by vendor/model.

VendorModel / PlatformMIBObjectOIDDescription
3ComA3COM-HUAWEI-TRANSCEIVER-INFOA3COM-HUAWEI-TRANSCEIVER-INFO-MIBh3cTransceiverCurRXPower1.3.6.1.4.1.43.45.1.10.2.70.1.1.1.12Indicating the current received power . The unit is in hundredths of dBM.
3ComA3COM-HUAWEI-TRANSCEIVER-INFOA3COM-HUAWEI-TRANSCEIVER-INFO-MIBh3cTransceiverCurTXPower1.3.6.1.4.1.43.45.1.10.2.70.1.1.1.9Indicating the current transmitted power . The unit is in hundredths of dBM.
ADTRANADTRAN-GEN-OPTICAL-AMPLIFIERADTRAN-GEN-OPTICAL-AMPLIFIER-MIBadGenOpticalAmplifierLaserPumpReflectedPower1.3.6.1.4.1.664.5.70.41.1.1.1.11Displays the reflected power at the total output in mA.
ADTRANADTRAN-GEN-OPTICAL-AMPLIFIERADTRAN-GEN-OPTICAL-AMPLIFIER-MIBadGenOpticalAmplifierInputPower1.3.6.1.4.1.664.5.70.41.1.1.1.3Input Power of the Optical Signal to the Amplifier module in dBm.
ADTRANADTRAN-GEN-OPTICAL-AMPLIFIERADTRAN-GEN-OPTICAL-AMPLIFIER-MIBadGenOpticalAmplifierOutputPower1.3.6.1.4.1.664.5.70.41.1.1.1.4Output Power of the Optical Signal from the Amplifier module in dBm.
ADTRANADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXERADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIBadGenOpticalADMProvChannelPowerLevel1.3.6.1.4.1.664.5.70.43.2.1.1.2This OID defines the channel power level reference for all the channels coming in on ADD-IN or EXP-IN interfaces to be auto power balanced. This value will be used when auto power balance is enabled
ADTRANADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXERADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIBadGenOpticalADMProvChannelPower1.3.6.1.4.1.664.5.70.43.3.1.1.8This OID can be used to set the channel power level. This value will be used if auto power balancing is disabled. The channels coming in on ADD-IN or EXP-IN interfaces will be attenuated to this power level. This is only used when the power control override on the channel level is set to power mode.
ADTRANADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXERADTRAN-GENERIC-OPTICAL-ADD-DROP-MULTIPLEXER-MIBadGenOpticalADMChannelStatOcmChannelPower1.3.6.1.4.1.664.5.70.43.6.2.1.1This displays the Channel current power value of the selected index.
ADTRANADTRAN-GENGPONADTRAN-GENGPON-MIBadGenGponOntRxPower1.3.6.1.4.1.664.6.10000.76.1.1.3.1.1.32The ONT's receive optical signal level. It is a measurement of the OLT's optical launch power (tenths of dBm), received by the ONT's optical transceiver. The default value -9999 indicates that the value is not available.
ADTRANADTRAN-GENGPONADTRAN-GENGPON-MIBadGenGponOntTxPower1.3.6.1.4.1.664.6.10000.76.1.1.3.1.1.33The ONT's transmit optical signal level. It is a measurement of the ONT's optical launch power (tenths of dBm). The default value -9999 indicates that the value is not available.
ADTRANADTRAN-GENGPONADTRAN-GENGPON-MIBadGenGponOntVideoReturnPathRxCurrentPower1.3.6.1.4.1.664.6.10000.76.1.1.4.7.1.7Power level of the last burst received(unit dBmV).
ADTRANADTRAN-GENTA8XXADTRAN-GENTA8XX-MIBadGenTA8xxGigEthSFPTxPower1.3.6.1.4.1.664.5.69.2.3.3.1.10A textual representation of the current transmit power of the SFP. Note that only SFPs that support SFF8472 Release 9.3 or higher support this status.
ADTRANADTRAN-GENTA8XXADTRAN-GENTA8XX-MIBadGenTA8xxGigEthSFPRxPower1.3.6.1.4.1.664.5.69.2.3.3.1.11A textual representation of the current receive power of the SFP. Note that only SFPs that support SFF8472 Release 9.3 or higher support this status.
ADTRANADTRAN-PLUGGABLE-PORTADTRAN-PLUGGABLE-PORT-MIBadGenPluggablePortRxPower1.3.6.1.4.1.664.5.70.4.1.1.1.21Reports the receive power of the pluggable port in units reported by adGenPluggablePortRxPowerUnits. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development.
ADTRANADTRAN-PLUGGABLE-PORTADTRAN-PLUGGABLE-PORT-MIBadGenPluggablePortRxPowerUnits1.3.6.1.4.1.664.5.70.4.1.1.1.22Reports the units of adGenPluggablePortRxPower. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development.
ADTRANADTRAN-PLUGGABLE-PORTADTRAN-PLUGGABLE-PORT-MIBadGenPluggablePortTxPower1.3.6.1.4.1.664.5.70.4.1.1.1.23Reports the transmit power of the pluggable port in units reported by adGenPluggablePortTxPowerUnits. This object is deprecated for new development. Please use the relevant OID in the adGenPluggablePortChannelTable for new development.
ADTRANADTRAN-TA5K-SMADTRAN-TA5K-SM-MIBadTa5kSmNet1SFPRxPowerLevel1.3.6.1.4.1.664.2.750.1.1.1.12This displays transceiver RX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions
ADTRANADTRAN-TA5K-SMADTRAN-TA5K-SM-MIBadTa5kSmNet1SFPTxPowerLevel1.3.6.1.4.1.664.2.750.1.1.1.13This displays transceiver TX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions
ADTRANADTRAN-TA5K-SMADTRAN-TA5K-SM-MIBadTa5kSmNet2SFPRxPowerLevel1.3.6.1.4.1.664.2.750.1.1.1.19This displays transceiver RX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions
ADTRANADTRAN-TA5K-SMADTRAN-TA5K-SM-MIBadTa5kSmNet2SFPTxPowerLevel1.3.6.1.4.1.664.2.750.1.1.1.20This displays transceiver TX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions
ADVA Optical NetworkingADVA-FSPR7ADVA-FSPR7-MIBphysicalPortOutputPower1.3.6.1.4.1.2544.1.11.7.3.4.1.1.12Instantaneous Optical Power Transmitted (Output)
ADVA Optical NetworkingADVA-FSPR7ADVA-FSPR7-MIBvirtualPortOutputPower1.3.6.1.4.1.2544.1.11.7.3.4.2.1.15Instantaneous Optical Power Transmitted (Output)
ADVA Optical NetworkingADVA-FSPR7ADVA-FSPR7-MIBpmSnapshotCurrentOutputPower1.3.6.1.4.1.2544.1.11.7.7.2.3.1.1Instantaneous Optical Power Transmitted (Output).
ADVA Optical NetworkingADVA-FSPR7-PMADVA-FSPR7-PM-MIBoptMuxPhysInstValueOutputPower1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.26Instantaneous Optical Power Transmitted (Output)
ADVA Optical NetworkingADVA-FSPR7-PMADVA-FSPR7-PM-MIBoptMuxPhysInstValueOscOutputPower1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.30Instantaneous OSC Optical Power Transmitted (Output)
ADVA Optical NetworkingADVA-FSPR7-PMADVA-FSPR7-PM-MIBoptMuxPhysInstValuePowerPerChannelTx1.3.6.1.4.1.2544.1.11.11.17.2.1.1.1.32Target output optical power for each channel.
Alcatel-Lucent EnterpriseALCATEL-ENT1-PORTALCATEL-ENT1-PORT-MIBddmTxOutputPower1.3.6.1.4.1.6486.801.1.2.1.5.1.1.2.5.1.16The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable.
Alcatel-Lucent EnterpriseALCATEL-ENT1-PORTALCATEL-ENT1-PORT-MIBddmPortTxOutputPower1.3.6.1.4.1.6486.801.1.2.1.5.1.1.2.6.1.17The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable.
Laurel Networks, Inc.APOLLOAPOLLO-MIBapolloTrRxPower1.3.6.1.4.1.5395.3.7.5.1.5Actual Rx Power received on the transceiver.Its value is expressed in dBm
Laurel Networks, Inc.APOLLOAPOLLO-MIBapolloTrTxPower1.3.6.1.4.1.5395.3.7.5.1.6Actual Tx Power transmitted on the transceiver.Its value is expressed in dBm
Laurel Networks, Inc.APOLLOAPOLLO-MIBapolloTrRxPowerLane11.3.6.1.4.1.5395.3.7.5.1.23Rx Power Lane 1. Its value is expressed in dBm
Laurel Networks, Inc.APOLLOAPOLLO-MIBapolloTrTxPowerLane11.3.6.1.4.1.5395.3.7.5.1.31Tx Power Lane 1. Its value is expressed in dBm
Allied TelesisAT-FIBER-MONITORINGAT-FIBER-MONITORING-MIBatFiberMonReading1.3.6.1.4.1.207.8.4.4.3.27.1.1The current received optical power reading for the port specified in the trap (x0.0001mW)
Allied TelesisAT-FIBER-MONITORINGAT-FIBER-MONITORING-MIBatFiberMonLastReading1.3.6.1.4.1.207.8.4.4.3.27.3.1.9The most recent reading of rx power, in units of 0.0001mW. -1 is returned if no readings have been taken yet.
Allied TelesisAT-PLUGGABLE-DIAGNOSTICSAT-PLUGGABLE-DIAGNOSTICS-MIBatPluggableDiagTxPowerChannel1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2The channel number of the pluggable.
Allied TelesisAT-PLUGGABLE-DIAGNOSTICSAT-PLUGGABLE-DIAGNOSTICS-MIBatPluggableDiagTxPowerStatusReading1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3The current Tx Power (mW) status reading.
Allied TelesisAT-PLUGGABLE-DIAGNOSTICSAT-PLUGGABLE-DIAGNOSTICS-MIBatPluggableDiagRxPowerStatusReading1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3The current Rx Power (mW) status reading.
SynOpticsBAY-STACK-SFFBAY-STACK-SFF-MIBbsDdiSfpTxPowerValue1.3.6.1.4.1.45.5.29.1.2.1.19The actual transmit power value, measured in 1/10000 dBm.
SynOpticsBAY-STACK-SFFBAY-STACK-SFF-MIBbsDdiSfpRxPowerValue1.3.6.1.4.1.45.5.29.1.2.1.24The actual receive power value, measured in 1/10000 dBm.
Broadcom LimitedBRCM-CM-FACTORYBRCM-CM-FACTORY-MIBcmUsCalTxPower1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used.
BrocadeBROCADE-OPTICAL-MONITORINGBROCADE-OPTICAL-MONITORING-MIBbcsiOptMonLaneTxPower1.3.6.1.4.1.1588.3.1.8.1.1.1.4This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
BrocadeBROCADE-OPTICAL-MONITORINGBROCADE-OPTICAL-MONITORING-MIBbcsiOptMonLaneRxPower1.3.6.1.4.1.1588.3.1.8.1.1.1.7This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
BrocadeBROCADE-OPTICAL-MONITORINGBROCADE-OPTICAL-MONITORING-MIBbcsiOptMonTxPower1.3.6.1.4.1.1588.3.1.8.1.2.1.3This object holds the value of the transmitter optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G optic, this returns the aggregated Tx Power for all lanes.
BrocadeBROCADE-OPTICAL-MONITORINGBROCADE-OPTICAL-MONITORING-MIBbcsiOptMonRxPower1.3.6.1.4.1.1588.3.1.8.1.2.1.6This object holds the value of the receiver optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Rx Power for all lanes.
BTI SystemsBTI-7000BTI-7000-MIBoaSSIOpticalPwrReceived1.3.6.1.4.1.18070.2.2.1.4.1.1.20The optical power received on the second stage of the amplifier. It applies to mid-stage access amplifiers only.
BTI SystemsBTI-7000BTI-7000-MIBoaFSOOpticalPwrTransmitted1.3.6.1.4.1.18070.2.2.1.4.1.1.34The optical power transmitted at the output of the first stage of the amplifier. It applies to mid-stage access amplifiers only.
BTI SystemsBTI-7000BTI-7000-MIBamdOpticalPwrTransmitted1.3.6.1.4.1.18070.2.2.1.4.3.1.11The optical power level transmitted for the channel.
BTI SystemsBTI-OLBTI-OL-MIBolOSCCrntPMOPRValue1.3.6.1.4.1.18070.2.2.1.16.12.1.1.6The OSC optical power received on the Line port.
BTI SystemsBTI-OLBTI-OL-MIBolOSCCrntPMOPTValue1.3.6.1.4.1.18070.2.2.1.16.12.1.1.9The OSC optical power transmitted at the output of the Line port.
BTI SystemsBTI-OLBTI-OL-MIBwchCrntPMOPTValue1.3.6.1.4.1.18070.2.2.1.16.12.6.1.19The instantaneous optical power transmitted on the channel.
BTI SystemsBTI-OLBTI-OL-MIBwchCrntPMOPRValue1.3.6.1.4.1.18070.2.2.1.16.12.6.1.8The instantaneous optical power received on the channel.
Casa Systems, Inc.CASA-SFPCASA-SFP-MIBcasaSfpTxPower1.3.6.1.4.1.20858.10.37.1.1.1.7The optical Tx power of the sfp(sfp+).
Casa Systems, Inc.CASA-SFPCASA-SFP-MIBcasaSfpRxPower1.3.6.1.4.1.20858.10.37.1.1.1.8The optical Rx power of the sfp(sfp+).
Cerent (Cisco optical)CERENT-MSDWDMCERENT-MSDWDM-MIBcMsDwdmIfTransportAddPower1.3.6.1.4.1.3607.2.40.1.2.1.16This object is used to specify the ADD optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource.
Cerent (Cisco optical)CERENT-MSDWDMCERENT-MSDWDM-MIBcMsDwdmIfTransportOSCPower1.3.6.1.4.1.3607.2.40.1.2.1.17This object is used to specify the OSC optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource.
Cerent (Cisco optical)CERENT-MSDWDMCERENT-MSDWDM-MIBcMsDwdmIfChannelPower1.3.6.1.4.1.3607.2.40.1.4.1.3This object is used to specify the optical power read at the photodiode of the port. The distinguished value of '-1000' indicates that the power cannot be read due to unavaible HW resource.
CienaCIENA-CES-PMCIENA-CES-PMcienaCesPmBasicPtpCurrBinOptOch1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.12Optical Power Transmit, Optical Channel.
CienaCIENA-CES-PMCIENA-CES-PMcienaCesPmBasicPtpCurrBinOprnOts1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.17Total Normalized Optical Power Receive, Optical Channel.
CienaCIENA-CES-PMCIENA-CES-PMcienaCesPmBasicPtpCurrBinOprnOch1.3.6.1.4.1.1271.2.3.1.2.3.13.2.1.8Normalized Optical Power Receive, Optical Channel.
CienaCIENA-CES-PMCIENA-CES-PMcienaCesPmBasicPtpTotalStatsBinOptOch1.3.6.1.4.1.1271.2.3.1.2.3.13.6.1.7Optical Power Transmit, Optical Channel.
CienaCIENA-WS-PMCIENA-WS-PM-MIBcwsPmBasicCurrentOpticalRxPowerActual1.3.6.1.4.1.1271.3.4.22.68.1.2Actual power reading.
CienaCIENA-WS-PTPCIENA-WS-PTP-MIBcwsXcvrRxPowerActual1.3.6.1.4.1.1271.3.4.8.11.1.2Actual Tx or Rx optical power in dBm.
CienaCIENA-WS-PTPCIENA-WS-PTP-MIBcwsXcvrTxPowerActual1.3.6.1.4.1.1271.3.4.8.13.1.2Actual Tx or Rx optical power in dBm.
CienaCIENA-WS-PTP-MODEMCIENA-WS-PTP-MODEM-MIBcwsXcvrColourlessRxChannelPowerActual1.3.6.1.4.1.1271.3.4.9.26.1.2Actual Tx or Rx optical power in dBm.
CienaCIENA-WS-XCVRCIENA-WS-XCVR-MIBcwsXcvrVendorDiagnosticMonitoringRxPowerMeasurement1.3.6.1.4.1.1271.3.4.15.12.1.2Rx power measurement, bit 3 of diagnostic monitoring type. Reference SFF 8472 section 8.8 and table 9.5 for detail.
CienaCIENA-WS-XCVRCIENA-WS-XCVR-MIBcwsXcvrVendorDiagnosticMonitoringTxPowerMeasurement1.3.6.1.4.1.1271.3.4.15.12.1.3Tx ower measurement, related to diagnostic monitoring type.
CienaCIENA-WS-XCVRCIENA-WS-XCVR-MIBcwsXcvrChannelRxPowerActual1.3.6.1.4.1.1271.3.4.15.17.1.2Actual Rx optical power in dBm.
CienaCIENA-WS-XCVRCIENA-WS-XCVR-MIBcwsXcvrChannelTxPowerActual1.3.6.1.4.1.1271.3.4.15.20.1.2Actual Tx optical power in dBm.
CiscoCISCO-LWAPP-CCX-RMCISCO-LWAPP-CCX-RM-MIBclcrClientRxPowerSignal1.3.6.1.4.1.9.9.520.1.4.1.1.2This object represents the signal strength of the beacon or probe response frame as seen by the client.
CiscoCISCO-OPTICALCISCO-OPTICAL-MIBcoiOpticalControllerTransmitPower1.3.6.1.4.1.9.9.828.1.1.2.1.5This object is used to configure the Transmit Power in 1/100 dBm on optical channel interfaces.
CiscoCISCO-OPTICALCISCO-OPTICAL-MIBcoiOpticalControllerPerLaneRXPower1.3.6.1.4.1.9.9.828.1.1.3.1.2This object specifies the Receive power in 1/100 dBm.
CiscoCISCO-OPTICALCISCO-OPTICAL-MIBcoiOpticalControllerPerLaneTXPower1.3.6.1.4.1.9.9.828.1.1.3.1.3This object specifies the Transmit power in 1/100 dBm.
CiscoCISCO-OPTICAL-MONITORINGCISCO-OPTICAL-MONITORING-MIBcomTxPower1.3.6.1.4.1.9.10.83.1.1.1.1.3This object holds the value of the transmitter optical power for the interface being instrumented. The optical is proportional to the laser diode current. This object makes sense only if comTxPowerSupported is true. All values must be converted to microWatts.
CiscoCISCO-OPTICAL-OTSCISCO-OPTICAL-OTS-MIBcooOtsOchControllerTXPower1.3.6.1.4.1.9.9.834.1.1.3.1.4This object represents the transmit power in 1/100 dBm on optical OTS-OCH interfaces.
CiscoCISCO-OPTICAL-OTSCISCO-OPTICAL-OTS-MIBcooOtsControllerTotalRXPower1.3.6.1.4.1.9.9.834.1.1.2.1.7This object is used to represents the total receive power in 1/100 dBm on optical OTS interfaces.
CiscoCISCO-OPTICAL-OTSCISCO-OPTICAL-OTS-MIBcooOtsControllerTotalTXPower1.3.6.1.4.1.9.9.834.1.1.2.1.8This object is used to represents the total transmit power in 1/100 dBm on optical OTS interfaces.
ADVA Optical NetworkingCM-PERFORMANCECM-PERFORMANCE-MIBcmEthernetNetPortStatsOPT1.3.6.1.4.1.2544.1.12.5.1.5.1.33Optical Power Transmit (in dBm) for the physical layer. This is applicable only if the media type for the Network Port is fiber.
ADVA Optical NetworkingCM-PERFORMANCECM-PERFORMANCE-MIBcmEthernetNetPortStatsOPR1.3.6.1.4.1.2544.1.12.5.1.5.1.34Optical Power Receive (in dBm) for the physical layer. This is applicable only if the media type for the Network Port is fiber.
ADVA Optical NetworkingCM-PERFORMANCECM-PERFORMANCE-MIBocnStmStatsLineOPT1.3.6.1.4.1.2544.1.12.5.1.46.1.6Transmit Optical Power retrieved from the SFP.
ADVA Optical NetworkingCM-PERFORMANCECM-PERFORMANCE-MIBocnStmStatsLineOPR1.3.6.1.4.1.2544.1.12.5.1.46.1.7Received Optical Power retrieved from the SFP.
Pepperl+Fuchs ComtrolCOMTROL-ES8510COMTROL-ES8510-MIBportSfpDdmTxPowerCurrent1.3.6.1.4.1.2882.2.1.1.3.2.2.1.7The current SFP Transmitted Power of port.
Pepperl+Fuchs ComtrolCOMTROL-ES8510COMTROL-ES8510-MIBportSfpDdmRxPowerCurrent1.3.6.1.4.1.2882.2.1.1.3.2.2.1.9The current SFP Receiveed Power of port.
Check Point Software TechnologiesCPVIEWCPVIEW-MIBorchestratorPortsPortsTableRxPowerLanes1.3.6.1.4.1.2620.1.56.302.1.1.29No description published.
Check Point Software TechnologiesCPVIEWCPVIEW-MIBorchestratorPortsPortsTableTxPowerLanes1.3.6.1.4.1.2620.1.56.302.1.1.30No description published.
CTC UnionCTC-FRM220CTC-FRM220-MIBf100ISDDTxPWRRemoteA1.3.6.1.4.1.4756.20.181.20.1.49RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Tx power
CTC UnionCTC-FRM220CTC-FRM220-MIBf100ISDDRxPWRRemoteA1.3.6.1.4.1.4756.20.181.20.1.50RemoteA FRM220-10/100IS-2 card fiber1 D/D information: Rx power
CTC UnionCTC-FRM220CTC-FRM220-MIBf10GMUXLineDDTxPWRLocal1.3.6.1.4.1.4756.20.700.20.1.106Local FRM220-TM-10GMUX card Line D/D information: Tx power
CTC UnionCTC-FRM220CTC-FRM220-MIBf10GMUXLineDDRxPWRLocal1.3.6.1.4.1.4756.20.700.20.1.107Local FRM220-TM-10GMUX card Line D/D information: Rx power
CTC UnionCTC-FRM220CTC-FRM220-MIBf100GE2QClient3TxPower1.3.6.1.4.1.4756.20.710.20.1.101Local FRM220-100GE-2Q Line Card Client3 Transmit Power.
CTC UnionCTC-FRM220CTC-FRM220-MIBf100GE2QClient3RxPower1.3.6.1.4.1.4756.20.710.20.1.102Local FRM220-100GE-2Q Line Card Client3 Receive Power.
Cyan Inc.CYAN-GEPORTCYAN-GEPORT-MIBcyanGEPortRxPwr1.3.6.1.4.1.28533.5.30.160.1.1.1.13RX Power
Cyan Inc.CYAN-GEPORTCYAN-GEPORT-MIBcyanGEPortTxPwr1.3.6.1.4.1.28533.5.30.160.1.1.1.16TX Power
Cyan Inc.CYAN-TENGPORTCYAN-TENGPORT-MIBcyanTENGPortRxPwr1.3.6.1.4.1.28533.5.30.150.1.1.1.14RX Power
Cyan Inc.CYAN-TENGPORTCYAN-TENGPORT-MIBcyanTENGPortTxPwr1.3.6.1.4.1.28533.5.30.150.1.1.1.18TX Power
Dasan ZhoneDASAN-GIGABIT-OPTIC-TRANSCEIVERDASAN-GIGABIT-OPTIC-TRANSCEIVER-MIBdsGOTransceiverDiagTxPower1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.4Measured TX output power.
Dasan ZhoneDASAN-GIGABIT-OPTIC-TRANSCEIVERDASAN-GIGABIT-OPTIC-TRANSCEIVER-MIBdsGOTransceiverDiagRxPower1.3.6.1.4.1.6296.9.1.1.2.13.1.3.1.1.5Measured RX input power.
DCN (Digital China Networks)DCNDCN-MIBddmDiagnosisRXPower1.3.6.1.4.1.6339.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
DCN (Digital China Networks)DCNDCN-MIBddmDiagnosisTXPower1.3.6.1.4.1.6339.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
D-LinkDDM-MGMTDDM-MGMT-MIBswDdmTxPower1.3.6.1.4.1.171.12.72.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDDM-MGMTDDM-MGMT-MIBswDdmRxPower1.3.6.1.4.1.171.12.72.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
Dell (Force10)DELL-NETWORKING-CHASSISDELL-NETWORKING-CHASSIS-MIBdellNetSysIfXfpTxPower1.3.6.1.4.1.6027.3.26.1.4.10.1.7The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
D-LinkDES-1210-10MEbxDES-1210-10MEbxddmTxPower1.3.6.1.4.1.171.10.75.14.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-10MEbxDES-1210-10MEbxddmRxPower1.3.6.1.4.1.171.10.75.14.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-26ME-B2DES-1210-26ME-B2ddmTxPower1.3.6.1.4.1.171.10.75.16.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-26ME-B2DES-1210-26ME-B2ddmRxPower1.3.6.1.4.1.171.10.75.16.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-28ME-B2DES-1210-28ME-B2ddmTxPower1.3.6.1.4.1.171.10.75.15.2.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-28ME-B2DES-1210-28ME-B2ddmRxPower1.3.6.1.4.1.171.10.75.15.2.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-28ME-B3DES-1210-28ME-B3ddmTxPower1.3.6.1.4.1.171.10.75.15.3.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDES-1210-28ME-B3DES-1210-28ME-B3ddmRxPower1.3.6.1.4.1.171.10.75.15.3.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-10ME_AXDGS-1210-10ME_AXddmTxPower1.3.6.1.4.1.171.10.76.32.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-10ME_AXDGS-1210-10ME_AXddmRxPower1.3.6.1.4.1.171.10.76.32.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-12TSME-BXDGS-1210-12TSME-BXddmTxPower1.3.6.1.4.1.171.10.76.44.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-12TSME-BXDGS-1210-12TSME-BXddmRxPower1.3.6.1.4.1.171.10.76.44.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-20ME_AXDGS-1210-20ME_AXddmTxPower1.3.6.1.4.1.171.10.76.31.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-20ME_AXDGS-1210-20ME_AXddmRxPower1.3.6.1.4.1.171.10.76.31.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28ME_AXDGS-1210-28ME_AXddmTxPower1.3.6.1.4.1.171.10.76.28.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28ME_AXDGS-1210-28ME_AXddmRxPower1.3.6.1.4.1.171.10.76.28.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28PME_AXDGS-1210-28PME_AXddmTxPower1.3.6.1.4.1.171.10.76.30.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28PME_AXDGS-1210-28PME_AXddmRxPower1.3.6.1.4.1.171.10.76.30.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28XME-BXDGS-1210-28XME-BXddmTxPower1.3.6.1.4.1.171.10.76.43.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28XME-BXDGS-1210-28XME-BXddmRxPower1.3.6.1.4.1.171.10.76.43.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28XSME-BXDGS-1210-28XSME-BXddmTxPower1.3.6.1.4.1.171.10.76.39.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-28XSME-BXDGS-1210-28XSME-BXddmRxPower1.3.6.1.4.1.171.10.76.39.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-52ME_AXDGS-1210-52ME_AXddmTxPower1.3.6.1.4.1.171.10.76.29.1.105.2.1.1.1.5This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
D-LinkDGS-1210-52ME_AXDGS-1210-52ME_AXddmRxPower1.3.6.1.4.1.171.10.76.29.1.105.2.1.1.1.6This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
D-LinkDLINKSW-DDMDLINKSW-DDM-MIBdDdmIfInfoCurrentTxPower1.3.6.1.4.1.171.14.72.1.4.1.1.19This object indicates the current output power in unit of 'tenths of a microwatt' on the interface.
D-LinkDLINKSW-DDMDLINKSW-DDM-MIBdDdmIfInfoCurrentRxPower1.3.6.1.4.1.171.14.72.1.4.1.1.25This object indicates the current input power in unit of 'tenths of a microwatt' on the interface.
Datacom (Teracom Telematica Ltda.)DMswitchDMswitch-MIBddTransceiversTxPowerValue1.3.6.1.4.1.3709.3.5.201.1.28.1.1.10Transceiver tx power infomation
Datacom (Teracom Telematica Ltda.)DMswitchDMswitch-MIBddTransceiversRxPower1.3.6.1.4.1.3709.3.5.201.1.28.1.1.4Transceiver rx power information in Decibels
Datacom (Teracom Telematica Ltda.)DMswitchDMswitch-MIBddTransceiversTxPower1.3.6.1.4.1.3709.3.5.201.1.28.1.1.5Transceiver tx power information in Decibels
Datacom (Teracom Telematica Ltda.)DMswitchDMswitch-MIBddTransceiversRxPowerValue1.3.6.1.4.1.3709.3.5.201.1.28.1.1.9Transceiver rx power infomation
Actelis NetworksE5-110E5-110-MIBenetSfpInfoTxpower1.3.6.1.4.1.6321.1.2.3.1.13.17.2.1.1Measured Tx Output Power.
Actelis NetworksE5-110E5-110-MIBenetSfpInfoRxpower1.3.6.1.4.1.6321.1.2.3.1.13.17.2.1.2Measured Rx Output Power.
Actelis NetworksE5-111E5-111-MIBenetSfpInfoTxpower1.3.6.1.4.1.6321.1.2.3.2.13.17.2.1.1Measured Tx Output Power.
Actelis NetworksE5-111E5-111-MIBenetSfpInfoRxpower1.3.6.1.4.1.6321.1.2.3.2.13.17.2.1.2Measured Rx Output Power.
Actelis NetworksE5-120E5-120-MIBenetSfpInfoTxpower1.3.6.1.4.1.6321.1.2.3.3.13.16.2.1.1Measured Tx Output Power.
Actelis NetworksE5-120E5-120-MIBenetSfpInfoRxpower1.3.6.1.4.1.6321.1.2.3.3.13.16.2.1.2Measured Rx Output Power.
Actelis NetworksE5-120E5-120-MIBldmXturAggregateTxPower1.3.6.1.4.1.6321.1.2.3.3.4.4.12Actual Aggregate Transmit Power.
Actelis NetworksE5-120E5-120-MIBldmXtucAggregateTxPower1.3.6.1.4.1.6321.1.2.3.3.4.4.7Actual Aggregate Transmit Power.
Actelis NetworksE5-121E5-121-MIBenetSfpInfoTxpower1.3.6.1.4.1.6321.1.2.3.4.13.16.2.1.1Measured Tx Output Power.
Actelis NetworksE5-121E5-121-MIBenetSfpInfoRxpower1.3.6.1.4.1.6321.1.2.3.4.13.16.2.1.2Measured Rx Output Power.
Actelis NetworksE5-121E5-121-MIBldmXturAggregateTxPower1.3.6.1.4.1.6321.1.2.3.4.4.4.12Actual Aggregate Transmit Power.
Actelis NetworksE5-121E5-121-MIBldmXtucAggregateTxPower1.3.6.1.4.1.6321.1.2.3.4.4.4.7Actual Aggregate Transmit Power.
EkinopsEKINOPS-Pm10001otu4EKINOPS-Pm10001otu4-MIBpm10001otu4MesrclientNetTxPwrPortn1.3.6.1.4.1.20044.82.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm10001otu4EKINOPS-Pm10001otu4-MIBpm10001otu4MesrclientNetRxPwrPortn1.3.6.1.4.1.20044.82.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm10001otu4EKINOPS-Pm10001otu4-MIBpm10001otu4MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.82.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm10001otu4EKINOPS-Pm10001otu4-MIBpm10001otu4MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.82.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mpEKINOPS-Pm10010mp-MIBpm10010mpMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.58.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mpEKINOPS-Pm10010mp-MIBpm10010mpMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.58.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mpEKINOPS-Pm10010mp-MIBpm10010mpMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.58.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mpEKINOPS-Pm10010mp-MIBpm10010mpMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.58.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mptEKINOPS-Pm10010mpt-MIBpm10010mptMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.60.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mptEKINOPS-Pm10010mpt-MIBpm10010mptMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.60.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mptEKINOPS-Pm10010mpt-MIBpm10010mptMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.60.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mptEKINOPS-Pm10010mpt-MIBpm10010mptMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.60.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mrEKINOPS-Pm10010mr-MIBpm10010mrMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.63.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mrEKINOPS-Pm10010mr-MIBpm10010mrMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.63.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm10010mrEKINOPS-Pm10010mr-MIBpm10010mrMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.63.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm10010mrEKINOPS-Pm10010mr-MIBpm10010mrMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.63.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm10010ulhEKINOPS-Pm10010ulh-MIBpm10010ulhMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.80.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm10010ulhEKINOPS-Pm10010ulh-MIBpm10010ulhMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.80.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm10010ulhEKINOPS-Pm10010ulh-MIBpm10010ulhMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.80.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm10010ulhEKINOPS-Pm10010ulh-MIBpm10010ulhMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.80.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm1001IMEKINOPS-Pm1001IM-MIBpm1001imMesrclientTxPowerMeas1.3.6.1.4.1.20044.15.3.2.211Client XFP Transmitted Power :This OID gives the transmit power value of the XFP or OTX plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1001IMEKINOPS-Pm1001IM-MIBpm1001imMesrclientRxPowerMeas1.3.6.1.4.1.20044.15.3.2.212Client XFP Received Power :This OID gives the receive power value of the XFP or OTX plugged in port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1001IMEKINOPS-Pm1001IM-MIBpm1001imMesrlineTxpwrMeasPortn1.3.6.1.4.1.20044.15.3.3.40.1.2Line SFP Transmitted Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1001IMEKINOPS-Pm1001IM-MIBpm1001imMesrlineRxpwrMeasPortn1.3.6.1.4.1.20044.15.3.3.48.1.2Line SFP Received Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-PM1001LHEKINOPS-PM1001LH-MIBpm1001lhMesrclientTxPowerMeas1.3.6.1.4.1.20044.10.3.2.40Client Optical Module Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-PM1001LHEKINOPS-PM1001LH-MIBpm1001lhMesrclientRxPowerMeas1.3.6.1.4.1.20044.10.3.2.48Client Optical Module Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-PM1001LHEKINOPS-PM1001LH-MIBpm1001lhMesrlineTxPowerMeas1.3.6.1.4.1.20044.10.3.3.211Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-PM1001LHEKINOPS-PM1001LH-MIBpm1001lhMesrlineRxPowerMeas1.3.6.1.4.1.20044.10.3.3.212Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1001lhrEKINOPS-Pm1001lhr-MIBpm1001lhrMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.22.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1001lhrEKINOPS-Pm1001lhr-MIBpm1001lhrMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.22.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-PM1001PCEKINOPS-PM1001PC-MIBpm1001pcMesrclientTxPowerMeas1.3.6.1.4.1.20044.12.3.2.40Client Optical Module Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-PM1001PCEKINOPS-PM1001PC-MIBpm1001pcMesrclientRxPowerMeas1.3.6.1.4.1.20044.12.3.2.48Client Optical Module Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-PM1001PCEKINOPS-PM1001PC-MIBpm1001pcMesrlineTxPowerMeas1.3.6.1.4.1.20044.12.3.3.211Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-PM1001PCEKINOPS-PM1001PC-MIBpm1001pcMesrlineRxPowerMeas1.3.6.1.4.1.20044.12.3.3.212Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1001RREKINOPS-Pm1001RR-MIBpm1001rrMesrclientTxPower1.3.6.1.4.1.20044.8.3.2.19Line 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm1001RREKINOPS-Pm1001RR-MIBpm1001rrMesrclientRxPower1.3.6.1.4.1.20044.8.3.2.20Line 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm1001RREKINOPS-Pm1001RR-MIBpm1001rrMesrlineTxPower1.3.6.1.4.1.20044.8.3.3.27Line 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm1001RREKINOPS-Pm1001RR-MIBpm1001rrMesrlineRxPower1.3.6.1.4.1.20044.8.3.3.28Line 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm1004EKINOPS-Pm1004-MIBpm1004MesrtxpwrMeasPortn1.3.6.1.4.1.20044.18.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1004EKINOPS-Pm1004-MIBpm1004MesrrxpwrMeasPortn1.3.6.1.4.1.20044.18.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1004EKINOPS-Pm1004-MIBpm1004Mesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.18.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceive r
EkinopsEKINOPS-Pm1004EKINOPS-Pm1004-MIBpm1004Mesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.18.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1004dcpEKINOPS-Pm1004dcp-MIBpm1004dcpMesrtxpwrMeasPortn1.3.6.1.4.1.20044.37.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1004dcpEKINOPS-Pm1004dcp-MIBpm1004dcpMesrrxpwrMeasPortn1.3.6.1.4.1.20044.37.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1004dcpEKINOPS-Pm1004dcp-MIBpm1004dcpMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.37.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1004dcpEKINOPS-Pm1004dcp-MIBpm1004dcpMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.37.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1004mEKINOPS-Pm1004m-MIBpm1004mMesrtxpwrMeasPortn1.3.6.1.4.1.20044.29.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1004mEKINOPS-Pm1004m-MIBpm1004mMesrrxpwrMeasPortn1.3.6.1.4.1.20044.29.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1004mEKINOPS-Pm1004m-MIBpm1004mMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.29.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1004mEKINOPS-Pm1004m-MIBpm1004mMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.29.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1004VEKINOPS-Pm1004V-MIBpm1004vMesrtxpwrMeasPortn1.3.6.1.4.1.20044.32.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1004VEKINOPS-Pm1004V-MIBpm1004vMesrrxpwrMeasPortn1.3.6.1.4.1.20044.32.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1004VEKINOPS-Pm1004V-MIBpm1004vMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.32.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1004VEKINOPS-Pm1004V-MIBpm1004vMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.32.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1004VDCEKINOPS-Pm1004VDC-MIBpm1004vdcMesrtxpwrMeasPortn1.3.6.1.4.1.20044.38.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1004VDCEKINOPS-Pm1004VDC-MIBpm1004vdcMesrrxpwrMeasPortn1.3.6.1.4.1.20044.38.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1004VDCEKINOPS-Pm1004VDC-MIBpm1004vdcMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.38.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1004VDCEKINOPS-Pm1004VDC-MIBpm1004vdcMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.38.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1004vencEKINOPS-Pm1004venc-MIBpm1004vencMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.43.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1004vencEKINOPS-Pm1004venc-MIBpm1004vencMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.43.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1005EKINOPS-Pm1005-MIBpm1005MesrtxpwrMeasPortn1.3.6.1.4.1.20044.26.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1005EKINOPS-Pm1005-MIBpm1005MesrrxpwrMeasPortn1.3.6.1.4.1.20044.26.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1005EKINOPS-Pm1005-MIBpm1005Mesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.26.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1005EKINOPS-Pm1005-MIBpm1005Mesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.26.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1008EKINOPS-Pm1008-MIBpm1008MesrtxpwrMeasPortn1.3.6.1.4.1.20044.3.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1008EKINOPS-Pm1008-MIBpm1008MesrrxpwrMeasPortn1.3.6.1.4.1.20044.3.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1008EKINOPS-Pm1008-MIBpm1008Mesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.3.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1008EKINOPS-Pm1008-MIBpm1008Mesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.3.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1008DCPEKINOPS-Pm1008DCP-MIBpm1008dcpMesrtxpwrMeasPortn1.3.6.1.4.1.20044.27.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm1008DCPEKINOPS-Pm1008DCP-MIBpm1008dcpMesrrxpwrMeasPortn1.3.6.1.4.1.20044.27.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm1008DCPEKINOPS-Pm1008DCP-MIBpm1008dcpMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.27.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm1008DCPEKINOPS-Pm1008DCP-MIBpm1008dcpMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.27.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line , read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm100gaggEKINOPS-Pm100gagg-MIBpm100gaggMesrclientRxPwrPortn1.3.6.1.4.1.20044.91.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm100gaggEKINOPS-Pm100gagg-MIBpm100gaggMesrclientTxPwrPortn1.3.6.1.4.1.20044.91.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm100gaggEKINOPS-Pm100gagg-MIBpm100gaggMesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.91.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gaggEKINOPS-Pm100gagg-MIBpm100gaggMesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.91.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gemuxEKINOPS-Pm100gemux-MIBpm100gemuxMesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.103.3.2.256.1.2Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gemuxEKINOPS-Pm100gemux-MIBpm100gemuxMesrclientTxPwrPortn1.3.6.1.4.1.20044.103.3.2.272.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm100gemuxEKINOPS-Pm100gemux-MIBpm100gemuxMesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.103.3.2.288.1.2Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gemuxEKINOPS-Pm100gemux-MIBpm100gemuxMesrclientRxPwrPortn1.3.6.1.4.1.20044.103.3.2.304.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm100gemuxsfpEKINOPS-Pm100gemuxsfp-MIBpm100gemuxsfpMesrclientRxPwrPortn1.3.6.1.4.1.20044.107.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm100gemuxsfpEKINOPS-Pm100gemuxsfp-MIBpm100gemuxsfpMesrclientTxPwrPortn1.3.6.1.4.1.20044.107.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm100gemuxsfpEKINOPS-Pm100gemuxsfp-MIBpm100gemuxsfpMesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.107.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gemuxsfpEKINOPS-Pm100gemuxsfp-MIBpm100gemuxsfpMesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.107.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gfmuxdEKINOPS-Pm100gfmuxd-MIBpm100gfmuxdMesrclientRxPwrPortn1.3.6.1.4.1.20044.111.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm100gfmuxdEKINOPS-Pm100gfmuxd-MIBpm100gfmuxdMesrclientTxPwrPortn1.3.6.1.4.1.20044.111.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm100gfmuxdEKINOPS-Pm100gfmuxd-MIBpm100gfmuxdMesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.111.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gfmuxdEKINOPS-Pm100gfmuxd-MIBpm100gfmuxdMesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.111.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gxponderEKINOPS-Pm100gxponder-MIBpm100gxponderMesrclientRxPwrPortn1.3.6.1.4.1.20044.113.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm100gxponderEKINOPS-Pm100gxponder-MIBpm100gxponderMesrclientTxPwrPortn1.3.6.1.4.1.20044.113.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm100gxponderEKINOPS-Pm100gxponder-MIBpm100gxponderMesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.113.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm100gxponderEKINOPS-Pm100gxponder-MIBpm100gxponderMesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.113.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pm124EKINOPS-Pm124-MIBpm124MesrclientTxPowerPortn1.3.6.1.4.1.20044.16.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm124EKINOPS-Pm124-MIBpm124MesrclientRxPowerPortn1.3.6.1.4.1.20044.16.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm124EKINOPS-Pm124-MIBpm124MesrlineTxPowerPortn1.3.6.1.4.1.20044.16.3.3.67.1.2Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm124EKINOPS-Pm124-MIBpm124MesrlineRxPowerPortn1.3.6.1.4.1.20044.16.3.3.68.1.2Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm124feEKINOPS-Pm124fe-MIBpm124feMesrclientTxPowerPortn1.3.6.1.4.1.20044.44.3.2.40.1.2Client SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm124feEKINOPS-Pm124fe-MIBpm124feMesrclientRxPowerPortn1.3.6.1.4.1.20044.44.3.2.48.1.2Client SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm124feEKINOPS-Pm124fe-MIBpm124feMesrlineTxPowerPortn1.3.6.1.4.1.20044.44.3.3.67.1.2Line SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm124feEKINOPS-Pm124fe-MIBpm124feMesrlineRxPowerPortn1.3.6.1.4.1.20044.44.3.3.68.1.2Line SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm1604EKINOPS-Pm1604-MIBpm1604Mesrline1TxPowerPortn1.3.6.1.4.1.20044.77.3.2.40.1.2Line 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm1604EKINOPS-Pm1604-MIBpm1604Mesrline1RxPowerPortn1.3.6.1.4.1.20044.77.3.2.48.1.2Line 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm1604EKINOPS-Pm1604-MIBpm1604Mesrline2TxPowerPortn1.3.6.1.4.1.20044.77.3.3.44.1.2Line 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm1604EKINOPS-Pm1604-MIBpm1604Mesrline2RxPowerPortn1.3.6.1.4.1.20044.77.3.3.52.1.2Line 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm20002maEKINOPS-Pm20002ma-MIBpm20002maMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.73.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm20002maEKINOPS-Pm20002ma-MIBpm20002maMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.73.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm20020maEKINOPS-Pm20020ma-MIBpm20020maMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.69.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm20020maEKINOPS-Pm20020ma-MIBpm20020maMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.69.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm20020maEKINOPS-Pm20020ma-MIBpm20020maMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.69.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm20020maEKINOPS-Pm20020ma-MIBpm20020maMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.69.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm200fr20EKINOPS-Pm200fr20-MIBpm200fr20MesrclientRxPwrPortn1.3.6.1.4.1.20044.87.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pm200fr20EKINOPS-Pm200fr20-MIBpm200fr20MesrclientTxPwrPortn1.3.6.1.4.1.20044.87.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pm200fr20EKINOPS-Pm200fr20-MIBpm200fr20MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.87.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm200fr20EKINOPS-Pm200fr20-MIBpm200fr20MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.87.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm200frs02EKINOPS-Pm200frs02-MIBpm200frs02MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.90.3.2.256.1.2Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver
EkinopsEKINOPS-Pm200frs02EKINOPS-Pm200frs02-MIBpm200frs02MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.90.3.2.288.1.2Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver
EkinopsEKINOPS-Pm200frs02EKINOPS-Pm200frs02-MIBpm200frs02MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.90.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm200frs02EKINOPS-Pm200frs02-MIBpm200frs02MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.90.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm251dEKINOPS-Pm251d-MIBpm251dMesrclientTxpwrMeasPortn1.3.6.1.4.1.20044.31.3.2.40.1.2Client SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm251dEKINOPS-Pm251d-MIBpm251dMesrclientRxpwrMeasPortn1.3.6.1.4.1.20044.31.3.2.48.1.2Client SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm251dEKINOPS-Pm251d-MIBpm251dMesrlineTxpwrMeasPortn1.3.6.1.4.1.20044.31.3.3.163.1.2Line SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm251dEKINOPS-Pm251d-MIBpm251dMesrlineRxpwrMeasPortn1.3.6.1.4.1.20044.31.3.3.164.1.2Line SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm253EKINOPS-Pm253-MIBpm253MesrclientTxpwrMeasPortn1.3.6.1.4.1.20044.13.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm253EKINOPS-Pm253-MIBpm253MesrclientRxpwrMeasPortn1.3.6.1.4.1.20044.13.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm253EKINOPS-Pm253-MIBpm253MesrlineTxpwrMeasPortn1.3.6.1.4.1.20044.13.3.3.163.1.2Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm253EKINOPS-Pm253-MIBpm253MesrlineRxpwrMeasPortn1.3.6.1.4.1.20044.13.3.3.164.1.2Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm254dEKINOPS-Pm254d-MIBpm254dMesrclientTxpwrMeasPortn1.3.6.1.4.1.20044.17.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pm254dEKINOPS-Pm254d-MIBpm254dMesrclientRxpwrMeasPortn1.3.6.1.4.1.20044.17.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pm254dEKINOPS-Pm254d-MIBpm254dMesrlineTxpwrMeasPortn1.3.6.1.4.1.20044.17.3.3.163.1.2Line SFP Tx Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pm254dEKINOPS-Pm254d-MIBpm254dMesrlineRxpwrMeasPortn1.3.6.1.4.1.20044.17.3.3.164.1.2Line SFP Rx Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pm400fr05EKINOPS-Pm400fr05-MIBpm400fr05MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.118.3.2.256.1.2Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver
EkinopsEKINOPS-Pm400fr05EKINOPS-Pm400fr05-MIBpm400fr05MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.118.3.2.288.1.2Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver
EkinopsEKINOPS-Pm400fr05EKINOPS-Pm400fr05-MIBpm400fr05MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.118.3.3.144.1.2Current Line Trscv Tx Laser Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the current Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm400frs04EKINOPS-Pm400frs04-MIBpm400frs04MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.100.3.2.256.1.2Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver
EkinopsEKINOPS-Pm400frs04EKINOPS-Pm400frs04-MIBpm400frs04MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.100.3.2.288.1.2Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver
EkinopsEKINOPS-Pm400frs04EKINOPS-Pm400frs04-MIBpm400frs04MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.100.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm400frs04EKINOPS-Pm400frs04-MIBpm400frs04MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.100.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm404EKINOPS-Pm404-MIBpm404Mesrline1TxPowerPortn1.3.6.1.4.1.20044.25.3.2.40.1.2Line 1 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm404EKINOPS-Pm404-MIBpm404Mesrline1RxPowerPortn1.3.6.1.4.1.20044.25.3.2.48.1.2Line 1 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm404EKINOPS-Pm404-MIBpm404Mesrline2TxPowerPortn1.3.6.1.4.1.20044.25.3.3.44.1.2Line 2 SFP Tx Power :This OID gives the transmit power value of the SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm404EKINOPS-Pm404-MIBpm404Mesrline2RxPowerPortn1.3.6.1.4.1.20044.25.3.3.52.1.2Line 2 SFP Rx Power :This OID gives the receive power value of the SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm600frs06EKINOPS-Pm600frs06-MIBpm600frs06MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.115.3.2.256.1.2Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver
EkinopsEKINOPS-Pm600frs06EKINOPS-Pm600frs06-MIBpm600frs06MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.115.3.2.288.1.2Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver
EkinopsEKINOPS-Pm600frs06EKINOPS-Pm600frs06-MIBpm600frs06MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.115.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm600frs06EKINOPS-Pm600frs06-MIBpm600frs06MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.115.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pm800fr04EKINOPS-Pm800fr04-MIBpm800fr04MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.120.3.2.256.1.2Client Composite Tx Power :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-30) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver
EkinopsEKINOPS-Pm800fr04EKINOPS-Pm800fr04-MIBpm800fr04MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.120.3.2.288.1.2Client Composite Rx Power :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-30) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver
EkinopsEKINOPS-Pm800fr04EKINOPS-Pm800fr04-MIBpm800fr04MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.120.3.3.144.1.2Current Line Optical Module Tx Laser Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the current Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pm801RREKINOPS-Pm801RR-MIBpm801rrMesrclientTxPower1.3.6.1.4.1.20044.48.3.2.19Line 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm801RREKINOPS-Pm801RR-MIBpm801rrMesrclientRxPower1.3.6.1.4.1.20044.48.3.2.20Line 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver
EkinopsEKINOPS-Pm801RREKINOPS-Pm801RR-MIBpm801rrMesrlineTxPower1.3.6.1.4.1.20044.48.3.3.27Line 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver
EkinopsEKINOPS-Pm801RREKINOPS-Pm801RR-MIBpm801rrMesrlineRxPower1.3.6.1.4.1.20044.48.3.3.28Line 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver
EkinopsEKINOPS-PmapcEKINOPS-Pmapc-MIBpmapcMesrpowerLas11.3.6.1.4.1.20044.42.3.2.16Stuff, Wavelength 1 Power :This OID gives the power value of the Sutfing Wavelength 1 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the optical power of the Stuffing Wavelength 1 Laser
EkinopsEKINOPS-PmapcEKINOPS-Pmapc-MIBpmapcMesrpowerLas21.3.6.1.4.1.20044.42.3.3.24Stuff, Wavelength 2 Power :This OID gives the power value of the Sutfing Wavelength 2 Laser (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the optical power of the Stuffing Wavelength 2 Laser
EkinopsEKINOPS-PMC1002EKINOPS-PMC1002-MIBpmc1002MesrclientTxPowerMeasPortn1.3.6.1.4.1.20044.50.3.2.40.1.2Client SFP+ Tx Power :This OID gives the transmit power value of the XFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-PMC1002EKINOPS-PMC1002-MIBpmc1002MesrclientRxPowerMeasPortn1.3.6.1.4.1.20044.50.3.2.48.1.2Client SFP+ Rx Power :This OID gives the receive power value of the XFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-PMC1002EKINOPS-PMC1002-MIBpmc1002Mesrline1TxPowerMeasPortn1.3.6.1.4.1.20044.50.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-PMC1002EKINOPS-PMC1002-MIBpmc1002Mesrline1RxPowerMeasPortn1.3.6.1.4.1.20044.50.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-Pmc1008MPEKINOPS-Pmc1008MP-MIBpmc1008mpMesrtxpwrMeasPortn1.3.6.1.4.1.20044.47.3.2.40.1.2Client SFP Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-Pmc1008MPEKINOPS-Pmc1008MP-MIBpmc1008mpMesrrxpwrMeasPortn1.3.6.1.4.1.20044.47.3.2.48.1.2Client SFP Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-Pmc1008MPEKINOPS-Pmc1008MP-MIBpmc1008mpMesrxfp1LoTxPowerMeasPortn1.3.6.1.4.1.20044.47.3.3.211.1.2Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-Pmc1008MPEKINOPS-Pmc1008MP-MIBpmc1008mpMesrxfp1LiRxPowerMeasPortn1.3.6.1.4.1.20044.47.3.3.212.1.2Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-PMC2002EKINOPS-PMC2002-MIBpmc2002MesrclientTxPowerMeasPortn1.3.6.1.4.1.20044.52.3.2.40.1.2SFP+ Tx Power :This OID gives the transmit power value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the client transceiver
EkinopsEKINOPS-PMC2002EKINOPS-PMC2002-MIBpmc2002MesrclientRxPowerMeasPortn1.3.6.1.4.1.20044.52.3.2.48.1.2SFP+ Rx Power :This OID gives the receive power value of the SFP plugged into port, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the client transceiver
EkinopsEKINOPS-PMC2002EKINOPS-PMC2002-MIBpmc2002Mesrline1TxPowerMeasPortn1.3.6.1.4.1.20044.52.3.3.211.1.2OTX TLH Tx Power :This OID gives the transmit power value of the OTX TLH plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line transceiver
EkinopsEKINOPS-PMC2002EKINOPS-PMC2002-MIBpmc2002Mesrline1RxPowerMeasPortn1.3.6.1.4.1.20044.52.3.3.212.1.2OTX TLH Rx Power :This OID gives the receive power value of the OTX TLH plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
EkinopsEKINOPS-PmcryptoEKINOPS-Pmcrypto-MIBpmcryptoMesrclientRxPwrPortn1.3.6.1.4.1.20044.96.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-PmcryptoEKINOPS-Pmcrypto-MIBpmcryptoMesrclientTxPwrPortn1.3.6.1.4.1.20044.96.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-PmcryptoEKINOPS-Pmcrypto-MIBpmcryptoMesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.96.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-PmcryptoEKINOPS-Pmcrypto-MIBpmcryptoMesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.96.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pmcryptoe100EKINOPS-Pmcryptoe100-MIBpmcryptoe100MesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.101.3.2.256.1.2Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pmcryptoe100EKINOPS-Pmcryptoe100-MIBpmcryptoe100MesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.101.3.2.288.1.2Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pmcryptoe100EKINOPS-Pmcryptoe100-MIBpmcryptoe100MesrlineTxCompositePwrPortn1.3.6.1.4.1.20044.101.3.3.160.1.2Line Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pmcryptoe100EKINOPS-Pmcryptoe100-MIBpmcryptoe100MesrlineRxCompositePwrPortn1.3.6.1.4.1.20044.101.3.3.192.1.2Line Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Line Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Pme1008EKINOPS-Pme1008-MIBpme1008MesrclientTxPwrPortn1.3.6.1.4.1.20044.79.3.2.48.1.2Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pme1008EKINOPS-Pme1008-MIBpme1008MesrclientRxPwrPortn1.3.6.1.4.1.20044.79.3.2.64.1.2Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pme1008EKINOPS-Pme1008-MIBpme1008MesrlineRxPwrPortn1.3.6.1.4.1.20044.79.3.3.128.1.2Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pme1008EKINOPS-Pme1008-MIBpme1008MesrlineTxPwrPortn1.3.6.1.4.1.20044.79.3.3.80.1.2Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pmlma10EKINOPS-Pmlma10-MIBpmlma10MesrclientTxPwrPortn1.3.6.1.4.1.20044.68.3.2.48.1.2Client Optical Module Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pmlma10EKINOPS-Pmlma10-MIBpmlma10MesrclientRxPwrPortn1.3.6.1.4.1.20044.68.3.2.64.1.2Client Optical Module Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pmlma10EKINOPS-Pmlma10-MIBpmlma10MesrlineRxPwrPortn1.3.6.1.4.1.20044.68.3.3.128.1.2Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pmlma10EKINOPS-Pmlma10-MIBpmlma10MesrlineTxPwrPortn1.3.6.1.4.1.20044.68.3.3.80.1.2Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-PmMCEKINOPS-PmMC-MIBpmmcMesrline1TxPower1.3.6.1.4.1.20044.21.3.2.19Line 1 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 1 transceiver
EkinopsEKINOPS-PmMCEKINOPS-PmMC-MIBpmmcMesrline1RxPower1.3.6.1.4.1.20044.21.3.2.20Line 1 SFP Rx Power :This OID gives the receive power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 1 transceiver
EkinopsEKINOPS-PmMCEKINOPS-PmMC-MIBpmmcMesrline2TxPower1.3.6.1.4.1.20044.21.3.3.27Line 2 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the line 2 transceiver
EkinopsEKINOPS-PmMCEKINOPS-PmMC-MIBpmmcMesrline2RxPower1.3.6.1.4.1.20044.21.3.3.28Line 2 SFP Rx Power :This OID gives the receive power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line 2 transceiver
EkinopsEKINOPS-Pmo10010EKINOPS-Pmo10010-MIBpmo10010MesrclientNetTxPwrPortn1.3.6.1.4.1.20044.76.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pmo10010EKINOPS-Pmo10010-MIBpmo10010MesrclientNetRxPwrPortn1.3.6.1.4.1.20044.76.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pmo10010EKINOPS-Pmo10010-MIBpmo10010MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.76.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pmo10010EKINOPS-Pmo10010-MIBpmo10010MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.76.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Pmo1008mpEKINOPS-Pmo1008mp-MIBpmo1008mpMesrclientTxPwrPortn1.3.6.1.4.1.20044.121.3.2.48.1.2Client Optical Module Tx Power :This OID gives the transmit power value of the Client Optical Module, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Optical Module
EkinopsEKINOPS-Pmo1008mpEKINOPS-Pmo1008mp-MIBpmo1008mpMesrclientRxPwrPortn1.3.6.1.4.1.20044.121.3.2.64.1.2Client Optical Module Rx Power :This OID gives the receive power value of the Client Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Optical Module
EkinopsEKINOPS-Pmo1008mpEKINOPS-Pmo1008mp-MIBpmo1008mpMesrlineRxPwrPortn1.3.6.1.4.1.20044.121.3.3.128.1.2Line Optical Module Rx Power :This OID gives the Receive power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Optical Module
EkinopsEKINOPS-Pmo1008mpEKINOPS-Pmo1008mp-MIBpmo1008mpMesrlineTxPwrPortn1.3.6.1.4.1.20044.121.3.3.80.1.2Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Optical Module
EkinopsEKINOPS-Pmo5005EKINOPS-Pmo5005-MIBpmo5005MesrclientTxPwrPortn1.3.6.1.4.1.20044.119.3.2.48.1.2Client Optical Module Tx Power :This OID gives the transmit power value of the Client Optical Module, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Optical Module
EkinopsEKINOPS-Pmo5005EKINOPS-Pmo5005-MIBpmo5005MesrclientRxPwrPortn1.3.6.1.4.1.20044.119.3.2.64.1.2Client Optical Module Rx Power :This OID gives the receive power value of the Client Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Optical Module
EkinopsEKINOPS-Pmo5005EKINOPS-Pmo5005-MIBpmo5005MesrlineRxPwrPortn1.3.6.1.4.1.20044.119.3.3.128.1.2Line Optical Module Rx Power :This OID gives the Receive power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Optical Module
EkinopsEKINOPS-Pmo5005EKINOPS-Pmo5005-MIBpmo5005MesrlineTxPwrPortn1.3.6.1.4.1.20044.119.3.3.80.1.2Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Optical Module, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Optical Module
EkinopsEKINOPS-Pmo6006EKINOPS-Pmo6006-MIBpmo6006MesrclientTxPwrPortn1.3.6.1.4.1.20044.70.3.2.48.1.2Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Pmo6006EKINOPS-Pmo6006-MIBpmo6006MesrclientRxPwrPortn1.3.6.1.4.1.20044.70.3.2.64.1.2Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Pmo6006EKINOPS-Pmo6006-MIBpmo6006MesrlineRxPwrPortn1.3.6.1.4.1.20044.70.3.3.128.1.2Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Pmo6006EKINOPS-Pmo6006-MIBpmo6006MesrlineTxPwrPortn1.3.6.1.4.1.20044.70.3.3.80.1.2Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-PmOaEKINOPS-PmOa-MIBpmoaMesrclientEdfaTxpwrMeas1.3.6.1.4.1.20044.9.3.2.33Pre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Pre-Amp
EkinopsEKINOPS-PmOaEKINOPS-PmOa-MIBpmoaMesrclientEdfaRxpwrMeas1.3.6.1.4.1.20044.9.3.2.34Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster
EkinopsEKINOPS-PmOaEKINOPS-PmOa-MIBpmoaMesrlineEdfaTxpwrMeas1.3.6.1.4.1.20044.9.3.3.41Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster
EkinopsEKINOPS-PmOaEKINOPS-PmOa-MIBpmoaMesrlineEdfaRxpwrMeas1.3.6.1.4.1.20044.9.3.3.42Pre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Pre-Amp
EkinopsEKINOPS-PmOabEKINOPS-PmOab-MIBpmoabMesrclientEdfaRxpwrMeas1.3.6.1.4.1.20044.23.3.2.34Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster
EkinopsEKINOPS-PmOabEKINOPS-PmOab-MIBpmoabMesrlineEdfaTxpwrMeas1.3.6.1.4.1.20044.23.3.3.41Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster
EkinopsEKINOPS-PmOabphcEKINOPS-PmOabphc-MIBpmoabphcMesrclientEdfaTxpwrMeas1.3.6.1.4.1.20044.51.3.2.33Pre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Pre-Amp
EkinopsEKINOPS-PmOabphcEKINOPS-PmOabphc-MIBpmoabphcMesrclientEdfaRxpwrMeas1.3.6.1.4.1.20044.51.3.2.34Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Booster
EkinopsEKINOPS-PmOabphcEKINOPS-PmOabphc-MIBpmoabphcMesrlineEdfaTxpwrMeas1.3.6.1.4.1.20044.51.3.3.41Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the Booster
EkinopsEKINOPS-PmOabphcEKINOPS-PmOabphc-MIBpmoabphcMesrlineEdfaRxpwrMeas1.3.6.1.4.1.20044.51.3.3.42Pre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the Pre-Amp
EkinopsEKINOPS-PmoabphcsEKINOPS-Pmoabphcs-MIBpmoabphcsMesrclientMsaOutputPower1.3.6.1.4.1.20044.61.3.2.40Pre-Amp MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Pre-Amp (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the Pre-Amp
EkinopsEKINOPS-PmoabphcsEKINOPS-Pmoabphcs-MIBpmoabphcsMesrclientMsaInputPower1.3.6.1.4.1.20044.61.3.2.39Pre-Amp MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Pre-Amp (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the Pre-Amp
EkinopsEKINOPS-PmoabphcsEKINOPS-Pmoabphcs-MIBpmoabphcsMesrlineMsaOutputPower1.3.6.1.4.1.20044.61.3.3.56Booster MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the Booster (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the Booster
EkinopsEKINOPS-PmoabphcsEKINOPS-Pmoabphcs-MIBpmoabphcsMesrlineMsaInputPower1.3.6.1.4.1.20044.61.3.3.55Booster MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the Booster (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the Booster
EkinopsEKINOPS-Pmoac20ilEKINOPS-Pmoac20il-MIBpmoac20ilMesrclientMsaOutputPower1.3.6.1.4.1.20044.114.3.2.40IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Pmoac20ilEKINOPS-Pmoac20il-MIBpmoac20ilMesrclientMsaInputPower1.3.6.1.4.1.20044.114.3.2.39IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Pmoac20ilEKINOPS-Pmoac20il-MIBpmoac20ilMesrlineOscTxPowerPortn1.3.6.1.4.1.20044.114.3.3.64.1.2OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver
EkinopsEKINOPS-Pmoac20ilEKINOPS-Pmoac20il-MIBpmoac20ilMesrlineOscRxPowerPortn1.3.6.1.4.1.20044.114.3.3.65.1.2OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver
EkinopsEKINOPS-PmOailEKINOPS-PmOail-MIBpmoailMesrclientEdfaTxpwrMeas1.3.6.1.4.1.20044.36.3.2.33IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL2
EkinopsEKINOPS-PmOailEKINOPS-PmOail-MIBpmoailMesrclientEdfaRxpwrMeas1.3.6.1.4.1.20044.36.3.2.34IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL1
EkinopsEKINOPS-PmOailEKINOPS-PmOail-MIBpmoailMesrlineEdfaTxpwrMeas1.3.6.1.4.1.20044.36.3.3.41IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL1
EkinopsEKINOPS-PmOailEKINOPS-PmOail-MIBpmoailMesrlineEdfaRxpwrMeas1.3.6.1.4.1.20044.36.3.3.42IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL2
EkinopsEKINOPS-PmOailhcEKINOPS-PmOailhc-MIBpmoailhcMesrclientEdfaTxpwrMeas1.3.6.1.4.1.20044.55.3.2.33IL2 Tx Power :This OID gives the transmit power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL2
EkinopsEKINOPS-PmOailhcEKINOPS-PmOailhc-MIBpmoailhcMesrclientEdfaRxpwrMeas1.3.6.1.4.1.20044.55.3.2.34IL1 Rx Power :This OID gives the receive power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL1
EkinopsEKINOPS-PmOailhcEKINOPS-PmOailhc-MIBpmoailhcMesrlineEdfaTxpwrMeas1.3.6.1.4.1.20044.55.3.3.41IL1 Tx Power :This OID gives the transmit power value of the IL1 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Tx optical power of the IL1
EkinopsEKINOPS-PmOailhcEKINOPS-PmOailhc-MIBpmoailhcMesrlineEdfaRxpwrMeas1.3.6.1.4.1.20044.55.3.3.42IL2 Rx Power :This OID gives the receive power value of the IL2 Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) <Help> This measure gives the Rx optical power of the IL2
EkinopsEKINOPS-PmoailhcsEKINOPS-Pmoailhcs-MIBpmoailhcsMesrclientMsaOutputPower1.3.6.1.4.1.20044.62.3.2.40IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2
EkinopsEKINOPS-PmoailhcsEKINOPS-Pmoailhcs-MIBpmoailhcsMesrclientMsaInputPower1.3.6.1.4.1.20044.62.3.2.39IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2
EkinopsEKINOPS-PmoailhcsEKINOPS-Pmoailhcs-MIBpmoailhcsMesrlineMsaOutputPower1.3.6.1.4.1.20044.62.3.3.56IL1 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL1
EkinopsEKINOPS-PmoailhcsEKINOPS-Pmoailhcs-MIBpmoailhcsMesrlineMsaInputPower1.3.6.1.4.1.20044.62.3.3.55IL1 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL1 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL1
EkinopsEKINOPS-PmopsEKINOPS-Pmops-MIBpmopsMesrcomaTxPower11.3.6.1.4.1.20044.30.3.2.16TX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Transmit optical power on the TX1 of the OPS A
EkinopsEKINOPS-PmopsEKINOPS-Pmops-MIBpmopsMesrcomaRxPower11.3.6.1.4.1.20044.30.3.2.18RX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Receive optical power on the RX1 of the OPS A
EkinopsEKINOPS-Pmops2dEKINOPS-Pmops2d-MIBpmops2dMesrtxPowerPortn1.3.6.1.4.1.20044.71.3.3.16.1.2Tx Power :This OID gives the transmit power value of the signal , read on the coupler output (Power=(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Transmit optical power on the TX of the OPS
EkinopsEKINOPS-Pmops2dEKINOPS-Pmops2d-MIBpmops2dMesrrxPowerPortn1.3.6.1.4.1.20044.71.3.3.24.1.2Rx Power :This OID gives the receive power value of the signal , read on the switch input (Power=(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure gives the Receive optical power on the RX of the OPS
EkinopsEKINOPS-Pmora14EKINOPS-Pmora14-MIBpmora14Mesrpump1PowerMeas1.3.6.1.4.1.20044.72.3.3.65Pump 1 Tx Power :This OID gives the Pump1 power value (Power =AV_U16/20) (Unit = mW) <Help> This measure gives the Pump1 Power value
EkinopsEKINOPS-Pmora14EKINOPS-Pmora14-MIBpmora14Mesrpump2PowerMeas1.3.6.1.4.1.20044.72.3.3.69Pump 2 Tx Power :This OID gives the Pump2 power value (Power =AV_U16/20) (Unit = mW) <Help> This measure gives the Pump2 Power value
EkinopsEKINOPS-PmOSCEKINOPS-PmOSC-MIBpmoscMesrportaTxPower1.3.6.1.4.1.20044.14.3.2.19SFP A Tx Power :This OID gives the transmit power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the port A transceiver
EkinopsEKINOPS-PmOSCEKINOPS-PmOSC-MIBpmoscMesrportaRxPower1.3.6.1.4.1.20044.14.3.2.20SFP A Rx Power :This OID gives the receive power value of the SFP A, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the port A transceiver
EkinopsEKINOPS-PmOSCEKINOPS-PmOSC-MIBpmoscMesrportbTxPower1.3.6.1.4.1.20044.14.3.3.27SFP B Tx Power :This OID gives the transmit power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Tx optical power of the port B transceiver
EkinopsEKINOPS-PmOSCEKINOPS-PmOSC-MIBpmoscMesrportbRxPower1.3.6.1.4.1.20044.14.3.3.28SFP B Rx Power :This OID gives the receive power value of the SFP B, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the port B transceiver
EkinopsEKINOPS-PmotdrEKINOPS-Pmotdr-MIBpmotdrMesrlineTxPowerPortn1.3.6.1.4.1.20044.95.3.3.32.1.2Output Power :This OID gives the output power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the output power value of the OTDR SFP
EkinopsEKINOPS-PmotdrEKINOPS-Pmotdr-MIBpmotdrMesrlineRxPowerPortn1.3.6.1.4.1.20044.95.3.3.36.1.2Input Power :This OID gives the intput power value of the OTDR SFP (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure gives the intput power value of the OTDR SFP
EkinopsEKINOPS-Rm10001wbEKINOPS-Rm10001wb-MIBrm10001wbMesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.86.3.2.256.1.2Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm10001wbEKINOPS-Rm10001wb-MIBrm10001wbMesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.86.3.2.288.1.2Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm10001wbEKINOPS-Rm10001wb-MIBrm10001wbMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.86.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm10001wbEKINOPS-Rm10001wb-MIBrm10001wbMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.86.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rm10010EKINOPS-Rm10010-MIBrm10010MesrclientNetTxPwrPortn1.3.6.1.4.1.20044.53.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Rm10010EKINOPS-Rm10010-MIBrm10010MesrclientNetRxPwrPortn1.3.6.1.4.1.20044.53.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Rm10010EKINOPS-Rm10010-MIBrm10010MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.53.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rm10010EKINOPS-Rm10010-MIBrm10010MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.53.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm10010e40EKINOPS-Rm10010e40-MIBrm10010e40MesrclientNetTxPwrPortn1.3.6.1.4.1.20044.57.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Rm10010e40EKINOPS-Rm10010e40-MIBrm10010e40MesrclientNetRxPwrPortn1.3.6.1.4.1.20044.57.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Rm10010e40EKINOPS-Rm10010e40-MIBrm10010e40MesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.57.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rm10010e40EKINOPS-Rm10010e40-MIBrm10010e40MesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.57.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm10010mpEKINOPS-Rm10010mp-MIBrm10010mpMesrclientNetTxPwrPortn1.3.6.1.4.1.20044.54.3.2.48.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Rm10010mpEKINOPS-Rm10010mp-MIBrm10010mpMesrclientNetRxPwrPortn1.3.6.1.4.1.20044.54.3.2.64.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Rm10010mpEKINOPS-Rm10010mp-MIBrm10010mpMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.54.3.3.128.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rm10010mpEKINOPS-Rm10010mp-MIBrm10010mpMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.54.3.3.80.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrclientRxPwrPortn1.3.6.1.4.1.20044.92.3.2.112.1.2Client Trscv Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the receive power value of the Client Transceiver
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.92.3.2.256.1.2Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.92.3.2.288.1.2Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrclientTxPwrPortn1.3.6.1.4.1.20044.92.3.2.80.1.2Client Trscv Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the transmit power value of the Client Transceiver
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.92.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm10010wbEKINOPS-Rm10010wb-MIBrm10010wbMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.92.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rm200frs02wbEKINOPS-Rm200frs02wb-MIBrm200frs02wbMesrclientTxCompositePwrPortn1.3.6.1.4.1.20044.105.3.2.256.1.2Client Composite Tx Power (LR4/SR4) :This OID gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite transmit power (sum of the network lanes transmit power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm200frs02wbEKINOPS-Rm200frs02wb-MIBrm200frs02wbMesrclientRxCompositePwrPortn1.3.6.1.4.1.20044.105.3.2.288.1.2Client Composite Rx Power (LR4/SR4) :This OID gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This Measure gives the composite receive power (sum of the network lanes receive power) of the Client Transceiver (LR4/SR4 only)
EkinopsEKINOPS-Rm200frs02wbEKINOPS-Rm200frs02wb-MIBrm200frs02wbMesrlineNetTxLaserOutputPwrPortn1.3.6.1.4.1.20044.105.3.3.144.1.2Current Line Trscv Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Tx Laser transmit power value of the Line Transceiver
EkinopsEKINOPS-Rm200frs02wbEKINOPS-Rm200frs02wb-MIBrm200frs02wbMesrlineNetRxInputPwrPortn1.3.6.1.4.1.20044.105.3.3.156.1.2Current Line Trscv Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = AV_S16/100) (Unit = dBm) <Help> This Measure gives the Receive power value of the Line Transceiver
EkinopsEKINOPS-Rmoac17ilwbEKINOPS-Rmoac17ilwb-MIBrmoac17ilwbMesrclientMsaOutputPower1.3.6.1.4.1.20044.110.3.2.40IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Rmoac17ilwbEKINOPS-Rmoac17ilwb-MIBrmoac17ilwbMesrclientMsaInputPower1.3.6.1.4.1.20044.110.3.2.39IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Rmoac17ilwbEKINOPS-Rmoac17ilwb-MIBrmoac17ilwbMesrlineOscTxPowerPortn1.3.6.1.4.1.20044.110.3.3.64.1.2OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver
EkinopsEKINOPS-Rmoac17ilwbEKINOPS-Rmoac17ilwb-MIBrmoac17ilwbMesrlineOscRxPowerPortn1.3.6.1.4.1.20044.110.3.3.65.1.2OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver
EkinopsEKINOPS-Rmoac17wbEKINOPS-Rmoac17wb-MIBrmoac17wbMesrclientMsaOutputPower1.3.6.1.4.1.20044.102.3.2.40IL2 MSA Tx Power :This OID indicates the output power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the output power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Rmoac17wbEKINOPS-Rmoac17wb-MIBrmoac17wbMesrclientMsaInputPower1.3.6.1.4.1.20044.102.3.2.39IL2 MSA Rx Power :This OID indicates the input power of the Mid Stage Access of the IL2 (Power =(AV_U16-32768)*0.005) (Unit = dBm) <Help> This measure indicates the input power of the Mid Stage Access of the IL2
EkinopsEKINOPS-Rmoac17wbEKINOPS-Rmoac17wb-MIBrmoac17wbMesrlineOscTxPowerPortn1.3.6.1.4.1.20044.102.3.3.64.1.2OSC Tx Power :This OID gives the transmit power value of the Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the output power of the OSC transceiver
EkinopsEKINOPS-Rmoac17wbEKINOPS-Rmoac17wb-MIBrmoac17wbMesrlineOscRxPowerPortn1.3.6.1.4.1.20044.102.3.3.65.1.2OSC Rx Power :This OID gives the receive power value of the Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV_U16)-40) (Unit = dBm) <Help> This measure indicates the input power of the OSC transceiver
Electroline Equipment Inc.ELECTROLINE-DHT-STATUSELECTROLINE-DHT-STATUS-MIBdlmRxPowerLevel1.3.6.1.4.1.5802.1.3.1.2.3.6.3The received power level at the DLM input. It's the modem RX power level added to the RF attenuator pad value.
Electroline Equipment Inc.ELECTROLINE-DHT-STATUSELECTROLINE-DHT-STATUS-MIBdlmTxPowerLevel1.3.6.1.4.1.5802.1.3.1.2.3.6.4The transmit power level at the DLM output. It's the modem TX power level minus the RF attenuator pad value.
EltexELTEX-LTP8XELTEX-LTP8Xltp8xPONChannelTxPower1.3.6.1.4.1.35265.1.22.2.1.1.9in dBm * 1000
EltexELTEX-LTP8XELTEX-LTP8Xltp8xONTStateTxPower1.3.6.1.4.1.35265.1.22.3.1.1.13in dBm * 1000 (only for NTP-2C)
EltexELTEX-LTP8XELTEX-LTP8Xltp8xONTStateRxPower1.3.6.1.4.1.35265.1.22.3.1.1.14in dBm * 1000 (only for NTP-2C)
EltexELTEX-PP4ELTEX-PP4sfpInfoRXPower1.3.6.1.4.1.35265.1.13.18.1.5Measured in uW.
EltexELTEX-PP4ELTEX-PP4sfpInfoTXPower1.3.6.1.4.1.35265.1.13.18.1.6Measured in uW.
Dell (Force10)F10-M-SERIES-CHASSISF10-M-SERIES-CHASSIS-MIBchSysPortXfpRecvPower1.3.6.1.4.1.6027.3.19.1.2.4.1.6The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-M-SERIES-CHASSISF10-M-SERIES-CHASSIS-MIBchSysPortXfpTxPower1.3.6.1.4.1.6027.3.19.1.2.4.1.8The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-S-SERIES-CHASSISF10-S-SERIES-CHASSIS-MIBchSysIfXfpTxPower1.3.6.1.4.1.6027.3.10.1.2.11.1.7The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-S-SERIES-CHASSISF10-S-SERIES-CHASSIS-MIBchSysPortXfpRecvPower1.3.6.1.4.1.6027.3.10.1.2.5.1.6The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-S-SERIES-CHASSISF10-S-SERIES-CHASSIS-MIBchSysPortXfpTxPower1.3.6.1.4.1.6027.3.10.1.2.5.1.8The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-Z-SERIES-CHASSISF10-Z-SERIES-CHASSIS-MIBchSysPortXfpRxPower1.3.6.1.4.1.6027.3.25.1.2.5.1.6The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.
Dell (Force10)F10-Z-SERIES-CHASSISF10-Z-SERIES-CHASSIS-MIBchSysPortXfpTxPower1.3.6.1.4.1.6027.3.25.1.2.5.1.8The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
BrocadeFA-EXTFA-EXT-MIBswSfpRxPower1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4This object identifies the Rx power consumption of SFP.
BrocadeFA-EXTFA-EXT-MIBswSfpTxPower1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5This object identifies the Tx power consumption of SFP.
FS.com (Fiberstore)FIBERSTOREFIBERSTORE-MIBtranspowerCurrent1.3.6.1.4.1.52642.1.37.1.10.5.1.5Transceiver currently transmit power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber.
FS.com (Fiberstore)FIBERSTOREFIBERSTORE-MIBreceivepowerCurrent1.3.6.1.4.1.52642.1.37.1.10.6.1.5Transceiver currently receive power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber.
FibrolanFIBROLAN-SFPFIBROLAN-SFP-MIBflSfpRxPower1.3.6.1.4.1.4467.1000.50.1.2.1.1Received average optical power in [uW]
FibrolanFIBROLAN-SFPFIBROLAN-SFP-MIBflSfpTxPower1.3.6.1.4.1.4467.1000.50.1.2.1.2Transmitted average optical power in [uW]
Brocade (Foundry Networks)FOUNDRY-SN-SWITCH-GROUPFOUNDRY-SN-SWITCH-GROUP-MIBsnIfOpticalLaneMonitoringTxPower1.3.6.1.4.1.1991.1.1.3.3.10.1.3This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
Brocade (Foundry Networks)FOUNDRY-SN-SWITCH-GROUPFOUNDRY-SN-SWITCH-GROUP-MIBsnIfOpticalLaneMonitoringRxPower1.3.6.1.4.1.1991.1.1.3.3.10.1.4This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
FS.com (Fiberstore)FS-AC-MGMTFS-AC-MGMT-MIBfsApCurTxPower1.3.6.1.4.1.52642.1.1.10.2.56.2.1.2.1.17Current tx power, mw.
FS.com (Fiberstore)FS-AC-MGMTFS-AC-MGMT-MIBfsApTxPower1.3.6.1.4.1.52642.1.1.10.2.56.2.1.2.1.3Tx power, 1%.
FS.com (Fiberstore)FS-FIBERFS-FIBER-MIBfsFiberRXpowerInteger1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.76The integer of Rx power of the Fiber module insered into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Rx power value is -10000(means that the value is invalid). Added by Observium Developers.
FS.com (Fiberstore)FS-FIBERFS-FIBER-MIBfsFiberChannel1RXpowerInteger1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.77The integer part of Rx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -10000(means the value is invalid). Added by Observium Developers.
FS.com (Fiberstore)FS-FIBERFS-FIBER-MIBfsFiberTXpowerInteger1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.81The integer part of Tx power of the Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Tx power value is -10000(means that the value is invalid). Added by Observium Developers.
FS.com (Fiberstore)FS-FIBERFS-FIBER-MIBfsFiberChannel1TXpowerInteger1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.82The integer part of Tx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -10000(means the value is invalid). Added by Observium Developers.
FS.com (Fiberstore)FS-NMS-IFFS-NMS-IF-MIBtxPower31.3.6.1.4.1.52642.9.63.1.7.1.11The tx 3 power of optical module. The unit is 1DBm.
FS.com (Fiberstore)FS-NMS-IFFS-NMS-IF-MIBrxPower31.3.6.1.4.1.52642.9.63.1.7.1.12The rx 3 power of optical module. The unit is 1DBm.
FS.com (Fiberstore)FS-NMS-OPTICAL-PORTFS-NMS-OPTICAL-PORT-MIBopIfRxPowerCurr1.3.6.1.4.1.52642.9.183.1.1.5A unique value for each optical interface, that means optical current receive power value.
FS.com (Fiberstore)FS-NMS-OPTICAL-PORTFS-NMS-OPTICAL-PORT-MIBopIfTxPowerCurr1.3.6.1.4.1.52642.9.183.1.1.8A unique value for each optical interface, that means optical current sending power value.
FS.comFS-SWITCHFS-SWITCH-MIBtranspowerCurrent1.3.6.1.4.1.27975.37.1.10.5.1.5Transceiver currently transmit power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber.
FS.comFS-SWITCHFS-SWITCH-MIBreceivepowerCurrent1.3.6.1.4.1.27975.37.1.10.6.1.5Transceiver currently receive power value, unit is dBm. Display 4 vlaue in the case of 40G/100G fiber.
ADVA Optical NetworkingFspR7FspR7-MIBopticalIfDiagInputPower1.3.6.1.4.1.2544.1.11.2.4.3.5.1.3The optical input power of a transmitter in dBm, measured in the range of -x to +y dBm (TBD). It is only valid when there is no loss of signal at the input, in which case a value of -65535 is returned. A value of -65535 also indicates that OIP is not available. When out of range, -65534 indicates that the OIP is outside the maximum value and -65533 for outside the minimum value.
Fujitsu LimitedFSS-OPTICAL-CHANNEL-INTERFACEFSS-OPTICAL-CHANNEL-INTERFACEochTx-target-power1.3.6.1.4.1.211.1.24.12.700.200.1.1.7Transmit output power setting.
MicrosensG6-SFPG6-SFP-MIBinformationTxPower1.3.6.1.4.1.3181.10.6.1.34.100.1.18Indicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
MicrosensG6-SFPG6-SFP-MIBinformationRxPower1.3.6.1.4.1.3181.10.6.1.34.100.1.19Indicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
Gainspeed, Inc.GAINSPEED-ENVMONGAINSPEED-ENVMON-MIBgsemUplinkOpticsRxPower1.3.6.1.4.1.44886.10.10.1.4.1.1.2optics receive-power value of one uplink port.
Gainspeed, Inc.GAINSPEED-ENVMONGAINSPEED-ENVMON-MIBgsemUplinkOpticsTxPower1.3.6.1.4.1.44886.10.10.1.4.1.1.3optics transmit-power value of one uplink port.
Trango Networks, LLCGIGA-PLUSGIGA-PLUS-MIBrfPower1.3.6.1.4.1.5454.1.80.3.4.1Set/Display TX power. SNMPc does not support setting and displaying float value.
GCOM / GreentechGPONGPON-MIBponRXPower1.3.6.1.4.1.13464.1.11.3.1.1.24unit: dBm
GCOM / GreentechGPONGPON-MIBponTXPower1.3.6.1.4.1.13464.1.11.3.1.1.27unit: dBm
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMGUD-CCDM-MIBioCardFiberTxPower1.3.6.1.4.1.32828.3.257.10.2.3.1005.1.3TX power for each fiber io card port.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMGUD-CCDM-MIBioCardFiberRxPower1.3.6.1.4.1.32828.3.257.10.2.3.1005.1.4RX power for each fiber io card port.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCONGUD-CCDMCON-MIBsfpTxPower1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.20SFP TX power [uW] of the device.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCONGUD-CCDMCON-MIBsfpTxPower21.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.22SFP TX power [uW] of the second transmission line of the device.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCONGUD-CCDMCON-MIBsfpRxPower1.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.23SFP RX power [uW] of the device.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCONGUD-CCDMCON-MIBsfpRxPower21.3.6.1.4.1.32828.3.257.10.1.1.2.3.1000.1.25SFP RX power [uW] of the second transmission line of the device.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCPUGUD-CCDMCPU-MIBsfpTxPower1.3.6.1.4.1.32828.3.257.10.1.2.2.3.1000.1.21SFP TX power [uW] of the device.
Guntermann & Drunck GmbH SystementwicklungGUD-CCDMCPUGUD-CCDMCPU-MIBsfpRxPower1.3.6.1.4.1.32828.3.257.10.1.2.2.3.1000.1.22SFP RX power [uW] of the device.
HuaweiH3C-TRANSCEIVER-INFOH3C-TRANSCEIVER-INFO-MIBh3cTransceiverCurRXPower1.3.6.1.4.1.2011.10.2.70.1.1.1.12Indicating the current received power . The unit is in hundredths of dBM.
HuaweiH3C-TRANSCEIVER-INFOH3C-TRANSCEIVER-INFO-MIBh3cTransceiverCurTXPower1.3.6.1.4.1.2011.10.2.70.1.1.1.9Indicating the current transmitted power . The unit is in hundredths of dBM.
H3CHH3C-3GMODEMHH3C-3GMODEM-MIBhh3cLteTxPower1.3.6.1.4.1.25506.2.98.1.5.1.1.4Transmit power, 0x8000 means invalid.
H3CHH3C-TRANSCEIVER-INFOHH3C-TRANSCEIVER-INFO-MIBhh3cTransceiverChannelCurTXPower1.3.6.1.4.1.25506.2.70.1.2.1.2Indicating the current transmission power. The unit is in hundredths of dBM.
H3CHH3C-TRANSCEIVER-INFOHH3C-TRANSCEIVER-INFO-MIBhh3cTransceiverChannelCurRXPower1.3.6.1.4.1.25506.2.70.1.2.1.3Indicating the current received power. The unit is in hundredths of dBM.
HirschmannHIRSCHMANN-BAT-F-SINGLEHIRSCHMANN-BAT-F-SINGLE-MIBhmStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.248.32.16.10.1.51.11.1.14No description published.
HirschmannHIRSCHMANN-BAT-F-SINGLEHIRSCHMANN-BAT-F-SINGLE-MIBhmStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.248.32.16.10.1.51.11.1.15No description published.
HirschmannHIRSCHMANN-BAT-RAIL-SINGLEHIRSCHMANN-BAT-RAIL-SINGLE-MIBhmStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.248.32.16.11.1.51.11.1.14No description published.
HirschmannHIRSCHMANN-BAT-RAIL-SINGLEHIRSCHMANN-BAT-RAIL-SINGLE-MIBhmStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.248.32.16.11.1.51.11.1.15No description published.
HirschmannHIRSCHMANN-BAT300RAILHIRSCHMANN-BAT300RAIL-MIBhmStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.248.32.16.40.1.51.11.1.14No description published.
HirschmannHIRSCHMANN-BAT300RAILHIRSCHMANN-BAT300RAIL-MIBhmStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.248.32.16.40.1.51.11.1.15No description published.
HirschmannHIRSCHMANN-BAT54CLIENTHIRSCHMANN-BAT54CLIENT-MIBhmStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.248.32.16.9.1.51.11.1.14No description published.
HirschmannHIRSCHMANN-BAT54CLIENTHIRSCHMANN-BAT54CLIENT-MIBhmStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.248.32.16.9.1.51.11.1.15No description published.
HirschmannHIRSCHMANN-BAT54RAILHIRSCHMANN-BAT54RAIL-MIBhmStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.248.32.16.8.1.51.11.1.14No description published.
HirschmannHIRSCHMANN-BAT54RAILHIRSCHMANN-BAT54RAIL-MIBhmStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.248.32.16.8.1.51.11.1.15No description published.
HirschmannHM2-DEVMGMTHM2-DEVMGMT-MIBhm2SfpCurrentTxPowerdBm1.3.6.1.4.1.248.11.10.1.7.2.1.5The SFP's internally measured Tx Power in units of dBm. (ASCII representation of a floating point number). - if not supported.
HirschmannHM2-DEVMGMTHM2-DEVMGMT-MIBhm2SfpCurrentRxPowerdBm1.3.6.1.4.1.248.11.10.1.7.2.1.6The SFP's internally measured Rx Power in units of dBm. (ASCII representation of a floating point number). - if not supported.
HirschmannHMIT-SW-PORTMGR-DDMIHMIT-SW-PORTMGR-DDMI-MIBportDDMITxPower1.3.6.1.4.1.248.100.1.6.3.1.13.6.1.31The tx power measured by the transceiver itself.
HirschmannHMPRIV-MGMT-SNMPHMPRIV-MGMT-SNMP-MIBhmSfpTxPower1.3.6.1.4.1.248.14.1.1.13.1.13The SFP's internally measured Tx Power in units of milliWatts. (ASCII representation of floating point number).
HirschmannHMPRIV-MGMT-SNMPHMPRIV-MGMT-SNMP-MIBhmSfpRxPower1.3.6.1.4.1.248.14.1.1.13.1.14The SFP's internally measured Rx Power in units of milliWatts. (ASCII representation of floating point number).
HPHP-ICF-TRANSCEIVERHP-ICF-TRANSCEIVER-MIBhpicfXcvrTxPower1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14This is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
HPHPN-ICF-TRANSCEIVER-INFOHPN-ICF-TRANSCEIVER-INFO-MIBhpnicfTransceiverChannelCurTXPower1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.2Indicating the current transmission power. The unit is in hundredths of dBM.
HPHPN-ICF-TRANSCEIVER-INFOHPN-ICF-TRANSCEIVER-INFO-MIBhpnicfTransceiverChannelCurRXPower1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.3Indicating the current received power. The unit is in hundredths of dBM.
HuaweiHUAWEI-ENTITY-EXTENTHUAWEI-ENTITY-EXTENT-MIBhwEntityOpticalLaneRxPower1.3.6.1.4.1.2011.5.25.31.1.1.3.1.32The receive power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 114,32,-90,-228)
HuaweiHUAWEI-ENTITY-EXTENTHUAWEI-ENTITY-EXTENT-MIBhwEntityOpticalLaneTxPower1.3.6.1.4.1.2011.5.25.31.1.1.3.1.33The transmit power of the QSFP or CFP optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times (e.g., 94,-39,33,-58)
HuaweiHUAWEI-ENTITY-EXTENTHUAWEI-ENTITY-EXTENT-MIBhwEntityOpticalRxPower1.3.6.1.4.1.2011.5.25.31.1.1.3.1.8The receive power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times
HuaweiHUAWEI-ENTITY-EXTENTHUAWEI-ENTITY-EXTENT-MIBhwEntityOpticalTxPower1.3.6.1.4.1.2011.5.25.31.1.1.3.1.9The transmit power of the optical module. Unit: dBm. the value is expanded 100 times,so the real value should be reduced 100 times
HuaweiHUAWEI-ENVIRONMENTHUAWEI-ENVIRONMENT-MIBhwOTOpticalOutputPowerValue1.3.6.1.4.1.2011.6.1.1.7.1.21This is the power of the only channel for the single-channel optical transmitter. This is the power of channel 0 for the dual-channel optical transmitter. Its unit is 0.01dbm. invalid: 0x7fffffff.
HuaweiHUAWEI-ENVIRONMENTHUAWEI-ENVIRONMENT-MIBhwOROpticalCH1PowerValue1.3.6.1.4.1.2011.6.1.1.7.1.32This is the power of channel 1 for the dual-channel optical receiver. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff.
HuaweiHUAWEI-ENVIRONMENTHUAWEI-ENVIRONMENT-MIBhwOTOpticalOutputCH1PowerValue1.3.6.1.4.1.2011.6.1.1.7.1.39This is the power of channel 1 for the dual-channel optical transmitter. Its unit is dbm,its real accuracy is 0.01. SNMP uses it which has been enlarged 100 by host. user uses it which has been lessened 100 by SNMP. invalid: 0x7fffffff.
HuaweiHUAWEI-ETHERNET-OPTICMODULEHUAWEI-ETHERNET-OPTICMODULE-MIBhwOpticsTxPower1.3.6.1.4.1.2011.5.14.6.4.1.4Transmitted power. Invalid value: 2147483647, an invalid value is returned if the optical module is unavailable or is not supported. Unit: 0.000001dBm
HuaweiHUAWEI-ETHERNET-OPTICMODULEHUAWEI-ETHERNET-OPTICMODULE-MIBhwOpticsRxPower1.3.6.1.4.1.2011.5.14.6.4.1.5Received power. Invalid value: 2147483647, an invalid value is returned if the optical module is unavailable or is not supported. Unit: 0.000001dBm
HuaweiHUAWEI-GONUHUAWEI-GONU-MIBhwGonuTxPower1.3.6.1.4.1.2011.5.104.1.1.1.1.8The MDU TX power. Unit: 1/100 dBm
HuaweiHUAWEI-GONUHUAWEI-GONU-MIBhwGonuRxPower1.3.6.1.4.1.2011.5.104.1.1.1.1.9The MDU RX power. Unit: 1/100 dBm
HuaweiHUAWEI-GONUHUAWEI-GONU-MIBhwGonuOltPonTxPower1.3.6.1.4.1.2011.5.104.1.9.1.1.2OLT PON TX power. Unit: 1/100 dBm
HuaweiHUAWEI-GPONHUAWEI-GPON-MIBhwGponOntCatvTxPower1.3.6.1.4.1.2011.5.100.1.1.1.25.1.7This object indicates the Tx power of ONT CATV port. Unit: 0.001dBmV Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
HuaweiHUAWEI-GPONHUAWEI-GPON-MIBhwGponOpticsTxPower1.3.6.1.4.1.2011.5.100.1.1.1.51.1.4Optics send power,units of 0.01dBm.
HuaweiHUAWEI-GPONHUAWEI-GPON-MIBhwGponOntOpticsOltRxOntPower1.3.6.1.4.1.2011.5.100.1.1.1.53.1.6The ONT optical power received on the OLT, unit dBm. The relationship between the actual value and the value get from this leaf node is as follows, Actual value = ((Node value - 10000) / 100)
HuaweiHUAWEI-XPONHUAWEI-XPON-MIBhwEponOntOpticalDdmOltRxOntPower1.3.6.1.4.1.2011.6.128.1.1.2.104.1.1The ONT optical power received on the OLT, unit dBm. The relationship between the actual value and the value get from this leaf node is as follows, Actual value = ((Node value - 10000) / 100)
Icotera A/SICOTERA-I6400-SERIESICOTERA-I6400-SERIEStransceiverDdmTxPower1.3.6.1.4.1.29865.11.3.1.3.2Measured TX output power. Represented in increments of 1/10000 mW.
Icotera A/SICOTERA-I6400-SERIESICOTERA-I6400-SERIEStransceiverDdmRxPower1.3.6.1.4.1.29865.11.3.1.3.3Measured RX received optical power. Represented in increments of 1/10000 mW.
ZyxelIES5206IES5206-MIBtransceiverPerOntRxPower1.3.6.1.4.1.890.1.5.13.13.31.14.4.1.2Transceiver high alarm threshold. The unit for RX power is dbm The value neg inf represents negative infinit(0mW) The value N/A represents not applicable.
ZyxelIES5206IES5206-MIBgeDdmiTxPowerdBm1.3.6.1.4.1.890.1.5.13.13.4.4.1.18Measured TX output power in 10^(-4) dBm.
IPIIPI-CMM-CHASSISIPI-CMM-CHASSIS-MIBcmmTransTxPower1.3.6.1.4.1.36673.100.1.2.3.1.17Measured TX output power in Channel of transceiver. '-100000' value represents no power. '-100001' indicates unavailable. '-100002' indicates not-applicable.
IPIIPI-CMM-CHASSISIPI-CMM-CHASSIS-MIBcmmTransRxPower1.3.6.1.4.1.36673.100.1.2.3.1.22Measured RX input power in Channel of transceiver '-100000' value represents no power in the transceiver. '-100001' indicates unavailable. '-100002' indicates not-applicable.
Iskratel, Ltd.ISKRATEL-MSANISKRATEL-MSAN-MIBmsanSfpDiagnosticsTxPowerCurrent1.3.6.1.4.1.1332.1.1.5.3.32.3.1.12Current SFP module transmitted optical output power value in [mW]. If diagnostic is not supported for SFP module then current transmitted optical output power is set on not supported value(-1).
Iskratel, Ltd.ISKRATEL-MSANISKRATEL-MSAN-MIBmsanSfpDiagnosticsRxPowerCurrent1.3.6.1.4.1.1332.1.1.5.3.32.3.1.15Current SFP module received optical input power value in [mW]. If diagnostic is not supported for SFP module then current received optical input power is set on not supported value(-1).
KorenixJetnet4510Jetnet4510portSfpDdmRxPowerRange1.3.6.1.4.1.24062.2.2.3.3.2.2.1.10The range of SFP Receiveed Power of port.
KorenixJetnet4510Jetnet4510portSfpDdmTxPowerCurrent1.3.6.1.4.1.24062.2.2.3.3.2.2.1.7The current SFP Transmitted Power of port.
KorenixJetnet4510Jetnet4510portSfpDdmTxPowerRange1.3.6.1.4.1.24062.2.2.3.3.2.2.1.8The range of SFP Transmitted Power of port.
KorenixJetnet4510Jetnet4510portSfpDdmRxPowerCurrent1.3.6.1.4.1.24062.2.2.3.3.2.2.1.9The current SFP Receiveed Power of port.
KorenixJetnet5010GJetnet5010GportSfpDdmRxPowerRange1.3.6.1.4.1.24062.2.2.1.3.2.2.1.10The range of SFP Receiveed Power of port.
KorenixJetnet5010GJetnet5010GportSfpDdmTxPowerCurrent1.3.6.1.4.1.24062.2.2.1.3.2.2.1.7The current SFP Transmitted Power of port.
KorenixJetnet5010GJetnet5010GportSfpDdmTxPowerRange1.3.6.1.4.1.24062.2.2.1.3.2.2.1.8The range of SFP Transmitted Power of port.
KorenixJetnet5010GJetnet5010GportSfpDdmRxPowerCurrent1.3.6.1.4.1.24062.2.2.1.3.2.2.1.9The current SFP Receiveed Power of port.
KorenixJetnet5310GJetnet5310GportSfpDdmRxPowerRange1.3.6.1.4.1.24062.2.3.9.3.2.2.1.10The range of SFP Receiveed Power of port.
KorenixJetnet5310GJetnet5310GportSfpDdmTxPowerCurrent1.3.6.1.4.1.24062.2.3.9.3.2.2.1.7The current SFP Transmitted Power of port.
KorenixJetnet5310GJetnet5310GportSfpDdmTxPowerRange1.3.6.1.4.1.24062.2.3.9.3.2.2.1.8The range of SFP Transmitted Power of port.
KorenixJetnet5310GJetnet5310GportSfpDdmRxPowerCurrent1.3.6.1.4.1.24062.2.3.9.3.2.2.1.9The current SFP Receiveed Power of port.
JuniperJUNIPER-DOMJUNIPER-DOM-MIBjnxDomCurrentRxLaserPower1.3.6.1.4.1.2636.3.60.1.1.1.1.5Receiver laser power.
JuniperJUNIPER-DOMJUNIPER-DOM-MIBjnxDomCurrentTxLaserOutputPower1.3.6.1.4.1.2636.3.60.1.1.1.1.7Transmitter laser output power.
JuniperJUNIPER-DOMJUNIPER-DOM-MIBjnxDomCurrentLaneRxLaserPower1.3.6.1.4.1.2636.3.60.1.2.1.1.6Receiver laser power on a particular Lane of a SFF physcial interface.
JuniperJUNIPER-DOMJUNIPER-DOM-MIBjnxDomCurrentLaneTxLaserOutputPower1.3.6.1.4.1.2636.3.60.1.2.1.1.8Transmitter laser power on a particular Lane of a SFF physcial interface.
Katron Technologies Inc.KGD-802-B_MIBKGD-802-B_MIBTX_Power1.3.6.1.4.1.867.65.1.1.1.10Measured TX output power(uW). dBm = -30 dBm + log10( N ) x 10
DeltanetLAMBDATRAILLAMBDATRAIL-MIBportClientTxPower1.3.6.1.4.1.35616.2.1.1.12.1.15unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available
DeltanetLAMBDATRAILLAMBDATRAIL-MIBportClientRxPower1.3.6.1.4.1.35616.2.1.1.12.1.16unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available
DeltanetLAMBDATRAILLAMBDATRAIL-MIBportLineTxPower1.3.6.1.4.1.35616.2.1.1.12.1.8unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available
DeltanetLAMBDATRAILLAMBDATRAIL-MIBportLineRxPower1.3.6.1.4.1.35616.2.1.1.12.1.9unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sMgmtSfpTxPower1.3.6.1.4.1.35616.5.1.26.1.13The SFP transmit power of the port. If the SFP is removed, the value is -1.
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sMgmtSfpRxPower1.3.6.1.4.1.35616.5.1.26.1.14The SFP receive power of the port. If the SFP is removed, the value is -1.
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sLineTxPower1.3.6.1.4.1.35616.5.3.1.1.13The line SFP transmit power of the port. If the line SFP is not plugged in, the object should contain the value of -1.
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sLineRxPower1.3.6.1.4.1.35616.5.3.1.1.14The line SFP receive power of the port. If the line SFP is not plugged in, the object should contain the value of -1.
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sClientTxPower1.3.6.1.4.1.35616.5.3.1.1.26The client SFP transmit power of the port. If the client SFP is not plugged in, the object should contain the value of -1.
DeltanetLambdatrail2sLambdatrail2s-MIBlt2sClientRxPower1.3.6.1.4.1.35616.5.3.1.1.27The client SFP receive power of the port. If the client SFP is not plugged in, the object should contain the value of -1.
LANCOM SystemsLCOSLCOS-MIBlcsStatusEthernetPortsSfpPortsEntryTxPower1.3.6.1.4.1.2356.11.1.51.11.1.14No description published.
LANCOM SystemsLCOSLCOS-MIBlcsStatusEthernetPortsSfpPortsEntryRxPower1.3.6.1.4.1.2356.11.1.51.11.1.15No description published.
LuxN, Inc.LUXNLUXN-MIBdmmPortRxPower1.3.6.1.4.1.4253.1.28.3.1.10Receive power reported by port SFP.
LuxN, Inc.LUXNLUXN-MIBoscPortRxPower1.3.6.1.4.1.4253.1.31.3.1.7Receive power reported by port SFP.
CiscoME1200-DDMIME1200-DDMI-MIBme1200DdmiStatusInterfaceA2CurrentTxPower1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1018Current Tx power in mV.
CiscoME1200-DDMIME1200-DDMI-MIBme1200DdmiStatusInterfaceA2CurrentRxPower1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1023Current Rx power in mV.
MicrosensMICROSENS-CWDM8MICROSENS-CWDM8-MIBlineModuleTransmittedPower1.3.6.1.4.1.3181.6.4.4.1.18This entry describes the transmitter optical output power in micro watt.
MicrosensMICROSENS-CWDM8MICROSENS-CWDM8-MIBlineModuleReceivedPower1.3.6.1.4.1.3181.6.4.4.1.19This entry describes the transmitter optical received power in micro watt.
MicrosensMICROSENS-CWDM8MICROSENS-CWDM8-MIBlineIfWestLinkRcvPower1.3.6.1.4.1.3181.6.4.6.1.8This entry describes the west-link receive power of the interface module in micro watts.
MicrosensMICROSENS-CWDM8MICROSENS-CWDM8-MIBlineIfEastLinkRcvPower1.3.6.1.4.1.3181.6.4.6.1.9This entry describes the east-link receive power of the interface module in micro watts.
Mimosa NetworksMIMOSA-NETWORKS-BFIVEMIMOSA-NETWORKS-BFIVE-MIBmimosaTxPower1.3.6.1.4.1.43356.2.1.2.6.1.1.2Specifies the transmit power of the given RF chain. A value of -8 means this particular TxChain is not a valid entry.
Mimosa NetworksMIMOSA-NETWORKS-BFIVEMIMOSA-NETWORKS-BFIVE-MIBmimosaRxPower1.3.6.1.4.1.43356.2.1.2.6.1.1.3Specifies the receive power of the given RF chain. A value of -100 means this particular RxChain is not a valid entry (SNR must be -100).
Mimosa NetworksMIMOSA-NETWORKS-BFIVEMIMOSA-NETWORKS-BFIVE-MIBmimosaChannelTxPower1.3.6.1.4.1.43356.2.1.2.6.3.1.4Specifies the transmit power level on the channel. If Channel Width is set to 1xN MHz, Channel 2 is not be used. In Frequency Diversity mode, Power 1 and Power 2 represent transmit power on the local and remote sides, respectively.
Mimosa NetworksMIMOSA-NETWORKS-BFIVEMIMOSA-NETWORKS-BFIVE-MIBmimosaTotalTxPower1.3.6.1.4.1.43356.2.1.2.6.5The total transmit power for all the channels on the Mimosa device.
Mimosa NetworksMIMOSA-NETWORKS-BFIVEMIMOSA-NETWORKS-BFIVE-MIBmimosaTotalRxPower1.3.6.1.4.1.43356.2.1.2.6.6The total receive power for all the channels on the Mimosa device.
Mimosa NetworksMIMOSA-NETWORKS-PTMPMIMOSA-NETWORKS-PTMP-MIBmimosaPtmpChPwrTxPowerCur1.3.6.1.4.1.43356.2.1.2.9.3.3.1.10Describes the current transmit power level. The allowed options are determined by a combination of country and chosen frequency. Measured in dBm
MoxaMOXA-EDSG508EMOXA-EDSG508E-MIBfiberTxPower1.3.6.1.4.1.8691.7.69.1.10.11.1.7The fiber TX power of monitor function
MoxaMOXA-EDSG508EMOXA-EDSG508E-MIBfiberRxPower1.3.6.1.4.1.8691.7.69.1.10.11.1.9The fiber RX power of monitor function
MoxaMOXA-EDSG512E8POEMOXA-EDSG512E8POE-MIBfiberTxPower1.3.6.1.4.1.8691.7.108.1.10.11.1.7The fiber TX power of monitor function
MoxaMOXA-EDSG512E8POEMOXA-EDSG512E8POE-MIBfiberRxPower1.3.6.1.4.1.8691.7.108.1.10.11.1.9The fiber RX power of monitor function
MoxaMOXA-EDSP506EMOXA-EDSP506E-MIBfiberTxPower1.3.6.1.4.1.8691.7.162.1.10.11.1.7The fiber TX power of monitor function
MoxaMOXA-EDSP506EMOXA-EDSP506E-MIBfiberRxPower1.3.6.1.4.1.8691.7.162.1.10.11.1.9The fiber RX power of monitor function
MoxaMOXA-EDSP510A8POEMOXA-EDSP510A8POE-MIBsfpTxPower1.3.6.1.4.1.8691.7.86.1.10.7.1.5The SPF TX power of monitor function
MoxaMOXA-EDSP510A8POEMOXA-EDSP510A8POE-MIBsfpRXPower1.3.6.1.4.1.8691.7.86.1.10.7.1.6The SPF RX power of monitor function
MoxaMOXA-ICSG7826AMOXA-ICSG7826A-MIBsfpTxPower1.3.6.1.4.1.8691.7.99.1.10.7.1.5The SFP TX power(dBm) of monitor function
MoxaMOXA-ICSG7826AMOXA-ICSG7826A-MIBsfpRxPower1.3.6.1.4.1.8691.7.99.1.10.7.1.6The SFP RX power(dBm) of monitor function
MoxaMOXA-IKS6726AMOXA-IKS6726A-MIBsfpTxPower1.3.6.1.4.1.8691.7.116.1.10.7.1.5The SFP TX power(dBm) of monitor function
MoxaMOXA-IKS6726AMOXA-IKS6726A-MIBsfpRxPower1.3.6.1.4.1.8691.7.116.1.10.7.1.6The SFP RX power(dBm) of monitor function
MicrosensMS-SWITCH30MS-SWITCH30-MIBsfpTxPower1.3.6.1.4.1.3181.10.3.9.10.1.13This entry describes the optical transmit power of the sfp in multiple of 0.1 uW.
MicrosensMS-SWITCH30MS-SWITCH30-MIBsfpRxPower1.3.6.1.4.1.3181.10.3.9.10.1.14This entry describes the ooptical receive power of the sfp in multiple of 0.1 uW.
NAGTECH LLCNAGNAG-MIBddmDiagnosisRXPower1.3.6.1.4.1.57206.7.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
NAGTECH LLCNAGNAG-MIBddmDiagnosisTXPower1.3.6.1.4.1.57206.7.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
NATEKS Ltd.NATEKSNATEKS-MIBsfpDDMRxInputmW1.3.6.1.4.1.4249.2.5.9.2.1.7Measured RX received optical power from 0 to 6.5535 mW.
NATEKS Ltd.NATEKSNATEKS-MIBsfpDDMRxInputdBm1.3.6.1.4.1.4249.2.5.9.2.1.8Measured RX received optical power from -40 to +8.2 dBm.
MRV CommunicationsNBS-CMMCNBS-CMMC-MIBnbsCmmcPortTxPowerLevel1.3.6.1.4.1.629.200.8.1.1.65This object indicates whether this port has a problem with its transmitter power. If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1). If Digital Diagnostics indicate TxPower is below the low Alarm Threshold, this value should be lowAlarm(2). If Digital Diagnostics indicate TxPower is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3). If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4). If Digital Diagnostics indicate TxPower is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),. If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6). The related object nbsCmmcPortTxPower indicates what the current TxPower is.
MRV CommunicationsNBS-CMMCNBS-CMMC-MIBnbsCmmcPortRxPowerLevel1.3.6.1.4.1.629.200.8.1.1.66This object indicates whether this port has a problem with the power of its received signal. If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1). If Digital Diagnostics indicate RxPower is below the low Alarm Threshold, this value should be lowAlarm(2). If Digital Diagnostics indicate RxPower is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3). If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4). If Digital Diagnostics indicate RxPower is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),. If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6). The related object nbsCmmcPortRxPower indicates what the current RxPower is.
MRV CommunicationsNBS-OSANBS-OSA-MIBnbsOsaSpectrumRxPowerOper1.3.6.1.4.1.629.207.2.2.1.5The last known signal strength, in millidecibels (mdBm), of this channel.
MRV CommunicationsNBS-OSANBS-OSA-MIBnbsOsaChannelRxPowerOper1.3.6.1.4.1.629.207.3.2.1.8The last known signal strength, in millidecibels (mdBm), of this channel. Not supported value: -100001
MRV CommunicationsNBS-SFFNBS-SFF-MIBnbsSffDiagsTxPower1.3.6.1.4.1.629.204.1.3.1.1.35Measured TX output power in the units of dBm.
MRV CommunicationsNBS-SFFNBS-SFF-MIBnbsSffDiagsRxPower1.3.6.1.4.1.629.204.1.3.1.1.40Measured received optical power. Received power, RX_PWR, is given in uW by the following equation: Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD 4 (16 bit unsigned integer) + Rx_PWR(3) * Rx_PWR AD 3 (16 bit unsigned integer) + Rx_PWR(2) * Rx_PWR AD 2 (16 bit unsigned integer) + Rx_PWR(1) * Rx_PWR AD (16 bit unsigned integer) + Rx_PWR(0)
MRV CommunicationsNBS-SIGCONDNBS-SIGCOND-MIBnbsSigCondPortRxPower1.3.6.1.4.1.629.227.40.2.1.2Measured receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
MRV CommunicationsNBS-SIGCONDNBS-SIGCOND-MIBnbsSigCondPortTxPower1.3.6.1.4.1.629.227.40.2.1.3Measured transmitter power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000
MRV CommunicationsNBS-SIGCONDNBS-SIGCOND-MIBnbsSigCondChannelRxPower1.3.6.1.4.1.629.227.50.2.1.11The dynamically measured or calculated receive signal strength
MRV CommunicationsNBS-SIGCONDNBS-SIGCOND-MIBnbsSigCondChannelTxPower1.3.6.1.4.1.629.227.50.2.1.12The dynamically measured or calculated transmit signal strength
MRV CommunicationsNBS-SIGLANENBS-SIGLANE-MIBnbsSigLaneLaneTxPowerLevel1.3.6.1.4.1.629.236.20.1.1.20This object indicates the status of this lane's measured received power, reported in nbsSigLaneLaneTxPower: notSupported(1), if (nbsSigLaneLaneTxPower = 0x80000000); lowAlarm(2), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMin; lowWarning(3), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMin and nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerUserMin; ok(4), if nbsSigLaneLaneTxPower is within thresholds; highWarning(5), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMax and nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerUserMax; highAlarm(6), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMax
MRV CommunicationsNBS-SIGLANENBS-SIGLANE-MIBnbsSigLaneLaneTxPower1.3.6.1.4.1.629.236.20.1.1.21The output power (in milli dBm) of this lane. Not supported value: 0x80000000
MRV CommunicationsNBS-SIGLANENBS-SIGLANE-MIBnbsSigLaneLaneRxPowerLevel1.3.6.1.4.1.629.236.20.1.1.30This object indicates the status of this lane's measured received power, reported in nbsSigLaneLaneRxPower: notSupported(1), if (nbsSigLaneLaneRxPower = 0x80000000); lowAlarm(2), if nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerVendorMin; lowWarning(3), if nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerVendorMin and nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerUserMin; ok(4), if nbsSigLaneLaneRxPower is within thresholds; highWarning(5), if nbsSigLaneLaneRxPower < nbsSigLanePortRxPowerVendorMax and nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerUserMax; highAlarm(6), if nbsSigLaneLaneRxPower > nbsSigLanePortRxPowerVendorMax
MRV CommunicationsNBS-SIGLANENBS-SIGLANE-MIBnbsSigLaneLaneRxPower1.3.6.1.4.1.629.236.20.1.1.31The received optical power (in milli dBm) of this lane. Not supported value: 0x80000000
Aginode (Nexans)NEXANS-BMNEXANS-BM-MIBsfpDiagTxOutputPower1.3.6.1.4.1.266.20.5.1.1.17The current transmitter output power of the SFP module in microwatt.
Aginode (Nexans)NEXANS-BMNEXANS-BM-MIBsfpDiagTxOutputPowerDbm1.3.6.1.4.1.266.20.5.1.1.18The current transmitter output power of the SFP module in dbm.
Aginode (Nexans)NEXANS-BMNEXANS-BM-MIBsfpDiagRxIntputPower1.3.6.1.4.1.266.20.5.1.1.19The current receiver input power of the SFP module in microwatt.
Aginode (Nexans)NEXANS-BMNEXANS-BM-MIBsfpDiagRxInputPowerDbm1.3.6.1.4.1.266.20.5.1.1.20The current receiver input power of the SFP module in dbm.
GCOM / GreentechNGPONNGPON-MIBontRXPower1.3.6.1.4.1.13464.1.14.2.4.1.4.1.5ont received optical power(dBm).
GCOM / GreentechNGPONNGPON-MIBontTXPower1.3.6.1.4.1.13464.1.14.2.4.1.4.1.6ont mean optical launch power(dBm).
Pacific Broadband NetworksNMS-EPON-OLT-PON-EXTNMS-EPON-OLT-PON-EXTtxPower1.3.6.1.4.1.11606.10.101.107.1.3The tx power of optical module. The unit is 0.1DBm.
Pacific Broadband NetworksNMS-EPON-OLT-PON-EXTNMS-EPON-OLT-PON-EXTrxPower1.3.6.1.4.1.11606.10.101.108.1.3The rx power of optical module. The unit is 0.1DBm.
Pacific Broadband NetworksNMS-EPON-ONUNMS-EPON-ONUrxPower1.3.6.1.4.1.11606.10.101.10.31.1.2Onu CATV module rx power. Unit is 0.1 DBm.
Pacific Broadband NetworksNMS-EPON-ONUNMS-EPON-ONUopModuleRxPower1.3.6.1.4.1.11606.10.101.10.5.1.5ONU PON port optical receive power. Unit is 0.1dB.
Pacific Broadband NetworksNMS-EPON-ONUNMS-EPON-ONUopModuleTxPower1.3.6.1.4.1.11606.10.101.10.5.1.6ONU PON port optical send power. Unit is 0.1dB.
Pacific Broadband NetworksNMS-GPONNMS-GPON-MIBgponOltPonPortOpticalParameterTxPower1.3.6.1.4.1.11606.10.10.2.2.1.5No description published.
Pacific Broadband NetworksNMS-GPONNMS-GPON-MIBgponOltPonPortOpticalRxPowerRxPower1.3.6.1.4.1.11606.10.10.2.3.1.3The rx power of optical module. The unit is 0.1DBm.
Pacific Broadband NetworksNMS-IFNMS-IF-MIBtxPower31.3.6.1.4.1.11606.10.9.63.1.7.1.11The tx 3 power of optical module. The unit is 0.01DBm.
Pacific Broadband NetworksNMS-IFNMS-IF-MIBrxPower31.3.6.1.4.1.11606.10.9.63.1.7.1.12The rx 3 power of optical module. The unit is 0.01DBm.
Pacific Broadband NetworksNMS-OPTICAL-PORTNMS-OPTICAL-PORT-MIBopIfRxPowerCurr1.3.6.1.4.1.11606.10.9.183.1.1.5A unique value for each optical interface, that means optical current receive power value.
Pacific Broadband NetworksNMS-OPTICAL-PORTNMS-OPTICAL-PORT-MIBopIfTxPowerCurr1.3.6.1.4.1.11606.10.9.183.1.1.8A unique value for each optical interface, that means optical current sending power value.
Nortel (Northern Telecom, Ltd.)NORTEL-OME40G-FACNORTEL-OME40G-FAC-MIBoChRxActOcnPwr1.3.6.1.4.1.562.68.11.3.1.1.1.1.11Actual Optical Channel receive power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
Nortel (Northern Telecom, Ltd.)NORTEL-OME40G-FACNORTEL-OME40G-FAC-MIBoChTxActOcnPwr1.3.6.1.4.1.562.68.11.3.1.1.1.1.8Actual Optical Channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
Nortel (Northern Telecom, Ltd.)NORTEL-OME40G-FACNORTEL-OME40G-FAC-MIBoChTxActOtmPwr1.3.6.1.4.1.562.68.11.3.1.2.1.1.12Actual optical channel transmit power. This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
Nortel (Northern Telecom, Ltd.)NORTEL-OME40G-FACNORTEL-OME40G-FAC-MIBoChRxActOtmPwr1.3.6.1.4.1.562.68.11.3.1.2.1.1.15Actual receive power This variable is available upon GET-EXACT operations. No value is returned with GET-NEXT.
ViaLite (tentative)NSCRTV-EPON-PON-PORTNSCRTV-EPON-PON-PORT-MIBPonOpmDiagnosisTXPower1.3.6.1.4.1.17409.2.3.3.5.1.6��ģ�鷢�͹���
ViaLite (tentative)NSCRTV-EPON-PON-PORTNSCRTV-EPON-PON-PORT-MIBPonOpmDiagnosisRXPower1.3.6.1.4.1.17409.2.3.3.5.1.7��ģ����չ���
ViaLite (tentative)NSCRTV-HFCEMS-ANALOGNSCRTV-HFCEMS-ANALOG-MIBoswInputA1.3.6.1.4.1.17409.1.15.4.1.2The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB.
ViaLite (tentative)NSCRTV-HFCEMS-ANALOGNSCRTV-HFCEMS-ANALOG-MIBoswInputB1.3.6.1.4.1.17409.1.15.4.1.3The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB.
ViaLite (tentative)NSCRTV-HFCEMS-ANALOGNSCRTV-HFCEMS-ANALOG-MIBoswOutput11.3.6.1.4.1.17409.1.15.4.1.4The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB.
ViaLite (tentative)NSCRTV-HFCEMS-ANALOGNSCRTV-HFCEMS-ANALOG-MIBoswOutput21.3.6.1.4.1.17409.1.15.4.1.5The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB.
SCTENSCRTV-HFCEMS-FIBERNODENSCRTV-HFCEMS-FIBERNODE-MIBfnOpticalReceiverPower1.3.6.1.4.1.5591.1.5.5.1.2No description published.
Optical Access Inc.OA-EFRM-CPEOA-EFRM-CPE-MIBoaEfrmSfpDiagnosticTxPower1.3.6.1.4.1.6926.1.16.10.1.3.1.6Internaly measured Tx output power. Units: 0.01 decibel (dBm)
Optical Access Inc.OA-EFRM-CPEOA-EFRM-CPE-MIBoaEfrmSfpDiagnosticRxPower1.3.6.1.4.1.6926.1.16.10.1.3.1.7Internaly measured Rx input power. Units: 0.01 decibel (dBm)
Optical Access Inc.OA-SFPOA-SFP-MIBoaSfpDiagnosticTxPower1.3.6.1.4.1.6926.1.18.1.1.3.1.6Internaly measured Tx output power. Units: 0.01 decibel (dBm)
Optical Access Inc.OA-SFPOA-SFP-MIBoaSfpDiagnosticRxPower1.3.6.1.4.1.6926.1.18.1.1.3.1.7Internaly measured Rx input power. Units: 0.01 decibel (dBm)
Optical Access Inc.OA-SFPOA-SFP-MIBoaMsa300PinMeasRecSigAvrOptPower1.3.6.1.4.1.6926.1.18.1.4.3.1.7Average received optical power. Units: 0.01 decibel (dBm)
Optical Access Inc.OADWDMOADWDM-MIBoaLdOAmplifierCardOutputPower1.3.6.1.4.1.6926.1.41.12.2.1.14The Optical Amplifier Output Optical Power (in units of 1/100 [0.01 dBm])
Optical Access Inc.OADWDMOADWDM-MIBoaLdCardEntityWdmRxPm1.3.6.1.4.1.6926.1.41.4.1.1.16Transponder WDM receiver optical power. Indicates the optical power in units of 1/10 dBm. (oaLdCardEntityWdmRxPm is a signed number.) (999) is returned when this feature is not supported or irrelevant. (-999) is returned when signal is too low.
Optical Access Inc.OADWDMOADWDM-MIBoaLdCardWdmTxPm1.3.6.1.4.1.6926.1.41.3.1.1.16Transponder WDM transmitter optical power. Indicates the optical power in dBm. To calculate the power use the equation P(dBm)=oaLdCardWdmTxPm/2, when oaLdCardWdmTxPm is a signed number. (171) is returned when this feature is not supported Note: For TM-DXFP card the optical power are in units of percent (%)
GLsun Science and Tech Co. Ltd.OAP-C1-OEOOAP-C1-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.1.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C1-OLPOAP-C1-OLPc1TxPower1.3.6.1.4.1.40989.10.16.1.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C10-OEOOAP-C10-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.10.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C10-OLPOAP-C10-OLPc1TxPower1.3.6.1.4.1.40989.10.16.10.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C11-OEOOAP-C11-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.11.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C11-OLPOAP-C11-OLPc1TxPower1.3.6.1.4.1.40989.10.16.11.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C12-OEOOAP-C12-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.12.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C12-OLPOAP-C12-OLPc1TxPower1.3.6.1.4.1.40989.10.16.12.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C13-OEOOAP-C13-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.13.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C13-OLPOAP-C13-OLPc1TxPower1.3.6.1.4.1.40989.10.16.13.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C14-OEOOAP-C14-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.14.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C14-OLPOAP-C14-OLPc1TxPower1.3.6.1.4.1.40989.10.16.14.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C15-OEOOAP-C15-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.15.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C15-OLPOAP-C15-OLPc1TxPower1.3.6.1.4.1.40989.10.16.15.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C16-OEOOAP-C16-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.16.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C16-OLPOAP-C16-OLPc1TxPower1.3.6.1.4.1.40989.10.16.16.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C2-OEOOAP-C2-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.2.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C2-OLPOAP-C2-OLPc1TxPower1.3.6.1.4.1.40989.10.16.2.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C3-OEOOAP-C3-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.3.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C3-OLPOAP-C3-OLPc1TxPower1.3.6.1.4.1.40989.10.16.3.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C4-OEOOAP-C4-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.4.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C4-OLPOAP-C4-OLPc1TxPower1.3.6.1.4.1.40989.10.16.4.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C5-OEOOAP-C5-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.5.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C5-OLPOAP-C5-OLPc1TxPower1.3.6.1.4.1.40989.10.16.5.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C6-OEOOAP-C6-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.6.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C6-OLPOAP-C6-OLPc1TxPower1.3.6.1.4.1.40989.10.16.6.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C7-OEOOAP-C7-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.7.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C7-OLPOAP-C7-OLPc1TxPower1.3.6.1.4.1.40989.10.16.7.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C8-OEOOAP-C8-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.8.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C8-OLPOAP-C8-OLPc1TxPower1.3.6.1.4.1.40989.10.16.8.3.21No description published.
GLsun Science and Tech Co. Ltd.OAP-C9-OEOOAP-C9-OEOvSFPA1TxPower1.3.6.1.4.1.40989.10.16.9.2.11.4No description published.
GLsun Science and Tech Co. Ltd.OAP-C9-OLPOAP-C9-OLPc1TxPower1.3.6.1.4.1.40989.10.16.9.3.21No description published.
Omnitron Systems TechnologyOMNITRONOMNITRON-MIBportSfpTxPower1.3.6.1.4.1.7342.2.1.8.1.12SFP Transmission power in dBm
Omnitron Systems TechnologyOMNITRONOMNITRON-MIBportSfpRxPower1.3.6.1.4.1.7342.2.1.8.1.13SFP Transmission power in dBm
Optical Transmission Labs, Inc.ONS15501ONS15501-MIBons15501OutputSignalPower1.3.6.1.4.1.1869.11.11.2.5The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power
Optical Transmission Labs, Inc.ONS15501ONS15501-MIBons15501OutputSignalPowerMean1.3.6.1.4.1.1869.11.11.2.6Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (see ons15501OutputSignalPowerTrigger) an alarm is generated. The alarm is cleared when the output optical power is back within 90% of trigger from the mean.
PICA8 Inc.PICA-PRIVATEPICA-PRIVATE-MIBsfpTxPower1.3.6.1.4.1.35098.1.8.1.7The Tx power of sfp ransceiver transfer(dBm).
PICA8 Inc.PICA-PRIVATEPICA-PRIVATE-MIBsfpRxPower1.3.6.1.4.1.35098.1.8.1.8The Rx power of sfp ransceiver transfer(dBm).
Pulse Power and Measurement Ltd.PPM-IGNISPPM-IGNIS-MIBmodTx1MonLaserPower1.3.6.1.4.1.31225.1.1.4.1.1.22Tx1 Current laser power measurement, measured in 10mdBm.
B.A.T.M. Advanced TechnologiesPRVT-STATISTICS-CESPRVT-STATISTICS-CES-MIBprvtLineCurrentOPRs1.3.6.1.4.1.738.10.5.114.1.3.1.1.6Optical Power Received parameter provides a measurement of the physical layer characteristics of the incoming signal at each optical receiver.
B.A.T.M. Advanced TechnologiesPRVT-STATISTICS-CESPRVT-STATISTICS-CES-MIBprtvLineCurrentOPTs1.3.6.1.4.1.738.10.5.114.1.3.1.1.7Optical Power Transmitted parameter provides a measurement of the health of the optical transmitter.
Ericsson ABPT-SFPPT-SFP-MIBrxPower1.3.6.1.4.1.193.223.2.6.1.1.12The received light power, in dBm.
Ericsson ABPT-SFPPT-SFP-MIBtxPower1.3.6.1.4.1.193.223.2.6.1.1.13The transmit light power, in dBm.
Globalcast Communications Inc.QTECH-ALTQTECH-ALT-MIBddmDiagnosisRXPower1.3.6.1.4.1.2751.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
Globalcast Communications Inc.QTECH-ALTQTECH-ALT-MIBddmDiagnosisTXPower1.3.6.1.4.1.2751.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
QTECHQTECH-FIBERQTECH-FIBER-MIBqtechFiberRXpowerIntegerpart1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.31The integer part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Rx power value is -100(means that the value is invalid).
QTECHQTECH-FIBERQTECH-FIBER-MIBqtechFiberChannel1RXpowerIntegerpart1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.35The integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -100(means the value is invalid).
QTECHQTECH-FIBERQTECH-FIBER-MIBqtechFiberTXpowerIntegerpart1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.51The integer part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Tx power value is -100(means that the value is invalid).
QTECHQTECH-FIBERQTECH-FIBER-MIBqtechFiberChannel1TXpowerIntegerpart1.3.6.1.4.1.27514.1.1.10.2.105.1.1.1.54The integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the qtechFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -100(means the value is invalid).
QTECHQTECHQTECH-MIBddmDiagnosisRXPower1.3.6.1.4.1.27514.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
QTECHQTECHQTECH-MIBddmDiagnosisTXPower1.3.6.1.4.1.27514.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
Shanghai Meridian Technologies Co. Ltd.QTECH-NMS-IFQTECH-NMS-IF-MIBtxPower1.3.6.1.4.1.34751.9.63.1.7.1.2The tx power of optical module. The unit is 1DBm.
Shanghai Meridian Technologies Co. Ltd.QTECH-NMS-IFQTECH-NMS-IF-MIBrxPower1.3.6.1.4.1.34751.9.63.1.7.1.3The rx power of optical module. The unit is 1DBm.
Shanghai Meridian Technologies Co. Ltd.QTECH-NMS-OPTICAL-PORTQTECH-NMS-OPTICAL-PORT-MIBopIfRxPowerCurr1.3.6.1.4.1.34751.9.183.1.1.5A unique value for each optical interface, that means optical current receive power value.
Shanghai Meridian Technologies Co. Ltd.QTECH-NMS-OPTICAL-PORTQTECH-NMS-OPTICAL-PORT-MIBopIfTxPowerCurr1.3.6.1.4.1.34751.9.183.1.1.8A unique value for each optical interface, that means optical current sending power value.
QTECHQTECH-RRMQTECH-RRM-MIBqtechRrmAPIfRecommendedTxPowerLevel1.3.6.1.4.1.27514.1.1.10.2.63.1.4.11.1.2Recommended TxPowerLevel by RRM for this APIf
RAD Data Communications Ltd.RAD-GENRAD-GEN-MIBoptPrtMonitorTxPower1.3.6.1.4.1.164.6.2.15.8.1.1.3Transmitted optical power level. Value is given in units of hundredth (1/100) of dBm.
RAD Data Communications Ltd.RAD-GENRAD-GEN-MIBoptPrtMonitorRxPower1.3.6.1.4.1.164.6.2.15.8.1.1.6Received optical power in units of hundredth (1/100) of dBm.
Rapid City / Bay Networks (Avaya)RAPID-CITYRAPID-CITYrcPlugOptModTxPower1.3.6.1.4.1.2272.1.71.1.1.32This value represents the internally measured coupled TX output power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Rapid City / Bay Networks (Avaya)RAPID-CITYRAPID-CITYrcPlugOptModRxPower1.3.6.1.4.1.2272.1.71.1.1.37This value represents the internally measured received power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Rapid City / Bay Networks (Avaya)RAPID-CITYRAPID-CITYrcPlugOptModQSFPTx1Power1.3.6.1.4.1.2272.1.71.1.1.63This value represents the internally measured TX output power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
Rapid City / Bay Networks (Avaya)RAPID-CITYRAPID-CITYrcPlugOptModQSFPRx1Power1.3.6.1.4.1.2272.1.71.1.1.67This value represents the internally measured received power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).
SCTESCTE-HMS-HE-OPTICAL-AMPLIFIERSCTE-HMS-HE-OPTICAL-AMPLIFIER-MIBheOpAmpSetOpticalOutputPower1.3.6.1.4.1.5591.1.11.1.3.1.1.4.1.2Set Amplifier Optical Output Power. The setting of this value has no effect unless the heOpAmpOutputGainType is set to constantPower(1)
SCTESCTE-HMS-HE-OPTICAL-RECEIVERSCTE-HMS-HE-OPTICAL-RECEIVER-MIBheOpRxInputPower1.3.6.1.4.1.5591.1.11.1.2.1.1.1.1.2Receiver input power. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm shall be recorded as an entry in the currentAlarmTable of SCTE-HMS-PROPERTY-MIB (HMS026). A log record shall be added as an entry in the heCommonLogTable. An heCommonAlarmEvent notification shall be sent.
SCTESCTE-HMS-HE-OPTICAL-TRANSMITTERSCTE-HMS-HE-OPTICAL-TRANSMITTER-MIBheOpTxLaserOutputPower1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4The laser output power. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026). An alarm shall be recorded as an entry in the currentAlarmTable of SCTE-HMS-PROPERTY-MIB (HMS026). A log record shall be added as an entry in the heCommonLogTable. An heCommonAlarmEvent notification shall be sent.
SIAE Microelettronica S.p.A.SIAE-SFPSIAE-SFP-MIBsfpRxPower1.3.6.1.4.1.3373.1103.74.7.1.10This contains the internally measured RX optical power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). Located at I2C address 0xa2, Bytes 104 & 105 (MSB, LSB)
SIAE Microelettronica S.p.A.SIAE-SFPSIAE-SFP-MIBsfpTxPower1.3.6.1.4.1.3373.1103.74.7.1.9This contains the internally measured TX output power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). This value is not valid if the transmitter is disabled. Located at I2C address 0xa2, Bytes 102 & 103 (MSB, LSB)
PacketLight Networks Ltd.SL-EDFASL-EDFA-MIBedfaRxPower1.3.6.1.4.1.4515.1.9.1.1.1.3The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm).
PacketLight Networks Ltd.SL-SFPSL-SFP-MIBsfpConfigOptionalWdm1.3.6.1.4.1.4515.1.10.1.1.1.23The bits in the option field shall specify the options implemented in the transceiver. The following bits are defined: Bits 7: Optional Interrupt Pin Functionality Supported (1 if supported) Bits 6..4: Pilot Tone Functionality 000b: No Pilot Tone Functionality 001b: Pilot Tone Detection Only 010b: Pilot Tone Injection Only 011b: Pilot Tone Injection and Detection 100b: Enhanched Pilot Tone Functionality 101b-111b: Reserved Bits 3: Variable Optical Attenuator Implemented (1 if implemented) Bits 2: Extended Transmit Power Monitoring 0: Default (SFF-8472) TX Power Monitoring 1: Extended TX Power Monitoring (+18.2 dBm max) Bits 1: Wavelength Monitor Type in A2 Byte 106-107 0: Monitor is Wavelength 1: Monitor is Laser Temperature Bits 0: Variable Decision Threshold (1 if implemented)
PacketLight Networks Ltd.SL-SFPSL-SFP-MIBsfpDiagTxOutputPower1.3.6.1.4.1.4515.1.10.2.1.1.37Measured TX output power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor specified wavelength, accuracy shall be better than �3dB over specified temperature and voltage.
PacketLight Networks Ltd.SL-SFPSL-SFP-MIBsfpDiagRxInputPower1.3.6.1.4.1.4515.1.10.2.1.1.38Measured RX input power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor specified wavelength, accuracy shall be better than �3dB over specified temperature and voltage.
Dasan ZhoneSLE-DEVICESLE-DEVICE-MIBsleEthernetPortDMIRxPower1.3.6.1.4.1.6296.101.2.2.4.1.6Measured RX input power.
Dasan ZhoneSLE-DEVICESLE-DEVICE-MIBsleEthernetPortDMITxPower1.3.6.1.4.1.6296.101.2.2.4.1.5Measured TX output power.
Dasan ZhoneSLE-EPONSLE-EPON-MIBsleEponOltDMITxPower1.3.6.1.4.1.6296.101.20.2.7.1.1.4onu DMI txpower, range is (-40 ~ 8.1647 dBm).
Dasan ZhoneSLE-FAULTMGMTSLE-FAULTMGMT-MIBsleAdvaReceivePower1.3.6.1.4.1.6296.101.4.9.1.1.10Current receive power in dBm as reported by optics.
Dasan ZhoneSLE-FAULTMGMTSLE-FAULTMGMT-MIBsleAdvaTransmitPower1.3.6.1.4.1.6296.101.4.9.1.1.9Current transmit power in dBm as reported by optics.
Dasan ZhoneSLE-FIBERLANSLE-FIBERLAN-MIBsleFiberLanPERxPower1.3.6.1.4.1.6296.101.30.2.1.1.16PortExtender's RX power
Dasan ZhoneSLE-GPONSLE-GPON-MIBsleGponOnuOltRxPower1.3.6.1.4.1.6296.101.23.3.1.1.21Rx Optical power of olt-side.
Dasan ZhoneSLEV2-EPON-IMSLEV2-EPON-IM-MIBsleV2EponIMOnuRxOpticPower1.3.6.1.4.1.6296.102.15.1.1.1.9value of the ONU rx optical power, UNIT : dBm
SNRSNR-SWITCHSNR-SWITCH-MIBddmDiagnosisRXPower1.3.6.1.4.1.40418.7.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
SNRSNR-SWITCHSNR-SWITCH-MIBddmDiagnosisTXPower1.3.6.1.4.1.40418.7.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
Summit Development, Ltd.SummitdSummitdtxPower1.3.6.1.4.1.23688.1.1.19Actual Transmit Power [dBm]
Quanta Computer Inc.SWITCHING-EXTENSIONSWITCHING-EXTENSION-MIBagentDOMTxpower1.3.6.1.4.1.7244.2.101.1.1.108.1.5Tx Power of the transceiver module
Quanta Computer Inc.SWITCHING-EXTENSIONSWITCHING-EXTENSION-MIBagentDOMRxpower1.3.6.1.4.1.7244.2.101.1.1.108.1.6Rx Power of the transceiver module
Nokia (Alcatel-Lucent / Timetra)TIMETRA-PORTTIMETRA-PORT-MIBtmnxOpticalPortTdcmPowerIn1.3.6.1.4.1.6527.3.1.2.2.4.59.1.12The value of tmnxOpticalPortTdcmPowerIn indicates the received average optical power at the input the tunable dispersion compensation module. The UNITS millibels (mBm) are units of 0.01 decibel relative to one milliwatt (dBm) or dBm multiplied by 100. The mBm is used when integers are required instead of floating point. For example: -5.21 dBm is equivalent to -521 mBm.
Nokia (Alcatel-Lucent / Timetra)TIMETRA-PORTTIMETRA-PORT-MIBtmnxOpticalPortTdcmPowerOut1.3.6.1.4.1.6527.3.1.2.2.4.59.1.14The value of tmnxOpticalPortTdcmPowerOut indicates the optical power at the output of tunable dispersion compensation module. The UNITS millibels (mBm) are units of 0.01 decibel relative to one milliwatt (dBm) or dBm multiplied by 100. The mBm is used when integers are required instead of floating point. For example: -5.21 dBm is equivalent to -521 mBm.
Transition NetworksTN-DDMITN-DDMI-MIBtnDdmiStatusInterfaceA2CurrentTxPower1.3.6.1.4.1.868.2.5.152.1.3.2.1.1018Current Tx power in mV.
Transition NetworksTN-DDMITN-DDMI-MIBtnDdmiStatusInterfaceA2CurrentRxPower1.3.6.1.4.1.868.2.5.152.1.3.2.1.1023Current Rx power in mV.
Transition NetworksTN-MGMTTN-MGMT-MIBtnDMITxPowerLevel1.3.6.1.4.1.868.2.5.3.1.2.2.1.14DMI: Diagnostic Monitoring Interface for fiber transceivers. Transmit power on local fiber measured in microwatts.
Transition NetworksTN-MGMTTN-MGMT-MIBtnDMIRxPowerLevel1.3.6.1.4.1.868.2.5.3.1.2.2.1.16DMI: Diagnostic Monitoring Interface for fiber transceivers. Receive power on local fiber measured in microwatts.
Tropic NetworksTN-RMD-IFTN-RMD-IF-MIBtnRmdIfDdmTxOutputPower1.3.6.1.4.1.7483.6.4.1.3.7.1.16The value of tnRmdIfDdmTxOutputPower indicates the current Output Power of the interface in one tenths of a micro-Watt (uW). For example: Using the SNMP value of 790, and using units of tenths of microwatt, 790 becomes 79 microwatts or 0.079 milliwatts. Converting to dBm: 10 x log10(0.079) = -11.0 dBm
TP-Link Systems Inc.TPLINK-DDMSTATUSTPLINK-DDMSTATUS-MIBddmStatusTxPow1.3.6.1.4.1.11863.6.96.1.7.1.1.5This object indicates the tx power of the port.
TP-Link Systems Inc.TPLINK-DDMSTATUSTPLINK-DDMSTATUS-MIBddmStatusRxPow1.3.6.1.4.1.11863.6.96.1.7.1.1.6This object indicates the rx power of the port.
Trango Networks, LLCTRANGO-P5MTRANGO-P5M-MIBrfTxPower1.3.6.1.4.1.5454.1.40.2.5It specifies tx power. And it will be limited by Min/Max by different band
Tropic NetworksTROPIC-AMPLIFIERTROPIC-AMPLIFIER-MIBtnAmplifierPortOSCTxPowerOut1.3.6.1.4.1.7483.2.2.3.7.5.2.1.11The EDFA module OSC transmitted output power of the amplifier card. -9900 indicates no measured power. Current ranges: A2P2125: -1500 to 1100 AA2DONW: -1500 to 1500 AM2032A: -1500 to 1100 AM2125A: -1500 to 1100 AM2125B: -1500 to 1100 AM2318A: -1500 to 1100 AM2625A: 0 to 1500 ASWG: -1500 to 1100 A4PSWG: -1500 to 1100.
Tropic NetworksTROPIC-AMPLIFIERTROPIC-AMPLIFIER-MIBtnAmplifierPortInfoOSCRxPowerIn1.3.6.1.4.1.7483.2.2.3.7.5.2.1.22The EDFA module OSC received input power to the card. -9900 indicates no measured power.
Tropic NetworksTROPIC-AMPLIFIERTROPIC-AMPLIFIER-MIBtnAmplifierPortInfoOSCSfpTxPowerOut1.3.6.1.4.1.7483.2.2.3.7.5.2.1.23The OSCSFP transceiver output power -9900 indicates no measured power.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnOpsPortTargetReceivedPower1.3.6.1.4.1.7483.2.2.4.3.4.212.1.5Same value at A and B in ports; per channel. The SW implementation is using the Sig port to access this attribute. Current configurable range: -3150 to 1700.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnOpsPortInfoReceivedPower1.3.6.1.4.1.7483.2.2.4.3.5.191.1.1The received power in mBm. This is accessible from ports 2 and 3 (working or protected) exclusively.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnIroadmPortInfoOSCTxPowerOut1.3.6.1.4.1.7483.2.2.4.3.5.308.1.20The EDFA module OSC transmitted output power from the card. -9900 indicates no measured power. Current ranges: -9900,-1200 to 1000.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnIroadmPortInfoOSCRxPowerIn1.3.6.1.4.1.7483.2.2.4.3.5.308.1.21The EDFA module OSC received input power to the card. -9900 indicates no measured power. Current ranges: -9900,-4400 to 1000.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnIroadmPortInfoOSCSfpTxPowerOut1.3.6.1.4.1.7483.2.2.4.3.5.308.1.22The OSCSFP transceiver output power. Current ranges: -9900, -1000 to 1000.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnOtPortTxPowerLaser1.3.6.1.4.1.7483.2.2.4.3.5.71.1.5The transmit power after the MSA transponder and before the VOA.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnOtPortTxLaneBslPowers1.3.6.1.4.1.7483.2.2.4.3.5.71.1.9Displays CFP transmit lane Baseline powers for the number of lanes supported by a CFP type. Receive lane powers will not be displayed for the following conditions: - A CFP does not provide lane powers - A CFP is not equipped (not present) - A port is not provisioned. - A CFP port Total RX power is not Baselined For a CFP with 4 lanes, here is a sample output: 'TxPwr Lane 1 : -8.00 dBm TxPwr Lane 2 : -8.10 dBm TxPwr Lane 3 : -7.80 dBm TxPwr Lane 4 : -8.30 dBm' including the new line characters.
Tropic NetworksTROPIC-OPTICALPORTTROPIC-OPTICALPORT-MIBtnOtPortTxLanePowers1.3.6.1.4.1.7483.2.2.4.3.5.71.1.7Displays CFP transmit lane powers for the number of lanes supported by a CFP type. Transmit lane powers will not be displayed for the following conditions: - A CFP does not provide lane powers - A CFP is not equipped (not present) - A port is not provisioned. For a CFP with 4 lanes, here is a sample output: 'TxPwr Lane 1 : -40.00 dBm TxPwr Lane 2 : -40.00 dBm TxPwr Lane 3 : -40.00 dBm TxPwr Lane 4 : -40.00 dBm' including the new line characters.
UbiquitiUBNT-EdgeMAXUBNT-EdgeMAX-MIBubntOnuTxPower1.3.6.1.4.1.41112.1.5.6.2.1.8in hundredths of dBm
UbiquitiUBNT-EdgeMAXUBNT-EdgeMAX-MIBubntOnuRxPower1.3.6.1.4.1.41112.1.5.6.2.1.9in hundredths of dBm
v-solutionV1600DV1600DtransceiverTransmitPower1.3.6.1.4.1.37950.1.1.5.10.1.1.5.1.5No description published.
v-solutionV1600DV1600DtransceiverReceivedPower1.3.6.1.4.1.37950.1.1.5.10.1.1.5.1.6No description published.
ZyxelVES1724-58VVES1724-58V-MIBgeDdmiTxPower1.3.6.1.4.1.890.1.5.12.49.4.3.1.4Measured TX output power in 10^(-4) mW.
ZyxelVES1724-58VVES1724-58V-MIBgeDdmiRxPower1.3.6.1.4.1.890.1.5.12.49.4.3.1.5Measured RX received optical power in 10^(-4) mW.
Waystream ABWAYSTREAMWAYSTREAM-MIBwsSFPTXdBmPower1.3.6.1.4.1.9303.4.1.4.1.22Measured TX power (dBm x 1000).
Waystream ABWAYSTREAMWAYSTREAM-MIBwsSFPRXdBmPower1.3.6.1.4.1.9303.4.1.4.1.23Measured RX power (dBm x 1000).
Westermo Teleindustri ABWESTERMO-DDMWESTERMO-DDM-MIBddmPortTxPower1.3.6.1.4.1.16177.2.2.1.1.1.6Transmit power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm.
Westermo Teleindustri ABWESTERMO-DDMWESTERMO-DDM-MIBddmPortRxPower1.3.6.1.4.1.16177.2.2.1.1.1.7Receiving power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm.
Westermo Teleindustri ABWESTERMO-WEOSWESTERMO-WEOS-MIBsfpDdmPortTxPower1.3.6.1.4.1.16177.2.1.2.2.1.1.6Transmitt power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm
Westermo Teleindustri ABWESTERMO-WEOSWESTERMO-WEOS-MIBsfpDdmPortRxPower1.3.6.1.4.1.16177.2.1.2.2.1.1.7Receiving power of the laser. The accuracy is better than +/-3dB and the total range of -40 to +8.2 dBm ~(0 - 6.5535 mW). The power is represented in steps of 0.01 dBm
CERNWR-SWITCHWR-SWITCH-MIBwrsPortStatusSfpTxPower1.3.6.1.4.1.96.100.7.6.1.20Measured TX output power in uW reported by SFP. According to SFF-8472, accuracy of this value must be better than 3dB%
CERNWR-SWITCHWR-SWITCH-MIBwrsPortStatusSfpRxPower1.3.6.1.4.1.96.100.7.6.1.21Measured RX output power in uW reported by SFP. According to SFF-8472, accuracy of this value must be better than 3dB%
Ciena (World Wide Packets)WWP-LEOS-PORT-XCVRWWP-LEOS-PORT-XCVR-MIBwwpLeosPortXcvrRxDbmPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.105Indicates the Rx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Ciena (World Wide Packets)WWP-LEOS-PORT-XCVRWWP-LEOS-PORT-XCVR-MIBwwpLeosPortXcvrTxDbmPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.106Indicates the Tx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Ciena (World Wide Packets)WWP-LEOS-PORT-XCVRWWP-LEOS-PORT-XCVR-MIBwwpLeosPortXcvrRxPower1.3.6.1.4.1.6141.2.60.4.1.1.1.1.19This represents the measured receive power of the transceiver. Units are micro Watts.
National Center for Software Technology (India)XXXXXX-MIBmc2-5g-sfpTranPower1.3.6.1.4.1.6688.1.1.1.4.2.10.1.1.1.11SFP tx power (one type, signed)
National Center for Software Technology (India)XXXXXX-MIBmc2-5g-sfpRecvPower1.3.6.1.4.1.6688.1.1.1.4.2.10.1.1.1.12SFP rx power (one type, signed)
ZelaxZELAXZELAX-MIBddmDiagnosisRXPower1.3.6.1.4.1.7840.2.1.100.30.1.1.17RXPower of the port,and the unit is dBM,if the value of RXPower is infinitesimal,then set it to '-'.
ZelaxZELAXZELAX-MIBddmDiagnosisTXPower1.3.6.1.4.1.7840.2.1.100.30.1.1.22TXPower of the port,and the unit is dBM,if the value of TXPoweris infinitesimal,then set it to '-'.
Zhone TechnologiesZHNGPONLINKZHNGPONLINKtxPower1.3.6.1.4.1.5504.2.5.43.1.2.1.8GPON interface transmit power, in dBm.
Zhone TechnologiesZHNHPNAZHNHPNAhpnaStationRxPower1.3.6.1.4.1.5504.2.5.47.1.3.1.7HPNA receive power, in dBm.
Zhone TechnologiesZHNHPNAZHNHPNAhcnaStationRxPower1.3.6.1.4.1.5504.2.5.47.1.4.1.7HCNA receive power, in dBm.
Zhone TechnologiesZhone-GPONZhone-GPON-MIBzhoneGponOltOpticTxPower1.3.6.1.4.1.5504.5.14.1.20.1.4Measured Tx Output Power of the OLT in dB. The measured value will be in tenths of dB.
Zhone TechnologiesZhone-GPONZhone-GPON-MIBzhoneGponOntRxPower1.3.6.1.4.1.5504.5.14.1.7.1.4Rx Power as reported by the ONT. The value is in tenths of dB.
Zhone TechnologiesZHONE-SFFZHONE-SFFzhoneDDMTxPower1.3.6.1.4.1.5504.3.12.1.3.1.4Measured Tx output power.
Zhone TechnologiesZHONE-SFFZHONE-SFFzhoneDDMRxPower1.3.6.1.4.1.5504.3.12.1.3.1.5Measured received power.
ZTE (Zhongxing Telecom)ZXR10-OPTICAL-ALARMZXR10-OPTICAL-ALARM-MIBzxr10opticalTxPower1.3.6.1.4.1.3902.3.126.1.2.1.3No description published.
ZTE (Zhongxing Telecom)ZXR10-OPTICAL-ALARMZXR10-OPTICAL-ALARM-MIBzxr10opticalRxPower1.3.6.1.4.1.3902.3.126.1.2.1.4No description published.
ZyxelZYXEL-IES5000ZYXEL-IES5000-MIBsfpTxPower1.3.6.1.4.1.890.1.5.13.5.13.13.2.1.12No description published.
ZyxelZYXEL-ves1724-56-FanlessZYXEL-ves1724-56-Fanless-MIBtxPower1.3.6.1.4.1.890.1.5.12.47.35.7.2.1.1.7Transmit power 1: 30 mW 2: 15 mW
ZyxelZYXEL-ves1724-56ZYXEL-ves1724-56-MIBtxPower1.3.6.1.4.1.890.1.5.12.46.35.7.2.1.1.7Transmit power 1: 30 mW 2: 15 mW